background image

GO

Threshold value

NOGO

Standard

Workpiece 

Workpiece 2

GO

Threshold value = Middle of the 
 

workpieces 1 and 2

NOGO

Workpiece

1

Standard 

Workpiece

Setting is Completed

Setting is Completed

Setting is Completed

Setting is Completed

Moving the finger off the button displays "2Pnt". 

Workpiece setting

Upper Limit 

Workpiece

Workpiece setting

2-2  

Switching Control Output

2-3  

Reference Point

2-5  

Minute Adjustment of Threshold Level

2-4  

Tolerance Judgment

NO/NC

Under NO (Normal Open) setting, the 
output turns on when a workpiece is 
within the tolerance (GO).

            of [NO/NC Indicator] turns ON.

Under NC (Normal Close) setting, the output 
turns on when a workpiece is outside the 
tolerance (NoGO).

            of [NO/NC Indicator] turns ON.

Measuring Unit Connection 
Side Hook

Under [Detection Mode], press and hold        button.
The threshold value blinks.

<<For Area Detection Mode Setting>>

1.
2.

Error / Display / Cause

Remedy

Error Origin Tuning Type

Overflow Error

1-2

  

Input/Output Circuit Diagram

1-4  

Mounting the Measuring Unit

1-3  

Mounting the Digital Tolerance Indicator

*

 Fix the cable in a suitable position to prevent possible cable breakage.

*

 Fix the cable in a suitable position to prevent possible cable breakage.

2-1  

Setting and Display Overview

[NO/NC Indicator: Orange] 

Indicates current NO/NC setting.

[GO Indicator Orange]

Turns ON when judged as

GO. The up/down arrows 

on the right indicate 

HIGH/LOW judgment result. 

[Preset Indicator: Green]

[ST Indicator: Blue]

Turns ON when Tolerance setting is in progress.

Displays the measured value.

Indication is in 0.1

μ

m step.

Minute Threshold Adjustment

[UP/DOWN] Button

Changes a threshold value. During the area setting, H or L is

displayed on the left of the threshold value you are setting, 

allowing identification of HIGH or LOW threshold value that 

is being set 

Mode/OUT Switch

[MODE] Button
Switches the threshold value to set by short pressing to HIGH or 

LOW. Pressing and holding for 3 seconds or longer switches 

between setting and detection modes.

Output Switch

[NO/NC] Button

Switches the polarity of the 

external output. 

When reference point use setting is ON (See 3 Convenient
Setting Features)
The measured value is not displayed until the measuring 
unit passes the reference point after power ON.
When the reference point is used, turn on the power with 
the spindle extended as far as possible, and then move 
the spindle 1.5 mm or more. 

Tolerance Setting Button

[ST] Button

Allows threshold 

setting based on 

the workpiece.

Turns ON when preset has been set.

2-point area setting 

Setting for sensing within the range of the upper and lower limits (Threshold 2-point)  

± tolerance setting

Measuring a workpiece with 

± 

tolerance (Threshold 2-point)  

2-point setting

Measuring for one reference (Threshold 1-point)

1.  Select [Setting Mode] 

 [Tolerance Setting : HIGH] and configur e the tolerance value on the High end.

2.  Select [Tolerance Setting : LOW] and configure the tolerance value on the Low end.
3.  Select [Area detection Mode] in [Judgment Output Mode]
4.  Press and hold the [MODE] button for 3 seconds or longer to exit the Setting Mode.
5.  Follow the procedure below and make the settings.

1.  Select [Normal Detection Mode] after the process of following [Setting Mode]

[Judgment Output Mode]

2.  Press and hold the [MODE] button for 3 seconds or longer to exit the Setting Mode.
3.  Follow the procedure below and make the settings.

1.  Select [Normal detection Mode] after the process of following [Setting Mode]

[Judgment Output Mode]

2.  Press and hold the [MODE] button for 3 seconds or longer to exit the Setting Mode.
3.  Follow the procedure below and make the settings.

Threshold value HIGH :  Upper Limit Workpiece Height
Threshold value LOW  :  Lower Limit Workpiece Height

Threshold value HIGH :  Preset value + Tolerance setting (HIGH)
Threshold value LOW  :  Preset value - Tolerance setting (LOW)

*

Under normal direction

*

Under normal direction

Threshold value setting: Set the value in the middle between the measured values for the 1st and 2nd points.

Workpiece setting

Workpiece

1

Workpiece 2

Near Error

The difference between the 1st and 

the 2nd measured values is too small.

