EB3600-AB | Chapter 7 Rack Slide Installation
115
Chapter 7 Rack Slide Installation
Installing the EB3600 Chassis in a Rack
Installation of the EB3600 chassis in a rack-mount cabinet.
Rack Mounting
The PCIe expansion chassis can be installed in a rackmount cabinet that conforms to Electronic
Industries Alliance (EIA) standards for computer equipment. The cabinet must be tall enough to
accommodate the computer’s height and deep enough to accommodate the system’s depth, while
providing the proper clearances for air flow and cabling. A cabinet with a standard depth of 31.5 inches
(800mm) should be sufficient; however, a rack with a non-standard depth dimension of at least 28 inches
(660mm) will provide the suggested minimum front and rear chassis clearances needed for an installation.
The PCIe expansion chassis is designed to be supported in the cabinet with rack slides
Rack Slides
Two different rack slide kits are available, 26” and 28” Rack slide kits. Each rack slide kit comes with two
7.25” adjustable mounting bracket extensions for use with the rack slides.
Slide Rail Dimension Information