background image

SBN Pendant Station Manual 

October 2019 

Page 5 of 19 

Preface and Safety

©2016 MAGNETEK 

All rights reserved. This notice applies to all copyrighted materials included with this product, including, 

but not limited to, this manual. This manual is intended for the sole use of the persons to whom it was 

provided, and any unauthorized distribution of the manual or dispersal of its contents is strictly forbidden. 

This manual may not be reproduced in whole or in part by any means whatsoever without the expressed 

written permission of Magnetek. 

Product Safety Information 

Magnetek, Inc. (Magnetek) offers a broad range of radio remote control products, control products and 

adjustable frequency drives, industrial braking systems, and power delivery products for material handling 

applications. This manual has been prepared by Magnetek to provide information and recommendations 

for the installation, use, operation and service of Magnetek’s material handling products and systems 

(Magnetek Products). Anyone who uses, operates, maintains, services, installs or owns Magnetek 

Products should know, understand and follow the instructions and safety recommendations in this manual 

for Magnetek Products. 

The recommendations in this manual do not take precedence over any of the following requirements 

relating to cranes, hoists, lifting devices or other equipment which use or include Magnetek 

Products: 

x

  Instructions, manuals, and safety warnings of the manufacturers of the equipment where the 

Magnetek Products are used, 

x

  Plant safety rules and procedures of the employers and the owners of the facilities where the 

Magnetek Products are being used, 

x

  Regulations issued by the Occupational Health and Safety Administration (OSHA), 

x

  Applicable local, state, provincial, or federal codes, ordinances, standards and requirements, or 

x

  Safety standards and practices for the industries in which Magnetek Products are used. 

This manual does not include or address the specific instructions and safety warnings of these 

manufacturers or any of the other requirements listed above. It is the responsibility of the owners, users 

and operators of the Magnetek Products to know, understand and follow all of these requirements. It is 

the responsibility of the employer to make its employees aware of all of the above listed requirements and 

to make certain that all operators are properly trained.  

No one should use Magnetek Products prior to becoming familiar with and being trained in these 

requirements and the instructions and safety recommendations for this manual. 

Product Warranty Information 

Magnetek, hereafter referred to as Company, assumes no responsibility for improper programming of a 

device (such as a drive or radio) by untrained personnel.  A device should only be programmed by a 

trained technician who has read and understands the contents of the relevant manual(s).  Improper 

programming of a device can lead to unexpected, undesirable, or unsafe operation or performance of the 

device.  This may result in damage to equipment or personal injury.  Company shall not be liable for 

economic loss, property damage, or other consequential damages or physical injury sustained by the 

purchaser or by any third party as a result of such programming.  Company neither assumes nor 

authorizes any other person to assume for Company any other liability in connection with the sale or use 

of this product. 

For information on Magnetek’s product warranties by product type, please visit www.magnetek.com. 

Summary of Contents for SBIT-8-W

Page 1: ...SBN Pendant Pushbutton Station Instruction Manual Part Number 126 11173 R2 October 2019 Copyright 2019 Magnetek Material Handling...

Page 2: ...Page Intentionally Left Blank...

Page 3: ...10 Precautions for Wiring 10 Enclosure disassembly 11 Wiring 11 Enclosure Reassembly 12 Strain Relief Installation when using cable with molded in strain relief cables 13 Strain Relief Installation w...

Page 4: ...r technical information contact Magnetek Material Handling N49 W13650 Campbell Drive Menomonee Falls WI 53051 Distributed by Tri State Equipment Company Inc Telephone 314 869 7200 Website E mail Fax N...

Page 5: ...x Regulations issued by the Occupational Health and Safety Administration OSHA x Applicable local state provincial or federal codes ordinances standards and requirements or x Safety standards and prac...

Page 6: ...hazardous situation which if not avoided will result in death or serious injury This signal word is to be limited to the most extreme situations WARNING WARNING indicates a potentially hazardous situa...

Page 7: ...of the pendant housing is possible Contaminants that enter the switch contacts may result in a potentially unsafe operating condition When cutting stripping and installing wires ensure that contaminan...

Page 8: ...SBN Pendant Station Manual October 2019 Page 8 of 19 Product Overview and Features Figure 1 SBN 8 WHS Pendant...

Page 9: ...ainless steel cover screws and molded in cover nuts x External key ring for strain relief cable attachment x Internal strain relief clamp x Pre wired common circuit x NEMA 4X rating see Table 1 for NE...

Page 10: ...and proper lockout tagout procedures followed DO NOT make or break electrical connections for example plugs and receptacles without first disconnecting power at the source and following proper lockou...

Page 11: ...land like a hat when wiring is complete This is an additional cover for the gland cable connection that can provide extra protection against water intrusion It should be trimmed with scissors in a sin...

Page 12: ...cting the water and would be able to conduct current away Using a ground fault circuit would alert the control system to the abnormal condition Enclosure Reassembly 1 Ensure that there are no bare or...

Page 13: ...ey ring in the top of the pendants and back through the strain relief collars Tighten the set screws until the strain relief cables are secure Trim off the strain relief wires so they are flush with t...

Page 14: ...legend and replace with the selected word or symbol from the legend sheet Insert the lens over the legend and make sure it is secure Button Hood Replacement Remove the switch under the button hood by...

Page 15: ...ove any dirt from the outside of the pendant x Ensure that the cable is not cut or damaged x Ensure that the cable entry point is well sealed x Ensure that there are no cracks cuts or openings in the...

Page 16: ...or the operator and the load is clear x Face the load and stand such that it moves away from you Do not touch the load when it is being lifted x Stay far enough away from a load so that if it drops it...

Page 17: ...e armor provides a steadfast seal For example if preparing cable armor for an SBN 2 W the type of cable armor the unit should come with is Type A The outer diameter of the cable is 11mm so the cable a...

Page 18: ...tion Manual October 2019 Page 18 of 19 Appendix B Pendant Switch Schematics Distributed by Tri State Equipment Company Inc Email sales tsoverheadcrane com Web www tsoverheadcrane com PH 314 869 7200 F...

Page 19: ...SBN Pendant Pushbutton Station Instruction Manual October 2019...

Reviews: