P160 User Manual
15
8.
Communication Setting
Set communication parameters. Enter into ”Comm.”
1.
Ethernet: The device can communicate with
PC each other via the parameters you set.
2.
Serial Comm: The device can communicate
with PC each other via the serial port
parameters you set.
3.
PC Connection: Set the password and device
ID so that you can connect the device with
software in PC.
4.
Wireless Network
:
Turn on /off the WIFI
setting.
5.
ADMS: Settings used for connecting with
ADMS server
‘
6.
Wiegand Setup: The device can
communicate with other device via the
parameters you set.
Ethernet
Enter into “Comm.”
“Ethernet”
1.
IP Address: Modify it if necessary. It cannot be
same with PC.
2.
Subnet Mask: Modify it if necessary.
3.
Gateway: It is necessary to set an address if
the device and PC are in different network
segment. Modify it if necessary.
4.
DNS: Set the address of your DNS server.
5.
TCP COMM Port: Set the TCP communication
port.
6.
DHCP: Dynamic Host Configuration Protocol,
which is used to allocate dynamic IP addresses
to clients by a server.
7.
Display in Status Bar: Whether to display
network status icons in the status bar.