1-4-2
TD857EA
2. H Adjustment
Purpose:
To get correct horizontal position and size of
screen image.
Symptom of Misadjustment:
Horizontal position and
size of screen image may not be properly displayed.
Note:
R583 --- H.V. CBA
1. Connect frequency counter to R583.
2. Operate the unit for at least 20 minutes.
3. Enter the Service mode. (See page 1-4-1.) Press
"2" button on the service remote control unit and
select H-ADJ mode.
4. Press "CH
o
/
p
" buttons on the service remote
control unit so that the display will change "0" to
"7." At this moment, choose display "0" to "7" when
the frequency counter display is closest to
15.734kHz
±
300Hz.
5. Turn the power off and on again.
3. C-Trap Adjustment
Purpose:
To get minimum leakage of the color signal
carrier.
Symptom of Misadjustment:
If C-Trap Adjustment is
incorrect, stripes will appear on the screen.
Note:
D1304 (Cathode) (B-Out)--- Main CBA
1. Connect Oscilloscope to D1304 (Cathode).
2. Input a color bar signal from RF input.
Enter the Service mode. (See page 1-4-1.)
3. Press "0" button on the service remote control unit
and select C-TRAP Mode.
4. Press CH
o
/
p
buttons on the service remote
control unit so that the carrier leakage B-Out
(3.58MHz) value becomes minimum on the oscillo-
scope.
5. Turn the power off and on again.
4. V. Size Adjustment
Purpose:
To obtain correct vertical height of screen
image.
Symptom of Misadjustment:
If V. Size is incorrect,
vertical height of image on the screen may not be
properly displayed.
1. Enter the Service mode. (See page 1-4-1.)
Press "9" button on the service remote control unit
and select V-S mode. (Press "9" button then dis-
play will change to V-P and V-S).
2. Input monoscope pattern.
3. Press "CH
o
/
p
" buttons on the service remote
control unit so that the monoscope pattern is
90
±
5% of display size and the circle is round.
Test Point
Adj. Point
Mode
R583
CH
o
/
p
buttons
Video
M. EQ.
Spec.
Frequency Counter
15.734kHz
±
300Hz
Test Point
Adj. Point
Input
D1304
(Cathode)
(B-OUT)
CH
o
/
p
buttons
Color Bar
M. EQ.
Oscilloscope,
Pattern Generator
Figure
minimum
Fig. 2
Adj. Point
Input
CH
o
/
p
buttons
Monoscope
M. EQ.
Spec.
Pattern Generator
90
±
5%
Summary of Contents for 19MDTR17
Page 97: ...1 3 1 T0006IB OPERATING CONTROLS AND FUNCTIONS 27MDTR20 17 view...
Page 98: ...1 3 2 T0006IB 27MDTR20 17 view...
Page 99: ...1 4 1 T0006IBR REMOTE CONTROL OPERATION...
Page 100: ...1 4 2 T0006IBR...
Page 147: ...R583 H Adjustment Sub CBA Top View TV VCR Section 1 8 41 1 8 42 BT1000F01022 A...
Page 178: ...1 5 1 T1102IB OPERATING CONTROLS AND FUNCTIONS...
Page 179: ...1 5 2 T1102IB...
Page 180: ...1 5 3 T1102IB...
Page 181: ...1 5 4 T1102IB...
Page 277: ...2 4 9 N2466FTDA 43 41 42 L 13 Fig DM16 44 45 Slide P 9 Fig DM17...
Page 296: ...1 5 2 T1102IB...
Page 297: ...1 5 3 T1102IB...
Page 298: ...1 5 4 T1102IB...
Page 394: ...2 4 9 N2466FTDA 43 41 42 L 13 Fig DM16 44 45 Slide P 9 Fig DM17...