1-7-2
T1200EA
2. Setting for CONTRAST, COLOR,
TINT, V-TINT and SHARP Data
Values
General
1. Enter the Service mode. (See page 1-7-1.)
2. Press [PICTURE] button on the service remote
control unit. Display changes “BRT,” “CNT,” “COL,”
“TNT,” “V-T,” and “SHP” cyclically when [PICTURE]
button is pressed.
CONTRAST (CNT)
1. Press [PICTURE] button on the service remote
control unit. Then select “CONTRAST (CNT)”
display.
2. Press [CH.
o
/
p
] buttons on the service remote
control unit so that the value of “CONTRAST
(CNT)” becomes 84.
COLOR (COL)
1. Press [PICTURE] button on the service remote
control unit. Then select “COLOR (COL)” display.
2. Press [CH.
o
/
p
] buttons on the service remote
control unit so that the value of “COLOR (COL)”
becomes 58.
TINT (TNT)
1. Press [PICTURE] button on the service remote
control unit. Then select “TINT (TNT)” display.
2. Press [CH.
o
/
p
] buttons on the service remote
control unit so that the value of “TINT (TNT)”
becomes 50.
V-TINT (V-T)
1. Press [PICTURE] button on the service remote
control unit. Then select “V-TINT (V-T)” display.
2. Press [CH.
o
/
p
] buttons on the service remote
control unit so that the value of “V-TINT (V-T)”
becomes 50.
SHARP (SHP)
1. Press [PICTURE] button on the service remote
control unit. Then select “SHARP (SHP)” display.
2. Press [CH.
o
/
p
] buttons on the service remote
control unit so that the value of “SHARP (SHP)”
becomes 46.
Note: BRIGHT
data value does not need to be
adjusted because this setting is performed in
other setting.
3. H f
0
Adjustment
Purpose:
To get correct horizontal position and size of
screen image.
Symptom of Misadjustment:
Horizontal position and
size of screen image may not be properly displayed.
Note:
R2583 --- Sub CBA
1. Connect frequency counter to R2583.
2. Operate the unit for at least 20 minutes.
3. Enter the Service mode. (See page 1-7-1.) Press
[2] button on the remote control unit and select H-
ADJ mode.
4. Press [CH.
o
/
p
] buttons on the remote control
unit so that the display will change “0” to “7.”
5. At this moment, choose display “0” to “7” when the
frequency counter display is closest to 15.734 kHz
±
300 Hz.
Test Point
Adj. Point
Mode
Input
R2583
[CH.
o
/
p
] buttons
Video
---
Tape
M. EQ.
Spec.
---
Frequency Counter 15.734 kHz
±
300 Hz
Summary of Contents for MWC20T6
Page 40: ...1 11 3 Main 1 5 Sensor Schematic Diagram TV VCR Section T1202SCM1 ...
Page 41: ...1 11 4 T1202SCM2 Main 2 5 Schematic Diagram TV VCR Section ...
Page 42: ...1 11 5 T1202SCM3 Main 3 5 Schematic Diagram TV VCR Section ...
Page 43: ...1 11 6 Main 4 5 Junction A Schematic Diagram TV VCR Section T1202SCM4 ...
Page 45: ...1 11 8 T1202SCSUB1 Sub 1 2 Schematic Diagram TV VCR Section ...
Page 46: ...1 11 9 Sub 2 2 Schematic Diagram TV VCR Section T1202SCSUB2 ...
Page 48: ...1 11 11 T1202SCD1 DVD Main 1 3 Schematic Diagram DVD Section ...
Page 49: ...1 11 12 T1202SCD2 DVD Main 2 3 Schematic Diagram DVD Section ...
Page 50: ...1 11 13 T1202SCD3 DVD Main 3 3 Schematic Diagram DVD Section ...
Page 70: ...1 17 2 T1200PEX Packing FRONT S4 S1 X1 Tape X4 X2 X3 S3 S6 S7 S2 Packing Tape ...
Page 79: ...MWC20T6 T1202UC 2006 03 17 ...