15. Safety Flap
To inspect the safety flap (part number 005025), remove the left wheel, when standing
behind the unit (see page 22). Pry the black cap off with a flat screw driver. Using an 8mm
Allen wrench, remove the bolt holding the safety flap in place.
Fig. 15a Fig. 15b
Apply anti-seize grease to the safety flap shaft before reassembly (see Fig. 15c). The
spring must be “loaded” prior to assembly. When spring is loaded, the safety flap spring will
rest directly on motor. To ensure spring is loaded, firmly hold safety flap against motor
housing by pressing on bottom left corner while tightening (see Fig. 15b). This will create
the gap required during assembly to prevent damage to the microswitch.
Fig. 15c Fig. 15d
Rests directly
on motor
X
Press on X during
reassembly