Step

 1. 

C

heck 

y

our s

y

stem requirement at

 

 

 

 

Control Pan

el/S

ystem

/Ge

neral

 

for 

Window XP

 S

erv

i

ce Pack 2 or lat

er v

ersion

 

 

 

Exc

el Appli

cation/He

lp/A

bout 

Mi

crosoft E

xce

l

 

for 

Microsoft Excel 2

00

2 or l

at

e

r versi

on

 

 

 

Step

 

2

. I

nstal

l D

ata

Link softw

are.

 

 

Step

 3

. C

onn

ect Gate

Way 

and U

S

B cab

le t

y

o

ur com

puter

 

 

 

 

 

 

Step

 

4

. D

oub

le

 Cl

ick [Add 

Hard

ware]

 at [

Contr

ol 

Pan

e

l]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for ThermoBiscuit

Page 1: ...Quick Start Guide for ThermoBiscuit Wireless 8 Channel Thermocouple Monitor for Extreme Temperature Environments Copyright 2008 by Magna Systems L L C Revision 0 2 03 2009...

Page 2: ...Rev 0 2 2 This page intentionally left blank...

Page 3: ...e DataLink display but it will not be saved to your data file 7 To set up in Data Logging Mode follow DataLink Data Logger Instructions included below 8 Verify proper thermocouple operation by watchin...

Page 4: ...ntrol Panel System General for Window XP Service Pack 2 or later version Excel Application Help About Microsoft Excel for Microsoft Excel 2002 or later version Step 2 Install DataLink software Step 3...

Page 5: ...Rev 0 2 5 Step 5 A window Found New Hardware Wizard appears Select No not this time Step 6 Select Install the software automatically...

Page 6: ...Rev 0 2 6 Step 7 Window operating system shall locate USBXpress Device automatic ally Step 8 USB driver shall now be Installed successfully...

Page 7: ...r ThermoSleeve Step 1 Before positioning ThermoBiscuit inside an environment chamber installThermoSleeve onto ThermoBiscuit Step 2 Remove ThermoSleeve away from ThermoBiscuit after the set of hardware...

Page 8: ...he module to a measurement location such as an oven Remember to copy down the key code to access the module memory later Step 8 Exit DataLink Step 9 Once the test measurement is complete open DataLink...

Page 9: ...the time when the data retrieving mode is activated instead of the actual data collection time In order to reduce this time stamp discrepancy activate Start Collection as soon as the node is reconnect...

Page 10: ...the following procedure Step 8 Restart the DataLink and Select Repeat an Existing Test Step 9 Remove the batteries from the module S N 6051 and reinstall them on the module Step 10 Select the test con...

Page 11: ...stance value shall be greater than 1000 Ohms Otherwise it indicates that the power circuitry is damaged due to wrong battery installation Step 18 Send the module S N 6051 back to Magna Systems for an...