Magic Chef KOT-131UB Installation Manual Download Page 5

5

A-2. Install the Mounting Plate

Step. 1 Setup position

a. Draw a line down the middle of the studs(See the Wall Construction, page 3)
b. Draw a vertical line on the wall at the center of the 30” wide space.

NOTE: Use the wall template for the rear wall.
Reference Wall Template prior to proceeding.
Installation of this product require TWO persons.

Step. 2 Drilling

Reference the Wall Template.

Step. 3 Install the damper

Fit the damper into the house duct. Be sure that the damper hinge is on the top and the damper swings free into the wall outlet.

Step. 4 Tightening the screws

Wall

House Duct

Damper

Foam Tape

Mounting Plate

To Attach the mounting plate to the wall using the toggle bolt assemblies and/or lag screws:

a. Insert toggle bolts through mounting plate at required locations and add the spring loaded toggles.

Be sure you leave space at least the thickness of the wall between the mounting plate and the end
of the toggle nut, (in closed position). If you do not leave this space, the toggle nut will not open
on the other side of the wall.

b. Position mounting plate on wall and insert toggle bolt assemblies through the drywall holes or

start the lag-screw(s) through the wall stud(s).

c. Next, secure mounting plate to the wall by tightening toggle bolt assemblies or lag screw(s).

d. Drill 3/16” diameter lag screw hole(s), into one or more wall studs.

(Remember, you must have at least one lag screw into a wall stud.)For stud
location refer to WALL CONSTRUCTION
see page 3

e. Tighten the lag screw(S) into wall stud(S)

Dry wall

Mounting plate

Take the 28" foam tapes and remove the paper from sticky side. Press the sticky side onto the front edge of the damper. (Don't stretch
the foam tape)

Spacing more than
Wall thickness

Summary of Contents for KOT-131UB

Page 1: ...Electric Code or the prevailing local code for this kilowatt rating The power supply cord and plug should be brought to a separate 20ampere branch circuit single grounded receptacle The outlet box sh...

Page 2: ...lips screwdrivers Electric Drill Motor 1 2 5 8 Wood Bits 3 16 Drill Bit Saw to cut exhaust opening if needed or Jig Saw Tin Snips if needed Pencil Tape Measure Paper Tape Duct Tape 3 2 5 6 0 8 4 7 1 I...

Page 3: ...gned to mate with a standard 3 1 4 x 10 rectangular duct If round duct is required a rectangular to round transition adapter must be used Do not use less than a 6 diameter duct REAR EXHAUST If rear or...

Page 4: ...cover and save screw Remove cover Step 2 Remove the screw 2 for Blower attachment and save screw Lift blower unit out of mounting location CAUTION Do not pull or stretch blower wiring Step 3 Roll the...

Page 5: ...at required locations and add the spring loaded toggles Be sure you leave space at least the thickness of the wall between the mounting plate and the end of the toggle nut in closed position If you d...

Page 6: ...cabinet Drill the holes following the instructions on the template Step 1 Protect the top of your range by placing a portion of the carton or some other heavy material over the cooking surface before...

Page 7: ...cabinet bottom For front to back or side to side adjustment slide the damper as needed With the damper out twist the damper to fit under the flaps of the blower plate Replace the damper and make sure...

Page 8: ...Horizontal ventilation only C 3 Mounting Microwave oven See the page 6 A 3 Mounting the Microwave oven You need not use damper for recirculation C 4 Install the Charcoal filter Remove the screws on th...