·   Ensure the wider distance between the 1st and the 
  2nd measuring  points.
·   Set the larger difference between the tolerance 
  settings of HIGH and LOW.
·   For hysteresis setting, con

fi

gure a smaller setting value.

·   Con

fi

gure the preset value again.

·   Con

fi

gure the tolerance setting again.

·   For hysteresis setting, con

fi

gure a smaller setting value.

·   Con

fi

gure the preset value again.

·   Con

fi

gure the tolerance setting again.

The preset or tolerance 

setting value is too large.
Underflow Error

·   Con

fi

gure the preset value again.

·   Con

fi

gure the tolerance setting again.

Tolerance Judgment Error

The 1st and the 2nd measuring points are 

close, or tolerance setting is too small.

The preset or tolerance 

setting value is too small.

· HIGH Threshold Value Display

1-1  

Dimensions

Workpiece setting

1-point setting

Measuring for standard workpiece as reference (Threshold 1-point)

Threshold setting:  Set the workpiece value as the threshold.

Standard 

Workpiece

Release the button when "1 Pnt" flashes

MODE

MODE

· LOW Threshold Value Display

MODE

· Measured Value Display

<<For Normal Detection Mode Setting>>

MODE

· Measured Value Display

· Threshold Value Display

Setting Error

Pressing and holding the button allows quick setting. To manually set threshold values, always con

fi

gure them so that "HIGH

threshold value > LOW threshold value". If they are con

fi

gured as "HIGH threshold value < LOW threshold value"; 

- GO judgment is not given regardless of a measured value.
- HIGH and LOW indicators turn ON at the same time and error output is provided if the judgment result is other than HIGH/LOW.

The threshold level becomes higher.

The threshold level becomes lower.

Release the button when "toL" flashes

Threshold Value HIGH
Threshold Value LOW

Tolerance 

setting (HIGH)

Tolerance 

setting (LOW)

Threshold value HIGH

Threshold value LOW

Setting as preset value

Unit: mm

Dimensions in parentheses ( ) indicates the ones with related components.
The cover could come off if it is tilted by 170 degrees or more.

167.8 (Max. with the protective cover open)

170° (Max. with the protective cover open)

11

4 (Max.

 with the pr

ot

ectiv

co

ver open)

 

Mounting on DIN Track

1.  Let the hook on the digital tolerance indicator’s measuring unit 
 

connection side catch the track.  

2.   Push the unit until the hook clicks into place.

 

Removing from DIN Track

1.   Push the unit in the direction 1.
2.   Lift the unit in the direction of arrow 2 while performing 
 step 

(1).

 

When used in a row

·  Up to 30 digital tolerance indicators can be installed in a row.
  

Press     button.

Hold for 3 seconds or longer

Hold for 3 seconds or longer

3.

UP/DOWN

Press            button to adjust
the threshold level. 

Upper Limit 

Workpiece

Workpiece

 

MF10-P1 (NPN type)

 

MF10-P2 (PNP type)

PRECAUTIONS ON SAFETY

Meanings of Signal Words

Warning Indications

PRECAUTIONS

Indicates a potentially hazardous situation which, if not avoided, 
may result in minor or moderate injury or in property damage. 

Do not use the product with voltage in excess of the rated voltage.
Excess voltage may result in malfunction or fire.

Never use the product with an AC power supply. Otherwise, 
explosion may result. 

CAUTION

PRECAUTIONS FOR SAFE USE

PRECAUTIONS FOR CORRECT USE

Checking the Package Content

10 to 30 VDC

0V

PLC, etc.
(Operating current
1 mA max.)  

Brown

Pink

External Input

Blue

Black:

Control Output 1
Orange:

Control Output 2

3.3VDC

Load

Load

Overcurrent Protection Circuit

Main Circuit

10 to 30 VDC

0V

PLC, etc.
(Operating current
3 mA max.)  

Brown

Pink

External 

Input

Blue

Black:

Control Output 1

Orange:

Control Output 2

Load

Overcurrent Protection Circuit

Main Circuit

Load

The following precautions must be observed to ensure safe operation of the product. Doing so 
may cause damage or 

fi

re.

 Installation Environment

·  Do not use the product in environments subject to 

fl

ammable or explosive gases.

·  To secure the safety of operation and maintenance, do not install the product close to 

high-voltage devices and power devices.

·  Do not use the product in any atmosphere or environment that exceeds the ratings.
·  Do not use the product in environments subject to exposure to water, oil, chemicals, etc.

 Power Supply and Wiring

·  Do not impose voltage exceeding the rated voltage: 10 to 30 VDC, including 10% ripple (p-p).
·  Do not apply voltages or currents that exceed the rated ranges.
·  When supplying power to the product, make sure that the polarity of the power is correct, 

and do not connect to an AC power supply.

·  Do not miswire such as the polarity of the power supply.
·  Do not apply any load exceeding the ratings.
·  Connect the load correctly.
·  Do not short both ends of the load.
·  Do not short-circuit the open collector output load.
·  Be sure to turn OFF the power when you plug/unplug the connector with the measuring 

unit, connect/disconnect with the digital tolerance indicator, or add digital tolerance 
indicators.

·  High-Voltage lines and power lines must be wired separately from this product. Wiring 

them together or placing them in the same duct may cause induction, resulting in 
malfunction or damage.

 Installation

·  Do not install the product in locations subjected to strong magnetic 

fi

eld or electric 

fi

eld.

 Others

·  Do not attempt to disassemble, repair, or modify the product in any way.
·  Do not use the product if the case is damaged.
·  When disposing of the product, treat it as industrial waste.
·  When making setting, be sure to check safety such as by stopping the equipment.

 Installation Location

·  Do not install the product in the following locations.
(1) Locations subject to direct sunlight
(2) Locations subject to condensation due to high humidity
(3) Locations subject to corrosive gas
(4) Locations subject to vibration or mechanical shocks exceeding the rated values
(5) Place where there are dusts, salt contents or iron powders

 Power Supply and Wiring

·  It may take time for the measurement to stabilize right after the power is turned ON, 

depending on the environment.

·  Output pulses may occur when the power supply is turned OFF. Turn OFF the power supply 

to the load or load line 

fi

rst.

·  The product is ready to operate 1.5s after the power supply is turned ON. If the digital 

tolerance indicator and load are connected to power supplies separately, turn ON the power 
supply to the product 

fi

rst.

·  Be sure to turn OFF the power when you plug/unplug the connector with the measuring unit, 

connect/disconnect with the digital tolerance indicator, or add digital tolerance indicator.

·  Extended length on the digital tolerance indicator end must be up to 30 m. For extension, use a 

cable with 0.3 mm

2

 larger.

 Installation

·  Do not apply the forces on the cord exceeding the following limits:Pull: 40 N; torque: 0.1 N·m; 

pressure: 20 N; bending: 3 kg

·  Do not pull or twist the measuring unit connector with excessive force when it is fixed to the 

digital tolerance indicator. (9.8 N or less)

 Others

·  Always keep the protective cover in place when using the product. Not doing so may cause 

malfunction.

·  Do not use thinner, benzine, acetone, and lamp oil for cleaning.

·  Digital tolerance indicator: 1      ·  Instruction Sheet (this sheet)

Settings

Installation

*

 Also see “5. Detailed Settings” when making the settings.

1.  Select [Area detection Mode] after the process of following [Setting Mode]

[Judgment Output Mode]

2.  Press and hold the [MODE] button for 3 seconds or longer to exit the Setting Mode.
3.  Follow the procedure below and make the settings.

Lower Limit Workpiece

1

1.  Open the protection cover.
2.  Insert the measuring unit, with the lock lever on its 

connector area facing upward, all the way into the 
connector port.

To remove it, press and hold the lock lever then pull 
the measuring unit out.   

1.5 mm or 

more

ST

Digital Tolerance Indicator

Instruction Manual

Read all the instructions in the manual carefully before use and strictly follow them.

Keep the manual for future references.

MF10-P1/MF10-P2

MF10-P1/MF10-P2

1

2

2

1

Lock Lever

[For U.S.A. and Canada]

THIS CLASS A DIGITAL DEVICE COMPLIES WITH PART15 OF THE FCC RULES 
AND THE CANADIAN ICES-003. OPERATION IS SUBJECT TO THE FOLLOWING 
TWO CONDITIONS.
(1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND 
(2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING 

INTERFERENCE THAT MAY CAUSE UNDERSIGNED OPERATION.

CET APPAREIL NUMÉRIQUE DE LA CLASSE A EST CONFORME À LA NORME 
NMB-003 DU CANADA.

2

GO
LOW

HIGH

Lower Limit Workpiece

GO

LOW

HIGH

Workpiece

ST

ST

ST

ST

ST

3.4

2.6

32.1

83.4

Ø4

12.7

33.5

30.2

5.2

4.2

27.8

10

6.9

10

(49.5)