1-7-5
T2202EA
9. Focus Adjustment
Purpose:
Set the optimum Focus.
Symptom of Misadjustment:
If Focus Adjustment is
incorrect, blurred images are shown on the display.
Note:
Focus VR --- FBT (Sub CBA),
FBT = Fly Back Transformer
1. Operate the unit more than 30 minutes.
2. Face the unit to the East and degauss the CRT
using a degaussing coil.
3. Input the monoscope pattern.
4. Adjust the Focus Control on the FBT to obtain a
clear picture.
10. H. Position Adjustment
Purpose:
To obtain correct horizontal position of
screen image.
Symptom of Misadjustment:
H. position may not be
properly displayed.
1. Enter the Service mode. (See page 1-7-1.)
Press [8] button on the remote control unit and
select H-P mode.
2. Input monoscope pattern.
3. Press [CH.
o
/
p
] buttons on the remote control
unit so that the left and right side of the
monoscope pattern are equal to each other.
11. V. Shift Adjustment
Purpose:
To obtain correct vertical position of screen
image.
Symptom of Misadjustment:
If V. position is
incorrect, vertical position of image on the screen may
not be properly displayed.
1. Enter the Service mode. (See page 1-7-1.)
Press [9] button on the remote control unit and
select V-P mode. (Press [9] button then display will
change to V-P and V-S).
2. Input monoscope pattern.
3. Press [CH.
o
/
p
] buttons on the remote control
unit so that the top and bottom of the monoscope
pattern are equal to each other.
12. V. Size Adjustment
Purpose:
To obtain correct vertical height of screen
image.
Symptom of Misadjustment:
If V. Size is incorrect,
vertical height of image on the screen may not be
properly displayed.
1. Enter the Service mode. (See page 1-7-1.)
Press [9] button on the remote control unit and
select V-S mode. (Press [9] button then display will
change to V-P and V-S).
2. Input monoscope pattern.
3. Press [CH.
o
/
p
] buttons on the remote control
unit so that the monoscope pattern is 90
±
5% of
display size and the circle is round.
Test Point
Adj. Point
Mode
Input
---
Focus Control
---
Monoscope
Tape
M. EQ.
Spec.
---
Pattern Generator
See below
Test Point
Adj. Point
Mode
Input
---
[CH.
o
/
p
]
buttons
---
Monoscope
Tape
M. EQ.
Spec.
---
Pattern Generator
---
Test Point
Adj. Point
Mode
Input
---
[CH.
o
/
p
]
buttons
---
Monoscope
Tape
M. EQ.
Spec.
---
Pattern Generator
---
Test Point
Adj. Point
Mode
Input
---
[CH.
o
/
p
]
buttons
---
Monoscope
Tape
M. EQ.
Spec.
---
Pattern Generator
90
±
5%
Summary of Contents for MWC24T5
Page 41: ...1 11 3 Main 1 6 Sensor Schematic Diagram TV VCR Section T2202SCM1...
Page 42: ...1 11 4 T2202SCM2 Main 2 6 Schematic Diagram TV VCR Section...
Page 43: ...1 11 5 T2202SCM3 Main 3 6 Schematic Diagram TV VCR Section...
Page 44: ...1 11 6 Main 4 6 Schematic Diagram TV VCR Section T2202SCM4...
Page 45: ...1 11 7 T2202SCM5 Main 5 6 Junction A Schematic Diagram TV VCR Section...
Page 47: ...1 11 9 T2202SCSUB1 Sub 1 2 Schematic Diagram TV VCR Section...
Page 48: ...1 11 10 Sub 2 2 Schematic Diagram TV VCR Section T2202SCSUB2...
Page 50: ...1 11 12 T2202SCD1 DVD Main 1 3 Schematic Diagram DVD Section...
Page 51: ...1 11 13 T2202SCD2 DVD Main 2 3 Schematic Diagram DVD Section...
Page 52: ...1 11 14 T2202SCD3 DVD Main 3 3 Schematic Diagram DVD Section...
Page 72: ...1 17 2 T2203PEX Packing FRONT S4 S1 X1 Tape X4 X2 X3 S3 S6 S7 S2 Packing Tape...
Page 82: ...MWC24T5 T2202UC 2006 04 06...