2.6. System
Specifications
Specification Laser
Laser Support Unit (LSU)
LG2-H-4 LG2-L-4 LG2-H-4X
LG2-L-4X
Operating
Temperature
-30° to 55°C
-30° to 70°C
Operating Range
8 in.-150 ft.
--
--
--
--
Input Voltage
--
85 - 264 VAC or
120 - 370 VDC
9-36 VDC
85 - 264 VAC or
120 - 370 VDC
9-36 VDC
Accuracy 1
in.
--
Hysteresis --
Approx.
12”
Control Outputs
--
Three form C relays rated at 10 A, 270 VAC, and 27 VDC
Fault Output
--
One form C relay rated at 10 A, 270 VAC, and 27 VDC
Laser Class
1
--
Wavelength 660
nm
Ambient Light
Limit
50000 Lux
--
Enclosure
(Standard)
Plastic IP65
NEMA 4
NEMA 4X
Unit Dimensions
4.0” x 2.1” x 1.0”
Approx. 11.8” x 9.8” x 5.9”
Weight
0.2 lbs.
Approx. 12.2 lbs.
Reflector
Dimensions
2’ x 2’
--
Cable Length
32.8 ft.
(standard)
--