background image

Page

 

2

 

of

 

16

 

INTRODUCTION

 

Thank

 

you

 

for

 

choosing

 

this

 

Magiglo

 

product.

 

All

 

of

 

our

 

products

 

carry

 

a

 

CE

 

mark

 

which

 

is

 

awarded

 

by

 

an

 

independent

 

test

 

house

 

(notified

 

body)

 

and

 

shows

 

the

 

fires

 

have

 

been

 

type

 

tested

 

to

 

meet

 

the

 

essential

 

requirements

 

of

 

the

 

European

 

Gas

 

Appliance

 

Directive

 

and

 

the

 

appropriate

 

British

 

Standards.

 

This

 

is

 

a

 

highly

 

efficient

 

Flueless

 

Inset

 

Live

 

Fuel

 

Effect

 

Appliance.

 

The

 

burner

 

system

 

is

 

very

 

clean

 

burning

 

and

 

a

 

catalyst

 

cleans

 

the

 

combustion

 

products

 

even

 

further.

 

A

 

thermostat

 

in

 

the

 

burner

 

control

 

system

 

adjusts

 

heat

 

output

 

to

 

maintain

 

a

 

room

 

temperature,

 

which

 

can

 

easily

 

be

 

set

 

by

 

the

 

user.

 

There

 

is

 

also

 

a

 

separate

 

control

 

to

 

adjust

 

the

 

flame

 

effect

 

as

 

required.

 

Please

 

demonstrate

 

its

 

operation

 

to

 

the

 

customer

 

before

 

leaving.

 

An

 

oxygen

 

depletion

 

sensing

 

pilot

 

light

 

is

 

also

 

fitted

 

and

 

will

 

sense

 

any

 

significant

 

oxygen

 

depletion

 

in

 

the

 

room

 

and

 

shut

 

the

 

fire

 

down

 

safely.

  

 

1.

 

APPLIANCE

 

DATA

 

Refer

 

to

 

the

 

appliance

 

data

 

(affixed

 

beside

 

control

 

knob)

  

ENSURE

 

THAT

 

THE

 

LOCAL

 

CONDITIONS

 

OF

 

USE

 

CORRESPOND

 

TO

 

THE

 

DATA

 

ON

 

THE

 

BADGE

 

 

 

 

Natural

 

Gas

 

G20

 

 

LPG

 

(Propane)

 

G31

 

Category

 

 

 

I2H

 

 

 

 

I3P

 

Supply

 

Pressure

 

 

 

20mBar

 

 

 

37mBar

 

Inlet

 

Pressure

  

 

 

20mBar

*

 

 

 

37mBar

*

 

  

Heat

 

Input

 

(net)

 

 

(High)

 

2.5kW

   

 

 

2.5kW

    

(180g/h)

 

 

 

(Low)

 

1.5kW

   

 

 

1.5kW

    

(107g/h)

 

Inlet

 

Connection

 

 

 

8mm

 

Compression

 

 

8mm

 

Compression

 

Injector

 

(manual

 

valve)

 

 

Elbow

 

92/300

   

 

Elbow

 

92/90

 

Injector

 

(remote)

 

 

 

Elbow

 

92/170

   

 

Elbow

 

92/85

 

 

*

The

 

inlet

 

pressure

 

must

 

be

 

within

 

+/

‐ 

1mBar

 

of

 

specification

 

with

 

all

 

gas

 

appliances

 

in

 

the

 

house

 

switched

 

on

 

and

 

also

 

with

 

just

 

the

 

Magiglo

 

heater

 

operating.

 

If

 

outside

 

of

 

this

 

tolerance

 

the

 

fault

 

is

 

most

 

likely

 

to

 

be

 

in

 

the

 

installation

 

pipe

 

work

 

or

 

service

 

governor

 

at

 

the

 

meter.

 

If

 

the

 

problem

 

is

 

the

 

meter

 

governor,

 

this

 

is

 

the

 

property

 

of

 

the

 

gas

 

service

 

provider

 

(such

 

as

 

Transco

 

/

 

National

 

Grid

 

0800

 

111999

 

or

 

Bord

 

Gais)

 

and

 

they

 

should

 

be

 

called

 

to

 

rectify

 

this.

 

The

 

fire

 

will

 

not

 

operate

 

correctly

 

if

 

the

 

pressures

 

are

 

incorrect.

 

 

2.

 

UNPACKING

 

THE

 

APPLIANCE

 

2.1

 

Carefully

 

examine

 

the

 

carton

 

for

 

damage

 

before

 

unpacking.

 

If

 

it

 

is

 

obviously

 

damaged,

 

consult

 

the

 

supplier

 

as

 

to

 

whether

 

to

 

proceed

 

with

 

the

 

installation.

 

2.2

 

Make

 

sure

 

the

 

carton

 

is

 

stood

 

upright

 

and

 

open

 

the

 

top.

 

Remove

 

the

 

cardboard

 

top

 

fitting

 

and

 

place

 

to

 

one

 

side;

 

this

 

box

 

can

 

be

 

used

 

as

 

a

 

hearth

 

protector

 

when

 

installing

 

the

 

fire.

 

2.3

 

Remove

 

the

 

fittings

 

boxes

 

contained

 

within

 

and

 

open

 

them

 

and

 

check

 

the

 

condition

 

of

 

the

 

contents.

 

Remove

 

the

 

fire

 

and

 

examine

 

its

 

general

 

condition,

 

paying

 

particular

 

attention

 

to

 

the

 

frame,

 

the

 

glass

 

front

 

and

 

fire

 

box

 

flanges.

 

2.4

 

If

 

satisfied

 

by

 

the

 

general

 

condition,

 

place

 

the

 

decorative

 

components

 

to

 

one

 

side

 

and

 

proceed

 

with

 

the

 

installation.

 

If

 

in

 

any

 

doubt,

 

seek

 

advice

 

from

 

the

 

supplier.

 

Read

 

these

 

instructions

 

fully

 

before

 

proceeding

 

even

 

if

 

you

 

have

 

fitted

 

this

 

model

 

before.

 

Summary of Contents for EMPATHY 16"

Page 1: ...iances Ltd Lands End Way Oakham Rutland LE15 6RB Telephone 44 0 1572 725570 Fax 44 0 1572 724390 e mail info magiglo co uk web www magiglo co uk MAG4240InstUser G20 31 Issue JUNE10 v1 TO OBTAIN YOUR F...

Page 2: ...n Injector manual valve Elbow 92 300 Elbow 92 90 Injector remote Elbow 92 170 Elbow 92 85 The inlet pressure must be within 1mBar of specification with all gas appliances in the house switched on and...

Page 3: ...o cubic metre m divide the room volume in cubic feet by 35 3 3 7 The heater must not be installed in high rise blocks of flats unless a gas supply already exists bed sitting rooms basements which are...

Page 4: ...rectly against a wall 4 3 The fire comes with a 60mm spacer fitted to the front trim we recommend that this spacer is left on as it will keep the surfaces of the fireplace cooler Any combustible mater...

Page 5: ...small hearth 50mm deep will be required to support the fire front No other hearth is required For all other applications use the hearth sizes in 4 8 4 14 Closure plate tape and foam seals are unsuita...

Page 6: ...e pushing gas pipes through walls seal the pipe ends to prevent debris entering the pipes 6 4 Drill and fit cable fixing positions in accordance with diagram or alternatively drill and fit screws thro...

Page 7: ...he burner It is important for clean burning that the correct moulding is fitted in the correct place There must be a clear gap between the two sets of coals pebbles Always replace the glass after layi...

Page 8: ...he pressure must still be within the tolerance of 1mb Now turn off all the other gas appliances and turn the fire down to pilot only the pressure must still be within the tolerance of 1mb If it is not...

Page 9: ...essive exposure to these materials may cause temporary irritation to the eyes skin and respiratory tract consequently it makes sense to take care when handling these parts to ensure that the release o...

Page 10: ...utlet Ratio of CO CO2 should be less than 0 002 within 30 minutes 20ppm CO per 1 CO2 A reading of CO in the room centre should give a rise of less than 9ppm over ambient peak reading The catalyst is u...

Page 11: ...urpose made battery housing Note If the fire emits a beeping sound this is just the safety system priming itself Because the remote control uses battery power when in the stand by mode The battery wil...

Page 12: ...r into a clearer position In the event of the fire not working check both of the above points before calling an engineer 5 To ignite the fire point the handset at the fire push and hold simultaneously...

Page 13: ...the test must be carried out in accordance with BS5871 Pt 4 The catalytic converter needs heat to work therefore before you start testing the fire must have been lit and burning on full for at least...

Page 14: ...e consult the relevant manufacturer Only use replacement catalyst supplied by Magiglo If you or the customer detects any odours from the fire please remember that the catalytic convertor is not an air...

Page 15: ...important to take a gas rate test over a reasonable period of time so that the capacity of the meter is used On low Input appliances such as our flueless this is even more critical because uncertaint...

Page 16: ...by a Gas Safe registered installer formerly CORGI within the first year as with all gas products every gas appliances must be serviced every year The appliance has not been subject to misuse accident...

Reviews: