background image

MAGENTA MULTIVIEW™ SERIES 

3. Setup and Installation 

 

3.1 Data Mode Configuration 

AK1200 232  serial receivers are  configured in full modem bidirectional serial modes. If 
you are using the daisy chain option  or a multi-output  transmitter (T4,T5) a 
MultiView™ CAT5 matrix switch or MultiView™ CAT5 distribution amp, this mode must 
be changed to uni-directional broadcast . To do this, configure the internal Serial Digital 
Board (SDB)  to change the transmitters & receivers serial mode operation (See 

Appendix C

). This configuration should be done before making any cable connections 

and applying power. 
Alternatively, remove the internal daughterboard and use the AK1200 receivers built in 
simplex serial option with the appropriate jumper changes. 

 

SA series offer RS232 serial in addition to stereo audio. The serial signal is 3 wire TX, 
RX, GND and does not support full modem signals. Baud rates for the SA series are 
fixed at 9600. Simplex modes are supported without jumper or other changes by simply 
using the TX signal only. SA units require no configuration. 

 

SAP series offer pollable RS232 serial in addition to stereo audio. The serial signal is 3 
wire TX, RX, GND and does not support full modem signals. Baud rates for the SAP 
series are fixed at 9600. Simplex modes are supported without jumper or other changes 
by simply using the TX signal only. See Appendix G on configuration and use of SAP 
Series. 

 

3.2 Cabling Considerations 

 

• We recommend mounting and connecting all cabling to the Magenta MultiView Series 
components before applying power. 
• Makes sure that the CAT5 cable you intend to use has been tested to comply 
with the TIA/EIA 568B wiring specification (See 

Appendix A

). 

 

3.3 Making the Connections 

 

3.3.1 CONNECTIONS AND SETUP IN GENERAL 

 

This section contains figures showing connections with the specific Magenta MultiView 
Series models. In general, however, the connection and setup procedure at both 
transmitter and receiver ends is as follows: 

 
NOTE: all units must be the same  type for all supported features to function correctly. 
For example, a UTX set for R/L summed audio must be connected to an AK1200 set for 
R/L summed audio. Similarly, a UTX SA cannot be used with an AK1200. Video modes 
may function normally, but 4th pair options will not.

 

 
At the transmitter end (refer to the transmitter user guide) : 
 

1. Connect the source video to the Magenta MultiView Series transmitter video input 
port, which is an HD15 connector labeled SOURCE IN or VIDEO IN. 
 
2. If desired, attach a local monitor via the local monitor port to LOCAL OUT 
 
3. Make your audio or serial connections via the phoenix connector or DB9 connector 
as appropriate. 

Summary of Contents for MultiView AK1200

Page 1: ...1 MultiView AK1200 Receiver Quick Reference Setup Guide Magenta Research 128 Litchfield Road New Milford CT 06776 USA 860 210 0546 FAX 860 210 1758 www magenta research com...

Page 2: ...ty of their respective owners FEDERAL COMMUNICATIONS COMMISSION AND INDUSTRY CANADA RADIO FREQUENCY INTERFERENCE STATEMENTS This equipment generates uses and can radiate radio frequency energy and if...

Page 3: ...on the Single Port VGA Audio 5 3 3 3 Connections on the Single Port RS232 version 6 3 3 4 Connections on the Single Port SA SAP version 7 3 4 Video Adjustment 8 3 4 1 Cable Distance Compensation Setti...

Page 4: ...mpedance Video IN 75 ohms Audio models Audio IN if any 600 ohms minimum SPDIF audio models 75 Ohm Audio Characteristics Right Left summed A option SA SAP Full Stereo Line Level 600 Ohm Unbalanced Seri...

Page 5: ...ot intended for nor does it support distribution through an Ethernet network Do not connect these devices to any sort of networking or telecommunications equipment 2 2 Equipment You May Also Need Audi...

Page 6: ...SAP series are fixed at 9600 Simplex modes are supported without jumper or other changes by simply using the TX signal only See Appendix G on configuration and use of SAP Series 3 2 Cabling Considerat...

Page 7: ...deo should appear on the display make sure display is powered ON 4 To adjust video levels and skew compensation see Section 3 4 5 Please mount the AK1200 in a location that ensures the ventilation hol...

Page 8: ...without serial communications Figure 3 3 shows the Single Port MultiView CAT5 Video System with RS 232 Transmitter connections and Figure 3 4 shows the receiver connections NOTE Even though both tran...

