Page 33
3.8. Installation Procedure
Before commencing installation, ensure that the intended installation will comply
with details in
General Information
on
Page 2
.
Carefully unpack the contents of the carton and check them against the checklist given on the
previous page.
Make sure that the fireplace opening is suitable for the installation of the fire and prepare the
fireplace to suit the dimensional requirements given in
SECTIONS
0
and
0
(i.e. fitting the fire
surround, the hearth, etc.).
1. For all models, place the burner centrally
within the fireplace opening and position
it as far back as possible.
2. For
Remote Control
and
Total Control
Models
fit the heat shield in a suitable
position.
3. No part of the burner tray should be
allowed to project beyond the vertical
plane of the fireplace opening.
4. Connect the gas supply to the inlet of the
gas valve via the isolating valve
supplied. Route the cable for the
Optimum Control if applicable
5. For LPG models, the gas bottle must be
fitted with a non-adjustable, low-pressure
regulator 37mbar (GB).
6. Remove the transit tape.
7. For Manual Control models. Proceed to
Section 0
. For other control options,
proceed to instructions from those in
Sections 0
to
0
as applicable.
3.8.1. Continuation of Installation - Remote Control Model
1. Unpack the box containing the Receiver
and the Hand Set.
2. Fit four AA (1.5V) batteries into the
receiver unit and the PP3 (9V) battery
into the transmitter (hand set).
3. Feed the cable from the receiver unit
heat shield to the spade terminals on the
control valve, keeping the cable clear of
the underside of the tray. The cable
connectors must be matched to the
appropriately sized spade connector.
4. Position the receiver under the heat
shield as shown in
Figure 30
.
5. Test the operation of the drive motor
using the hand set as per Users
Instructions (
Section 0 - 2.1.2 Lighting
Procedure (Remote
Control)
on page
7
).
6. Proceed
to
Section 0
to commission the
installation.
RECEIVER
UNIT
HEAT
SHIELD
Figure 30