A-2045 Series

 

© 2015 Magnaflux 

Page 5 

Magnaflux-SRVC-IG002 

Issued: Apr 2015 

Rev. 2 

Optional Hood Enclosure 

with UV Light and Fan Assembly and White Light 

Note: Both the UV light and Fan Assembly plug into 
receptacles located on the unit. The Fan Assembly 
plugs into a 4 prong receptacle on the Headstock end 
of the unit and the ON/OFF switches for both the fan 
and white light are located on the Operator Control 
Panel. The UV light (supplied associated mounting 
bracket and transformer) will mount on the tailstock 
end of the unit and plug into the 115 outlet located 
there. 

Enclosure Foot Print: 

  

Open Dimensions 

Closed Dimensions 

Model 

Length 

Depth 

Height 

Length 

Depth 

Height 

Standard unit 

86″ 

(218 cm) 

50″ 

(127 cm) 

120″ 

(305 cm) 

86″ 

(218 cm) 

73″ 

(185 cm) 

89.5″ 

(227 cm) 

Long unit 
(AD-2045L) 

135″ 

(336 cm) 

50″ 

(127 cm) 

120″ 

(305 cm) 

135″ 

(336 cm) 

73″ 

(185 cm) 

89.5″ 

(227 cm) 

Extra long unit 
(AD-2045XL) 

178″ 

(452 cm) 

50″ 

(127 cm) 

120″ 

(305 cm) 

178″ 

(452 cm) 

73″ 

(185 cm) 

89.5″ 

(227 cm) 

Machine Only Footprint: 

Model 

Length 

Depth 

Height 

Standard unit 

84.5″ 

(215 cm) 

41″ 

(104 cm) 

60.25″ 

(153 cm) 

Long unit 
(AD-2045L) 

132.5″ 

(336 cm) 

41″ 

(104 cm) 

60.25″ 

(153 cm) 

Extra long unit 
(AD-2045XL) 

176.5″ 

(448 cm) 

41″ 

(104 cm) 

60.25″ 

(305 cm) 

Summary of Contents for AD-2045

Page 1: ...tulations on the purchase of your new Magnaflux AD 2045 Magnetic Particle Inspection Machine This guide will help you install and set up your new Magnaflux machine If you have any questions please contact your local Magnaflux Authorized Service Center or call Magnaflux Customer Service at 847 657 5300 ...

Page 2: ...onnect the incoming power to the Incoming Power Connection located inside the unit on the back side Attach the Chassis Ground wire to the inside of the unit to the Chassis Ground Connection Screw Follow all local electrical codes for wiring It is high ly recommended that an electrical fused disconnect be installed on the headstock side of the unit Either on the wall behind the unit or on a pedesta...

Page 3: ...ors for Resistance Welders NPFA National Electric Code 2011 Some areas refer to 2 phase instead of 1 phase The incoming power goes directly to an isolation transformer so the unit will operate identically on 1 or 2 phase power Electrical Input Input Volts AC Phase Full Load Amps Recommended Line Fuse Amps Recommended Wire Size AWG 208 1 350 250 2 0 230 1 300 250 1 380 1 175 125 3 415 1 160 125 4 4...

Page 4: ...ntamination is not introduced into the machine s inspection bath Contamination may include but not limited to grinding dust tool ing oil or coolant metal shavings wheelabrator sandblasting residue and paint chips Ways to prevent contamination include locating the machine in a dedicated room providing positive air pressure inside the Equipment Enclosure Hood Assembly keeping the front cur tain of t...

Page 5: ... transformer will mount on the tailstock end of the unit and plug into the 115 outlet located there Enclosure Foot Print Open Dimensions Closed Dimensions Model Length Depth Height Length Depth Height Standard unit 86 218 cm 50 127 cm 120 305 cm 86 218 cm 73 185 cm 89 5 227 cm Long unit AD 2045L 135 336 cm 50 127 cm 120 305 cm 135 336 cm 73 185 cm 89 5 227 cm Extra long unit AD 2045XL 178 452 cm 5...

Reviews: