Magikist VS0 Instruction Manual Download Page 8

COIN BOX

(OR CONTROL BOX WITH PUSH BUTTONS)

RESET

LOAD

POWER

COIN

ACCEPTOR

COM

N.O.

HOT

COM

COIN

COUNTER

SUPPLY

HOT NEUTRAL

SETTINGS

COINS

TO START

SECONDS PER COIN

1 2 3 4

OPEN

OPEN

1 2 3 4 5 6 7 8

REMOTE

RESET

16

32

64

128

256

512

4

8

4

8

1

2

000125

YELLOW

BLUE

BLACK

INPUT

GRD

120VAC

COIN COUNTER

10AMP

INLINE FUSES

(120VAC MOTORS)

120V

VAC

MOTOR

GROUND STUD

120VAC 20AMP  SUPPLY

BLACK (LINE)

12 GA.

WHITE (NEUTRAL)

12 GA.

GREEN (GROUND)

GREEN

BLACK

WHITE

PUSH BUTTON

STOP/START

MAGIKIST CP900

ELECTRONIC

COIN ACCEPTOR

NC     NO      COM

MECHANICAL

COIN ACCEPTOR

WITH

MICROSWITCH

OR

OR

(NO)

START

(NO)

STOP

JUNCTION

BOX

MTV840 TIMER

RED

120V

VAC

MOTOR

120 Volt 2 Motor
VS0-CP coin operated model
VS0-CD coin operated model
VS0-PB pushbutton model

V1.1 20140513

ALTERATE WIRING

FACTORY WIRING

Summary of Contents for VS0

Page 1: ...e questions regarding your vacuum please contact your supplier who can provide you with the answers you require VS0 CP Model shown For future reference record the model and serial number located near the bottom of the vacuum body In addition if your vacuum has a lockable coin meter please record the key numbers for both the upper portion and the money drawer of the coin meter The key numbers are s...

Page 2: ...r or the top dome of the vacuum This equipment incorporates switches motors or similar parts that can produce arcs or sparks When installed in a service station or other gasoline dispensing locations install this appliance a minimum of 20 feet 6 meters horizontally from the exterior enclosure of any dispensing pump and a minimum of 18 inches 45 centimeters above ground level Use only as described ...

Page 3: ...ng later in this manual detailing the mounting hole locations 1 INSTALLATION 1 2 ELECTRICAL CONNECTIONS All local and national electric codes must be followed for installation and use Licensed electricians are recommended for installation Grounding Instructions This appliance must be connected to a grounded metal permanent wiring system or an equipment grounding conductor must be run with the circ...

Page 4: ... Coin Operated Models 2 1 1 Coin Meter Block Locks VS0 coin operated models are outfitted with a stainless steel coin meter The coin meter is divided into an upper section which houses the coin acceptor and timer and a lower section that is the money box where coins are collected once accepted The coin meter uses a unique BlockLock locking system that provides maximum security positive locking and...

Page 5: ... supplied to the timer The red LOAD light indicates that the vacuum is operating The reset button resets the timer and cancels any existing time Use a pen or similar object to press gently on the recessed reset button 2 2 VS0 Pushbutton Operated Models The non coin operated pushbutton model has 2 pushbuttons one start and the other stop mounted on the front of the control box Pressing the green st...

Page 6: ...ay not be sufficient to operate the electrical requirements of the vacuum and any other devices that may be operating on this same circuit Contact a certified electrician to check and ensure that breaker and wire size are sufficient for the vacuum and any other devices operating on the same circuit Vacuum motor fuse or fuses blown Motor brushes may be bad or shorted To confirm the problem is with ...

Page 7: ...Model Description Voltage Amperage Motors Fuses VS0 120 17 2 2 of 10A 3AB VS03 120 25 3 3 of 10A 3AB VS0H 240 8 2 2 of 8A 3AB VS03H 240 11 3 3 of 8A 3AB 5 0 SPECIFICATIONS ...

Page 8: ... COIN COUNTER 10AMP INLINE FUSES 120VAC MOTORS 120V VAC MOTOR GROUND STUD 120VAC 20AMP SUPPLY BLACK LINE 12 GA WHITE NEUTRAL 12 GA GREEN GROUND GREEN BLACK WHITE PUSH BUTTON STOP START MAGIKIST CP900 ELECTRONIC COIN ACCEPTOR NC NO COM MECHANICAL COIN ACCEPTOR WITH MICROSWITCH OR OR NO START NO STOP JUNCTION BOX MTV840 TIMER RED 120V VAC MOTOR 120 Volt 2 Motor VS0 CP coin operated model VS0 CD coin...

Page 9: ...ACK INPUT GRD 120VAC COIN COUNTER 10AMP INLINE FUSES 120VAC MOTORS 120VAC 30AMP SUPPLY BLACK LINE 10 GA WHITE NEUTRAL 10 GA GREEN GROUND GREEN BLACK WHITE PUSH BUTTON STOP START MAGIKIST CP900 ELECTRONIC COIN ACCEPTOR NC NO COM MECHANICAL COIN ACCEPTOR WITH MICROSWITCH OR OR NO START NO STOP JUNCTION BOX MTV840 TIMER GROUND STUD 120V VAC MOTOR RED BLUE 120V VAC MOTOR 120V VAC MOTOR 120 Volt 3 Moto...

