BLUEPIRAT MINI | USER MANUAL /
page 43 of 62
Power consumption /
operating (typ.)
300 mA (@ 13.8 V)
300 mA (@ 13.8 V)
300 mA (@ 13.8 V)
300 mA (@ 13.8 V)
Power consumption /
operating (peak.)
5A
5A
5A
5A
Power consumption /
standby
< 1 mA
< 1 mA
< 1 mA
< 1 mA
Operating temperature
- 40 °C to + 70 °C
(+/-2°C)
- 40 °C to + 70 °C
(+/-2°C)
- 40 °C to + 70 °C
(+/-2°C)
- 40 °C to + 65 °C
(+/-2°C)
Storage temperature
- 40 °C to + 85 °C
- 40 °C to + 85 °C
- 40 °C to + 85 °C
- 40 °C to + 85 °C
Weight (ca.)
250 g
250 g
250 g
250 g
Power Management
bPMini 8 CAN
bPMini 4 CAN-FD
bPMini 8 LIN
bPMini 20 LIN
Startup time
from standby to full op-
eration
ca. 25 s
ca. 25 s
ca. 25 s
ca. 25 s
Start of logging -
starting from standby
CAN, LIN, Serial, Ana-
log, Digital
< 210 ms
CAN, LIN, Serial, Ana-
log, Digital
< 210 ms
CAN, LIN, Serial, Ana-
log, Digital
< 210 ms
CAN, LIN, Serial, Ana-
log, Digital
< 230 ms
Start of logging -
Ethernet / BroadR-
Reach, AutoNeg off
ca. 1,7s / 21s
ca. 1,7s / 21s
ca. 1,7s / 21s
ca. 1,7s / 21s
Standby Mode
Configurable time with-
out bus load
Configurable time with-
out bus load
Configurable time with-
out bus load
Configurable time with-
out bus load
Wake
HS-CAN, LS-CAN,
LIN, Serial, KL 15,
[ON / Trigger] button
HS-CAN, LS-CAN,
LIN, Serial, KL 15,
[ON / Trigger] button
HS-CAN, LS-CAN,
LIN, Serial, KL 15,
[ON / Trigger] button
HS-CAN, LS-CAN,
LIN, Serial, KL 15,
[ON / Trigger] button
Data loss by power loss
If the device is
switched off due to
sudden power loss, up
to 60 sec. of data may
be lost.
If the device is
switched off due to
sudden power loss, up
to 60 sec. of data may
be lost.
If the device is
switched off due to
sudden power loss, up
to 60 sec. of data may
be lost.
If the device is
switched off due to
sudden power loss, up
to 60 sec. of data may
be lost.
Case
bPMini 8 CAN
bPMini 4 CAN-FD
bPMini 8 LIN
bPMini 20 LIN
Size (ca.)
4,13" x 3,35" x 1,30"
(105 x 85 x 33 mm)
4,13" x 3,35" x 1,30"
(105 x 85 x 33 mm)
4,13" x 3,35" x 1,30"
(105 x 85 x 33 mm)
4,13" x 3,35" x 1,30"
(105 x 85 x 33 mm)
Operating controls
Push-button to start
and shut down data
logger and to set mark-
ers
Push-button to start
and shut down data
logger and to set mark-
ers
Push-button to start
and shut down data
logger and to set mark-
ers
Push-button to start
and shut down data
logger and to set mark-
ers
LEDs (STATE, ACTIVE)
Yes
Yes
Yes
Connectors
bPMini 8 CAN
bPMini 4 CAN-FD
bPMini 8 LIN
bPMini 20 LIN
Front connectors
2x Gbit Ethernet, SD
card, Micro--USB 2.0
2x Gbit Ethernet, SD
card, Micro--USB 2.0
2x Gbit Ethernet, SD
card, Micro--USB 2.0
2x Gbit Ethernet, SD
card, Micro--USB 2.0
Rear connectors
2x Gbit ETH
SUB-D 44-pol:
Power supply, 8x HS-
CAN, 1x LS-CAN, 2x
LIN, 5x Serial, 2x Ana-
log In, 2x Digital In, 2x
Digital Out, 2x BroadR-
Reach
2x Gbit ETH
SUB-D 44-pol:
Power supply, 4x
CAN-FD or HS-CAN,
1x LS-CAN, 2x LIN, 5x
Serial, 2x Analog In, 2x
Digital In, 2x Digital
Out, 2x BroadR-Reach
2x Gbit ETH
SUB-D 44-pol:
Power supply, 2x HS-
CAN, 1x LS-CAN, 8x
LIN, 5x Serial, 2x Ana-
log In, 2x Digital In, 2x
Digital Out
2x Gbit ETH
SUB-D 44-pol:
Power supply, 2x HS-
CAN, 1x LS-CAN, 8x
LIN, 5x Serial, 2x Ana-
log In, 2x Digital In, 2x
Digital Out
Data recording
bPMini 8 CAN
bPMini 4 CAN-FD
bPMini 8 LIN
bPMini 20 LIN
Storage type (internal)
58 GB flash
58 GB flash
58 GB flash
58 GB flash
Storage type (external)
USB flash drive
USB flash drive
USB flash drive
USB flash drive
SD card
SD card
SD card
SD card
Recording modes
Normal, ring buffer
Normal, ring buffer
Normal, ring buffer
Normal, ring buffer
Timestamp accuracy
1 µs
1 µs
1 µs
1 µs
CAN recording
bPMini 8 CAN
bPMini 4 CAN-FD
bPMini 8 LIN
bPMini 20 LIN
Channel
8 High Speed, 1 Low
Speed
4 CAN-Flexible Data or
High Speed, 1 Low
Speed
2 High Speed, 1 Low
Speed
1 High Speed, 1 Low
Speed
Baud rate
Up to 1000000 Baud at
HS-CAN
up to 125000 Baud at
LS-CAN
Up to 1000000 Baud at
HS-CAN and 5000000
at CAN-FD
up to 125000 Baud at
LS-CAN
Up to 1000000 Baud at
HS-CAN
up to 125000 Baud at
LS-CAN
Up to 1000000 Baud at
HS-CAN
up to 125000 Baud at
LS-CAN
Transceiver
TJA1041A, TJA1055T
TJA1041A, TJA1055T
TJA1041A, TJA1055T
TJA1041A, TJA1055T
Filter
CAN ID filter
CAN ID filter
CAN ID filter
CAN ID filter
Status recording
Error frames
Error frames
Error frames
Serial recording
bPMini 8 CAN
bPMini 4 CAN-FD
bPMini 8 LIN
bPMini 20 LIN
Type
RS232
RS232
RS232
RS232