Flex EM/EX HazLoc Transmitter Instruction Manual
January 2018
7 Troubleshooting
7.1 Troubleshooting Table
Problems
Possible Reasons
Suggestions
No response when transmitter push
button is pressed (Improper startup
and settings)
Transmitter low
battery power
Check the transmitter battery level.
Emergency stop
button activated
prior to startup
Prior to turning on the transmitter
power switch, make sure that the red
emergency stop button is elevated.
Improper startup
procedure
Repeat the startup procedure by
holding the power key at START
position for up to 2.0 seconds and
then release.
Incorrect system
RF channel
Make sure that the transmitter
handset and the receiver unit both
have the same channel.
Incorrect Receiver
Access Code
Make sure that the transmitter
handset and receiver unit both have
the same Receiver Access Code.
System out of
range
Make sure that the startup procedure
is initiated within 100 meters (300
feet) from the receiver location.
WARNING
The operator should not attempt to repair any radio controller. If any product performance or safety
concerns are observed, the equipment should immediately be taken out of service and be reported to
the supervisor. Damaged and inoperable radio controller equipment should be returned to Magnetek
for evaluation and repair. Failure to follow this warning could result in serious injury or death and
damage to equipment.