Page 10: ...LLOW BLUE BLACK INPUT GRD 240VAC COIN COUNTER 8AMP INLINE FUSES 240VAC MOTORS 240V VAC MOTOR GROUND STUD 240VAC 15AMP SUPPLY BLACK L1 14 GA RED L2 14 GA GREEN GROUND GREEN BLACK Red PUSH BUTTON STOP START MAGIKIST CP900 ELECTRONIC COIN ACCEPTOR NC NO COM MECHANICAL COIN ACCEPTOR WITH MICROSWITCH OR OR NO START NO STOP JUNCTION BOX MTV841 TIMER BLUE 240V VAC MOTOR 240 Volt 2 Motor VS0H CP coin oper...

Page 11: ...ACK INPUT GRD 240VAC COIN COUNTER 8AMP INLINE FUSES 240VAC MOTORS 240VAC 20AMP SUPPLY BLACK L1 12 GA RED L2 12 GA GREEN GROUND GREEN BLACK RED PUSH BUTTON STOP START MAGIKIST CP900 ELECTRONIC COIN ACCEPTOR NC NO COM MECHANICAL COIN ACCEPTOR WITH MICROSWITCH OR OR NO START NO STOP JUNCTION BOX MTV841 TIMER GROUND STUD 240V VAC MOTOR BLUE WHITE 240V VAC MOTOR 240V VAC MOTOR 240 Volt 3 Motor VS03H CP...

Page 12: ...D 120V VAC MOTOR 120 Volt 2 Motor VS0 T toggle switch model 2 POLE TOGGLE SWITCH 20A 125VAC CONTROL BOX 8 AMP INLINE FUSES 240VAC MOTORS 240V VAC MOTOR GROUND STUD 240VAC 15AMP SUPPLY BLACK L1 14 GA RED L2 14 GA GREEN GROUND GREEN BLACK RED JUNCTION BOX BLUE 240V VAC MOTOR 240 Volt 2 Motor VS0H T toggle switch model 2 POLE TOGGLE SWITCH 10A 250AC V1 1 20140513 V1 1 20140513 ...

Page 13: ... 240V VAC MOTOR GROUND STUD 240VAC 15AMP SUPPLY BLACK L1 12 GA RED L2 12 GA GREEN GROUND GREEN BLACK RED JUNCTION BOX BLUE 240V VAC MOTOR 240 Volt 3 Motor VS03H T toggle switch model V1 2 20201002 V1 2 20201002 120V VAC MOTOR BLUE 240V VAC MOTOR WHITE CONTROL BOX 10AMP INLINE FUSES 120VAC MOTORS TOGGLE SWITCH 30A 125VAC CONTROL BOX 8 AMP INLINE FUSES 120VAC MOTORS TOGGLE SWITCH 15A 250VAC ...

Page 14: ...VS0 VS0H 26 26A 13R 13L 2 3 6A 9 29 31 32 14A 26 26A 8 32 6 19 30 14 22 36 25 24 23 36 25 24 23 1 11 12 17 20 17 20 21 4 5 5A 28 7 15 16 7 15A V1 1 20140513 ...

Page 15: ...B13R dust container 1 14 VB14 vac motor 120 volt vacuums 2 VB14 240 vac motor 240 volt vacuums 2 14A VB14A vac motor brush 120 volt vacuums 4 VB14A 240 vac motor brush 240 volt vacuums 4 15 ELCSW 220A SGL0 start push button 1 15A ELCSW15DS toggle switch 1 16 ELCSW 220A SRL0 stop push button 1 17 CBL106 block lock with 2 keys 2 19 VB19 stainless steel dome 1 20 CBL107 key for block lock 2 21 VB17 n...

Page 16: ...VS03 VS03H 26 26A 13R 13L 2 3 6A 8 9 29 36 19 31 32 32 14 14A 22 6 26 26A 30 1 11 12 17 20 17 20 21 28 4 5 5A 7 15 16 25 24 23 25 24 23 7 15A V1 1 20140513 ...

Page 17: ...VB13R dust container 1 14 VB14 vac motor 120 volt vacuums 3 VB14 240 vac motor 240 volt vacuums 3 14A VB14A vac motor brush 120 volt vacuums 6 VB14A 240 vac motor brush 240 volt vacuums 6 15 ELCSW 220A SGL0 start push button 1 15A ELCSW15DS toggle switch 1 16 ELCSW 220A SRL0 stop push button 1 17 CBL106 block lock with 2 keys 2 19 VB19 stainless steel dome 1 20 CBL107 key for block lock 2 21 VB17 ...

Page 18: ...TYP 7 2 1 5 75 75 D 0 50 A 4 5 CHANNEL WIRE ENTRANCE HOLE 1 00 DIA EDGED WITH SERRATED GROMMETTING DETAIL A MOUNTING TAB DETAIL BOTTOM VIEW 22 58 9 5 1 25 30 19 18 20 5 V1 1 20140513 VS0 Dimensions Mounting Pattern Junction Box Location ...

Page 19: ...hout limitation any warranties or merchantability or fitness for a particular purpose and all such warranties are hereby disclaimed and excluded by the manufacturer Repair or replacement of defective products as provided is the sole and exclusive remedy provided hereunder and the manufacturer shall not be liable for any further loss damages or expenses including incidental and consequential damage...