Page 9: ...modes are not affected by this Serial signals are 3 wire RS232 Tx Rx ground and fixed at 9600 baud Full 9 pin modem signals are not supported Note when using the Magenta MultiView SA SAP series with...

Page 10: ...he proper EQ setting resulting in picture loss To Reset EQ and Skew values to 0 remove power from AK1200 Push and hold EQ Skew Knob in and re apply power 1 Push EQ Skew knob in once so that the R G B...

Page 11: ...module is not installed call for technical assistance An image file is available to assist in these settings see Section 3 4 1 for details See Figure 3 8 for an example 1 To adjust individual colors...

Page 12: ...set correctly turn knob slowly Check all cable connections The video signal s refresh rate may be set too high Reset to a lower refresh rate in your monitor configuration menu There may be a delay sk...

Page 13: ...r shift in the video This is a result of the clamping on the red and blue channels of the video serial el ive component RGB H V AC coupled video the View CAT5 XRTx Universal transmitter has been desig...

Page 14: ...nel 2 for Right audio and channel 1 for Left audio Pin RGBHV VGA RGBS RGsB Composite SVHS Y C YUV 1 Red Red Red C V 2 Green Green Green C Y Y 3 Blue Blue Blue U 4 5 Gnd Gnd Gnd 6 Red Red Red C V 7 Gre...

Page 15: ...inouts Appendix A Cabling Pinouts Table A 3 DB9 Male Serial connector Table A 4 T568B CAT5 pinout DB9 for RS232 Pin Full Duplex 3 wire SA SAP Simplex 1 DCD 2 RX RX 3 TX TX TX 4 DTR 5 Ground Ground Gro...

Page 16: ...lowing jumper location diagram as well as Table B 1 for jumper settings Figure B 1 AK1200 Jumper locations AUTO SYNC MODES JP8 controls sync clamping circuitry and works with the external switch label...

Page 17: ...o OFF 2 3 2 3 2 3 2 3 OFF OFF OFF OFF OFF OFF OFF Composite S Video Component Video see note below on daisy chaining With Left Right Line Level Audio 1 2 1 2 1 2 1 2 OFF ON ON OFF OFF OFF OFF With SDP...

Page 18: ...ure the unit is powered OFF 2 If necessary unplug all cables to the unit 3 Unscrew the top screw as well as the two set screws in the DB9 connector Lift the cover off Table C 1 shows the Transmitter S...

Page 19: ...using Mode 5 Mode Type Baud Max JP1 JP2 1 Simplex one way to 1500 ft 115k 1 2 See Notes 3 4 See Notes 5 6 IN 7 8 OUT 9 10 OUT 1 2 IN 3 4 OUT 5 6 OUT 7 8 OUT 9 10 IN 2 Full Duplex 2 way Short 500 ft 19...

Page 20: ...ble to change at the video source 1080P signals may also require this mode if the sync is a very narrow pulse The following details jumper settings to change the sync polarity of the horizontal and ve...

Page 21: ...pins 1 2 4 5 7 8 4 Insert the Skew assembly onto the PCB using 11 pin headers J16 and J17 5 The correct orientation of the skew board is to place the side with the Magenta logo into header J17 6 Reas...

Page 22: ...unit on a wall Figure F 2 shows the 4 Unit Rackmount Bracket which holds four units in a 19 x 1U rack Not shown are brackets for 6 units and brackets for AK and XR series receivers T4 transmitters The...

Page 23: ...is also recommended to keep a list of receiver addresses and locations to make it easier to determine which receiver display is desired to communicate with 1 Remove the top cover assembly of the rece...

Page 24: ...24 MAGENTA MULTIVIEW SERIES 22 Appendix G Pollable Serial Mode Address Chart...

Page 25: ...25 23 Appendix G Pollable Serial Mode Address Chart cont APPENDIX F Pollable Serial Mode...

Page 26: ...26 MAGENTA MULTIVIEW SERIES 24 NOTES...

Page 27: ...27 25 NOTES...

Page 28: ...28 MAGENTA MULTIVIEW SERIES Magenta Research 128 Litchfield Road New Milford CT 06776 USA 860 210 0546 FAX 860 210 1758 www magenta research com PN 5310201 01 Rev 03 Mar 2009...

Reviews: