8
IMPORTANT:
Before you begin, unplug refrigerator or disconnect power. Remove food and any adjustable door or
utility bins from doors.
Door and Hinge Removal
1. Unplug refrigerator or disconnect power.
2. Keep both doors closed until you are ready to lift them free from the cabinet.
NOTE:
Provide additional support for the doors while the hinges are being moved. Do not
depend on the door magnets to hold the doors in place while you are working.
3. Remove the parts for the top hinge as shown in Top Hinge graphic. Lift the freezer door from
the cabinet.
4. Remove the parts for the center hinge as shown in the Center Hinge graphic. Lift the
refrigerator door free from the cabinet.
5. Remove the parts for the bottom hinge as shown in the Bottom Hinge graphic.
Door Reversal
Cabinet
1.
Remove the cover of upper hinge hole from left side and move them to opposite side (see
Graphic 1).
2.
Remove hole plugs from left side and move them to opposite side (see Graphic 2)
Doors
1. Remove door hinge hole plug from the top of freezer and refrigerator door (see graphic 4)
2. Remove the door stop from refrigerator door and move to the other side (see graphic 5)
3. Take out the left door stop of freezer door and screw from the accessory bag and fix it on the
handle (see graphic 3)
Note: The left door and the right door stop of the freezer door are different. They can’t replace
each other.
Door and Hinge Replacement
1.
Replace the parts for the bottom hinge as shown (see Bottom Hinge graphic). Tighten screws.
Replace the refrigerator door.
NOTE:
Provide additional support for the doors while the hinges are being moved. Do not
depend on the door magnets to hold the doors in place while you are working.
2.
Assemble the parts for the center hinge as shown and tighten all screws (see Center Hinge
graphic). Replace the freezer door.
3.
Assemble the parts for the top hinge as shown (see Top Hinge graphic). Do not tighten screws
completely.
4.
Line up the doors so that the bottom of the freezer door aligns evenly with the top of the
refrigerator door. Tighten all screws.
Final Steps
1. Check all holes to make sure that hole plugs and screws are in place.
2. Plug in refrigerator or reconnect power.
3. Reset the controls (see “ temperature control” section).
4. Return all removable door parts to doors and food to product.