Maintenance
Preventive Maintenance
4
MagneMotion
Rockwell Automation Publication MMI-UM002E-EN-P - March 2016
Puck Cleaning
The pucks used on the MagneMover LITE transport system may need to be cleaned to remove
any particulate buildup on the wear surfaces of the pucks.
Required Tools and Equipment
•
Disposable gloves.
•
Microfiber cleaning cloth.
•
Deionized water.
•
Isopropyl alcohol.
Procedure
1.
Remove the puck from the MagneMover LITE transport system (refer to
2.
While wearing gloves, clean internal puck wear surfaces with a clean cotton tipped
swab slightly dampened with isopropyl alcohol (squeezing the swab should not cause
any alcohol to drip) by running the swab between the top and center plates using a
back-and-forth motion in the direction of travel (refer to
).
Figure 7-1: Puck Cleaning
3.
While wearing gloves, clean external puck wear surfaces with a clean microfiber cloth
slightly dampened with isopropyl alcohol (squeezing the cloth should not cause any
alcohol to drip) by running the cloth over the surfaces in the direction of travel (refer
to
).
4.
While wearing gloves, dry all cleaned puck surfaces with a clean dry clean cotton
tipped swab and a clean dry microfiber cloth.
5.
Replace the puck on the MM LITE transport system (refer to
Internal Wear
External Wear
Surfaces