background image

6

Window Installation Kit

Press the exhaust hose into the window slider adaptor and unit adaptor, 

clamps automatically by elastic buckles of the adaptors.

Step One: Preparing the Exhaust Hose assembly

Step Two: Install the Exhaust hose assembly to the unit 

Step Three: Preparing the Adjustable Window Slider

1. Depending on the size of your window, adjust the size of the 

    window slider. 

 

2. If the length of the window requires two window sliders, use the bolt

    to fasten the window sliders once they are adjusted to the proper

    length.

Window slider A

Window slider B

Bolt

Insert unit adaptor of the Exhaust hose assembly into the lower groove 

of the air outlet of the unit while the hook of the adaptor is aligned with 

the hole seat of the air outlet and slide down the Exhaust hose assembly 

along the arrow direction for installation.

Hook

Hole Seat

Lower groove

adaptor

Make sure the adaptor is inserted into the lower 

groove of the air outlet. 

Unit adaptor Window slider

adaptor

Exhaust hose

Exhaust hose 

assembly

Installation

Tools Needed

-Medium Philips screwdriver; -Tape measure or ruler; -Knife or scissors; 

-Saw (optional, to shorten window adaptor for narrow windows) 

Accessories

 

Part

Description

1 pc
1 pc
1 pc

1 pc
1 pc
1 pc

1 pc

1 pc

2 pc
2 pc

1 set

1 set

Unit Adaptor 

Window Slider Adaptor

Window Slider A
Window Slider B

Exhaust Hose

Bolt

Foam Seal A (Adhesive)
Foam Seal B (Adhesive)
Foam Seal C (Non-adhesive)

Security Bracket and 2 Screws
Drain Hose

Quantity

 Remote Control and Battery

(For remote control models only)

O

N

/O

FF

TE

M

P

SH

OR

T

   C

UT

TI

M

ER

  O

N

TI

M

ER

  O

FF

M

OD

E

FA

N

SL

EE

P

SW

IN

G

LE

D

 

Your Window Installation Kit fits windows 26.5-48” (67.5-123cm) and can 

be shortened for smaller windows. 

Summary of Contents for P-08NPE

Page 1: ...For any service needs call 1 855 368 8606 OWNER SMANUAL MODEL P 08NPE P 12NPE P 14NPE...

Page 2: ...Contents 1 Preparation 2 Precautions Cautions Installation Operation 9 Maintenance Faults Diagnosis Design and Unit Temperature Range Safety 3 4 5 12 13 14...

Page 3: ...orizontal louver blade Caster power plug socket power cord buckle bottom tray drain outlet power cord outlet drain outlet only for pump heating mode upper air filter behind the grille upper air intake...

Page 4: ...o mitigate safety hazards DO NOT modify the length of the power cord or use an extension cord to power the unit DO NOT share a single outlet with other electrical appliances Improper power supply can...

Page 5: ...ith throw rugs runners or similar coverings Do not route cord under furniture or appliances Arrange cord away from traffic area and where it will not be tripped over Do not operate unit with a damaged...

Page 6: ...d 5 Your installation location should meet the following requirements Make sure that you install your unit on an even surface to minimize noise and vibration The unit must be installed near a grounded...

Page 7: ...let and slide down the Exhaust hose assembly along the arrow direction for installation Hook Hole Seat Lower groove adaptor Make sure the adaptor is inserted into the lower groove of the air outlet Un...

Page 8: ...between the glass and the window frame to prevent air and insects from getting into the room If desired install the security bracket with 2 screws as shown Insert the window slider assembly into the w...

Page 9: ...e hose Make sure that there is no obstacle around the air outlet of the exhaust hose in the range of 19 69inch in order for the exhaust system works properly All the illustrations in this manual are f...

Page 10: ...t illuminates under the timer on off settings Mode button Selects the appropriate operating mode Each time you press the button a mode is selected in a sequence that goes from AUTO COOL DRY and FAN Th...

Page 11: ...lay it will stay like this until the unit is drained if this happens you should drain the water from the lower drain located at the bottom of the unit The top drain is used only if you choose DRY mode...

Page 12: ...feature The louver will swing up and down automatically Please do not adjust the louver manually Water drainage During dehumidifying modes remove the upper drain plug from the back of the unit instal...

Page 13: ...mold In households with animals you will have to periodically wipe down the grill to prevent blocked air ow due to animal hair Remove the air filter Upper filter take out lower filter B take out lowe...

Page 14: ...nnected or is blocked The Water Collection Tray is full Turn off the unit drain the water from the Water Collection Tray and restart the unit There are heat sources inside the room Turn off the unit a...

Page 15: ...order to ensure the optimal performance of our products the design speci cations of the unit and remote control are subject to change without prior notice Unit Temperature Range 14 Cool 17 35 C 62 95...

Page 16: ......

Reviews: