Design Guidelines
Transport System Options
MagneMover LITE User Manual
43
Rockwell Automation Publication MMI-UM002E-EN-P - March 2016
Precision Locator Installation
The Precision Locator is designed to be installed using the locator stand.
shows
the critical dimensions for the installation.
Figure 3-29: Precision Locator Installation Dimensions
Once the Precision Locator is installed the location for the pallet at the Precision Locator sta-
tion must be taught to ensure the pallet is properly secured by the locator. Then, the location of
the pallet while it is secured must be taught to the interfacing equipment.
NOTE:
Replacement of the locator stand may require reteaching of the pallet location.
Pneumatic Piping
The Precision Locator is designed to operate at a nominal 2.03 cc
3
/sec @ 0.41 mPa
[0.0043 scfm @ 60 psi] per cycle @ 21° C [70° F] @ sea level. The compressed air system
and piping to the locator(s) must be designed to support this requirement. A pneumatic block
diagram for the Precision Locator using a 5/2 valve is provided in
182.1
FIXTURE PLATE
THICKNESS
8MM (5/16")
2X 37.5
Locator Stand
Adjustable Motor Mount