background image

DMX SET

DMX ADDR

1 - 512

DMX MODE

1-CH
4-CH

7-CH

12-CH

PERSONALITY

MagApp Set

MagApp Name
MagApp Passcode
MagApp IP
MagApp Port

MagApp Reset

Complete
Failed, try 

again

MagApp > 

DMX & Magfly On / Off

Allows MagApp 

data to be con-

verted to DMX 

data and then 

sent out via DMX 

port and Magfly

LCD Set

Screen OFF

Never
10s
40s
1 min
2 min
5 min
10 min
20 min

Display Flip

0 deg
180 deg

Magfly Set

Magfly 

Channel

0 - 14

When Magfly is 

not equipped, 

selecting this 

function causes 

“Optional Module 

Not Installed” 

to show on the 

screen.

Magfly

ON / OFF

CONTINUED ON NEXT PAGE

13

Summary of Contents for JAVELIN

Page 1: ...User Manual JAVELIN US SKU RSJ150 UPC 810008261545...

Page 2: ...unsafe insufficient and negligent assembly installation rigging and opera tion of this product DOCUMENT VERSION Due to additional product features and or enhancements an updated version of this docume...

Page 3: ...Safety Guidelines 7 Overview 9 Installation 10 Operation 11 Control Panel 12 System Menu 13 DMX Channel Functions Values 17 LED Layout 18 Macros Table 19 Color List 20 Dimensional Drawings 21 Trouble...

Page 4: ...sh Please recycle whenever possible BOX CONTENTS Twist locking power cable CUSTOMER SUPPORT Contact MAGMATIC customer service for any product related service and support needs Also visit forums elatio...

Page 5: ...anual D This is not a service contract and this warranty does not include any maintenance cleaning or periodic check up During the periods as specified above Magmatic Effects will replace defective pa...

Page 6: ...pre paid and insured to MAGMATIC in Los Angeles CA or a MAGMATIC Authorized Service Center The RMA number must be clearly written on the outside of the return box and a brief description of the probl...

Page 7: ...TS INSIDE THIS UNIT DO NOT ATTEMPT ANY REPAIRS YOURSELF DOING SO WILL VOID YOUR MANUFACTURER S WARRANTY DAMAGES RESULTING FROM MODIFICATIONS TO THIS DEVICE AND OR THE DISREGARD OF SAFETY INSTRUCTIONS...

Page 8: ...from flames and flammable or explosive substances Never pour flammable liquids such as gas perfume etc into the fog machine Keep the device and fog fluid out of reach of children Use only under adult...

Page 9: ...Fog Outlet 2 LED Array 3 Wired Remote Port 4 DMX In 5 DMX Out 6 Power In 7 Breaker 8 Carry Handle 9 Touch Screen Display 10 Tank Fill Cap 11 Safety Cable Attachment 12 Tank Level Indicator OVERVIEW 9...

Page 10: ...SAFETY CABLE WHENEVER INSTALLING THIS UNIT IN A SUSPENDED ENVIRONMENT TO ENSURE THAT THE DEVICE WILL NOT FALL IF THE CLAMPS FAIL CLAMP INSTALLATION This device features attachment points for two 2 ome...

Page 11: ...ION While the fog duration setting can be set as high as 250 seconds the individual bursts of continuous fog output will only occur for a maximum of 8 seconds For example when the user sets a duration...

Page 12: ...the main menu will be displayed see Main Menu Screen below Press the main menu icon you would like to access Use the ENTER button to access sub menus and use the UP and DOWN buttons to make adjustment...

Page 13: ...On Off Allows MagApp data to be con verted to DMX data and then sent out via DMX port and Magfly LCD Set Screen OFF Never 10s 40s 1 min 2 min 5 min 10 min 20 min Display Flip 0 deg 180 deg Magfly Set...

Page 14: ...reen Last State Yes No When powered up device adheres to last settings from before power was shut off Default Yes No Restore to factory settings MANUAL LED Off Start or pause device operation accordin...

Page 15: ...Strobe LED Style LED Off Auto 1 4 Color 1 75 see Color Table MagRF1 Style LED Off Auto 1 4 Color 1 75 see Color Table MagRF2 Style LED Off Auto 1 4 Color 1 75 see Color Table MagRF3 Style LED Off Auto...

Page 16: ...he type of the device that the MagApp has connected to Phone Route router No MagApp IP IP address set by user MagFly Ch 0 14 Current MagFly channel DMX Addr 1 512 Current DMX address of unit DMX Mode...

Page 17: ...op 181 205 Fog burst lighting display loop 1s loop 206 230 Auto 2 231 255 Auto 1 2 2 000 255 Red1 0 to 100 4 3 000 255 Blue1 0 to 100 5 4 000 255 Amber1 0 to 100 5 000 255 Red2 0 to 100 3 6 000 255 Gr...

Page 18: ...LED LAYOUT for 12 Channel Mode ABBREVIATION LED ZONE NAME R1 Red 1 B1 Blue 1 A1 Amber 1 R2 Red 2 G2 Green 2 B2 Blue 2 A2 Amber 2 R3 Red 3 G3 Green 3 18...

Page 19: ...026 Macro 11 085 086 Macro 41 145 146 Macro 71 027 028 Macro 12 087 088 Macro 42 147 148 Macro 72 029 030 Macro 13 089 090 Macro 43 149 150 Macro 73 031 032 Macro 14 091 092 Macro 44 151 152 Macro 74...

Page 20: ...r 71 Color 10 Color 41 Color 72 Color 11 Color 42 Color 73 Color 12 Color 43 Color 74 Color 13 Color 44 Color 75 Color 14 Color 45 Color 15 Color 46 Color 16 Color 47 Color 17 Color 48 Color 18 Color...

Page 21: ...DIMENSIONAL DRAWINGS Dimensions may not be drawn to scale 21...

Page 22: ...nce CLEANING MAINTENANCE When storing your device be sure to store in a cool area Cover the device so that dust does not build up on the device When storing for long periods of time it is highly advis...

Page 23: ...luid Level Detection Compact Light Weight Mobile Design CONTROL 4 DMX Channel Modes 1 4 7 12 Onboard LCD Touch Control Panel DMX 512 and RDM Protocol Support Optional MagFly Wireless DMX Transceiver O...

Page 24: ...ordance with the included instructions may cause harmful interference to radio communications However there is no guarantee that inter ference will not occur in a particular installation If this devic...

Page 25: ...25...

Page 26: ......

Reviews: