background image

2

 

©2020 MAGMATIC EFFECTS

 all rights reserved. Information, specifications, diagrams, images, and 

instructions herein are subject to change without notice. MAGMATIC EFFECTS logo and identifying 
product names and numbers herein are trademarks of MAGMATIC EFFECTS. Copyright protection 
claimed includes all forms and matters of copyrightable materials and information now allowed by 
statutory or judicial law or hereinafter granted.    Product names used in this document may be 
trademarks or registered trademarks of their respective companies and are hereby acknowledged.    All 
non-MAGMATIC brands and product names are trademarks or registered trademarks of their respective 
companies. 
 

MAGMATIC EFFECTS

 and all affiliated companies hereby disclaim any and all liabilities for property, 

equipment, building, and electrical damages, injuries to any persons, and direct or indirect economic 
loss associated with the use or reliance of any information contained within this document, and/or as a 
result of the improper, unsafe, insufficient and negligent assembly, installation, rigging, and operation of 
this product. 
 

MAGMATIC EFFECTS | 

6122 S. Eastern Ave. 

Los Angeles, CA. 90040 

323-582-3322 

|

 323-832-9142 fax

 |

 

www.elationlighting.com 

|

 [email protected]

 

Elation Professional B.V

Junostraat 2 

6468 EW Kerkrade, The Netherlands 

+31 45 546 85 66

 

|

 +31 45 546 85 96 fax

 

|

 

www.elationlighting.eu 

|

 [email protected] 

Elation Professional Mexico

 

AV Santa Ana 30 | Parque Industrial Lerma, Lerma, Mexico 52000 

+52 (728) 282-7070 

RISK GROUP 3 - RISK OF EXPOSURE TO ULTRAVIOLET (UV) 
RADIATION! 
FIXTURE EMITS HIGH INTENSITY WAVELENGTH OF 
ULTRAVIOLET LIGHT   
WEAR PROPER EYE AND SKIN PROTECTION. 
DO NOT OPERATE FIXTURE WITH DAMAGED/MISSING 
EXTERNAL COVER OR PROTECTIVE LENS. 
DO NOT LOOK DIRECTLY INTO THE (UV) LIGHT AND/OR VIEW 
(UV) LIGHT DIRECTLY WITH OPTICAL INSTRUMENTS THAT MAY 
CONCENTRATE THE LIGHT/RADIATION OUTPUT. 

AVOID PROLONGED PERIODS OF EXPOSURE. 
AVOID WEARING WHITE COLOR CLOTHING AND/OR USING (UV) PAINTS ON SKIN. 
AVOID DIRECT EYE AND/OR SKIN EXPOSURE AT DISTANCES SHORTER THAN 11 feet (3.3m). 
INDIVIDUALS SUFFERING FROM A RANGE OF EYE CONDITIONS, SUNLIGHT EXPOSURE 
DISORDERS, OR INDIVIDUALS USING PHOTOSENSITIVE MEDICATION, MAY EXPERIENCE 
DISCOMFORT IF EXPOSED TO THE ULTRAVIOLET (UV) LIGHT EMITTED FROM THIS FIXTURE. 

D O C U M E N T   V E R S I O N  

Due to additional product features and/or enhancements, an updated version of this 
document may be available online. Please scan the QR Code with your mobile device 
or visit 

www.elationlighting.com

 

for the latest revision/update of this manual, before 

installation and/or programming. 

Date 

Document 

Version 

Software 

Version 

 

DMX 

Channel Modes 

Notes 

07/08/2020 

1.0 

N/A 

N/A 

Initial release. 

 

Summary of Contents for Prisma Mini PAR 45

Page 1: ...Prisma Mini PAR 45 User Manual...

Page 2: ...rofessional B V Junostraat 2 6468 EW Kerkrade The Netherlands 31 45 546 85 66 31 45 546 85 96 fax www elationlighting eu info elationlighting eu Elation Professional Mexico AV Santa Ana 30 Parque Indu...

Page 3: ...S General Information 4 Limited Warranty USA Only 5 Warranty Returns USA Only 6 Safety Guidelines 7 Maintenance Guidelines 9 Fixture Overview 10 Installation Instructions 11 Specifications 14 Dimensio...

Page 4: ...t discard the shipping carton in the trash Please recycle whenever possible BOX CONTENTS Phoenix Connector x1 Positive Wire Tip Sheath x2 Negative Wire Tip Sheath x2 CUSTOMER SUPPORT Contact MAGMATIC...

Page 5: ...instructions guidelines and or user manual D This is not a service contract and this warranty does not include any maintenance cleaning or periodic check up During the periods as specified above Magm...

Page 6: ...ed freight pre paid and insured to MAGMATIC in Los Angeles CA or a MAGMATIC Authorized Service Center The RMA number must be clearly written on the outside of the return box and a brief description of...

Page 7: ...risk of damage and or personal injury PROTECTION CLASS 1 FIXTURE MUST BE PROPERLY GROUNDED THERE ARE NO USER SERVICEABLE PARTS INSIDE THIS UNIT DO NOT ATTEMPT ANY REPAIRS YOURSELF DOING SO WILL VOID Y...

Page 8: ...r cord by the plug end and NEVER pull out the plug by tugging the wire portion of the cord During the initial operation of this fixture a light smoke or smell may emit from the interior of the fixture...

Page 9: ...vice technician Should you need any spare parts please order genuine parts from your local MAGMATIC dealer Please refer to the following points during routine inspections A detailed electrical check b...

Page 10: ...10 F I X T U R E O V E R V I E W 1 Lens 2 Mounting Yoke Adjustment Nut 3 Mounting Yoke 4 Power Signal Cable Gland 5 Power Signal Cable 6 Safety Cable Attachment Point...

Page 11: ...uipment installer MUST be consulted to determine if the metal truss structure or surface is properly certified to safely hold the combined weight of the fixture s clamps cables and accessories Ambient...

Page 12: ...ate rating to the safety cable attachment point RIGGING Overhead rigging requires extensive experience including but not limited to calculating working load limits understanding the installation mater...

Page 13: ...tor into the desired signal output port on the driver making sure that the latch on the Phoenix connector engages with the signal output port Tighten the two screws located to each side of the wire te...

Page 14: ...col Support Master Slave Modes Onboard 4 Button Touch Control Panel CONNECTIONS 9 ft 2 74m 2 Conductor 14 Gauge IP Rated Power Data Pigtail Cable Attached CONSTRUCTION PHYSICAL PERFORMANCE Dimensions...

Page 15: ...15 D I M E N S I O N A L D R A W I N G S Drawings not to scale...

Page 16: ...SKU PSP145 EU 1237000235 UPC 810008261170...

Reviews: