Error Code List
No
Error Code
Description
1
Chain 1 error
The gap between two notes is under 100mm.
2
Chain 2 error
After note passes counter sensor, note length is over 100mm.
3
JAM 1 error
Encoder value isn’t increased although motor turns.
4
JAM 2 error
Because note places on Counter sensor and motor is kept turning ticking
over, length information is increased.
5
JAM 3 error
Note is not moved to upside when motor turns counter direction.
6
Motor error
Motor isn’t controlled properly.
7
Double error
Thickness by measuring IR is lower than the standard.
8
Half error
Only half of note is recognized.
9
MinSize error
Note size is smaller than the minimum size.
10
SKEW error
The difference between R and L is over 10 mm.
11
Rotate error
Note is rotated over an angle of 20 degrees.
12
XSize error
X size of note is not matched. (CIS sensor information)
13
YSize error
Y size of note is not matched. (Cnt sensor information)
14
IR 1 error
IR error
15
Color 1 error
Color error
16
UV 1 error
UV error
17
MG 1 error
MG error
18
Differ value
Counted note is not matched with the selected denomination.
19
Differ version
Version is different with the set version.