1) OVERVIEW

 

Thank  you

 

for  choosing  the  M

AGIK

M

INDER

  MM100  automatic  liquid  level  chemical  proportioner. The 

M

AGIK

M

INDER

  is  a  non-electric  device  that  automatically  maintains  the  level  and  concentration  of  a 

solution reservoir. To obtain the best performance from you M

AGIK

M

INDER

, please read the instructions 

thoroughly  before  proceeding.  In  addition,  please  observe  all  warnings  and  cautions  printed  on  the 
chemical’s label regarding proper use and handling.

2) PACKAGE CONTENTS 

Proportioner valve assembly with U-clamp and thumbscrews for mounting. 

Weighted float with ball chain.

Suction tube with foot valve and strainer.

Discharge tube.

Metering tip kit.

Instruction manual.

3) IMPORTANT INFORMATION

 

It is advisable to wear protective clothing (i.e. gloves) and eyewear when dispensing potentially 
hazardous  chemicals.  Also  ensure  that  reservoirs  used  for  proportioning  are  of  suitable 
construction  and/or  size.  Wear  protective  clothing  when  cleaning  and  maintaining  your 
equipment if hazardous chemicals are being used.

It is not

 

advisable to use the M

AGIK

M

INDER

 on other non-hazardous chemical applications after it 

was  used  with  hazardous  chemicals. This  is  especially  true  when  health  or  safety  might  be  a 
concern.  For  example,  do  not  use  your  M

AGIK

M

INDER

  for  dishwasher  soap  after  it  has  been 

used for insecticide. It would be advisable to have two separate proportioners for this purpose.

Attach the M

AGIK

M

INDER

 to standard tap water outlets only, with no more than 85 PSI maximum 

and no less than 25 PSI minimum.

4) PACKAGE CONTENTS

 

For the following instructions, it may be of assistance to refer to the exploded view on the last page of 
this manual.

1.

Select metering tip (refer to section 

Metering Tip Selection

) and insert tip (MM11) into metering 

tip fitting on eductor (MM10).

2.

Slide open end of suction tube (MM18a) over the metering tip fitting on eductor.

3.

Attach  end  of  discharge  tube  (MM17a)  with  clamp  and  flooding  ring  to  discharge  barb  on 
eductor.