background image

 

MAGENTA 4 PLAY SERIES 

Contents 

Chapter                                                                                                             Page 
 

1.

Specifications...................................................................................................2 

 
2.    Introduction ........................................….........................................................3 
      2.1 Overview................................................................................….................3 
      2.2 Equipment You May Also Need..........................................................…....3 
      2.3 Compatible Cabling ........................................................................…...….3 
 
3.    Setup and Installation.......................................… ......................................….4 
    3.1 Cabling Considerations.................................................................................4 
    3.2  Making the Connections.....................................................................…......5 
           3.2.1 Connections and Setup in General .......................................……......5 
           3.2.2 Connections on the Transmitter and Receiver…..............………..…..5 
 
4.    Troubleshooting..............................................................................................6 
    4.1 Common Problems .....................................................................................6 
     
Appendix A. Cabling Pinouts.........................................….....................................6 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

© 2007 by Magenta Research  All rights reserved. 

Magenta Research  
128 Litchfield Rd  
New Milford, CT.  06776 USA 

This document and the Magenta Research  products to which it relates, and the copyright in each, is the 
property of Magenta Research. Neither the document nor the products may be reproduced by any 
means, in whole or in part, without the prior written permission of Magenta Research.  Magenta Research 
makes no warranty or representation, either express or implied, with respect to this software or 
documentation, including their quality, performance, merchantability, or fitness for a particular purpose.  
As a result, this software or documentation are licensed "as is" and you, the licensee, are assuming the 
entire risk as to their quality and performance. 

In no event will Magenta Research be liable for direct, indirect, special, incidental, or consequential 
damages arising out of the use of or inability to use the software or documentation. 

 

Magenta Research and the Magenta Research logo are trademarks of Magenta Research. 
All other brands, product names, and trademarks are the property of their respective owners

 

 

1. Specifications 

 

Cable Required:         

Category 5, 5e, 6 

screened

 twisted pair (ScTP) 

Video Support:           

DVI Video modes 

Maximum  
Resolution and 
Refresh Rate:             

1080P, 1600x1200 (UXGA) 

Bandwidth:                 

4.95 Gbps

 

Connectors: 

               (2) DVI-D, (4) RJ-45, (1) DC power inlet 

Temperature 
Tolerance:                  

Operating: 32 to 104°F (0 to 40°C); 

                                     Storage: -4 to +140°F (-20 to +60°C) 

Humidity 
Tolerance:                  

Up to 80% noncondensing 

Enclosure:                  

Metal 

Power:                         

+5 VDC @ 1.25 A  max, Consumption: 6.25 watts maximum 

Size: 

                             1.25 "H x 4.25"W x 4.25"D (3.2  x 10.8 x  10.8 cm)  

Weight:                        

0.81 lb. (0.37 kg) - each 

Recommended  
maximum cable lengths: 

                                                         Screened UTP (ScTP) 
                   UXGA, 1080P                     150 ft 
                   720P, 1080I                        300 ft 

 

2. Introduction 

2.1 Overview 

 

The Magenta 4Play DVI video extenders extend 4 DVI signals over Category 5/5e/6 cable. 
Screened Cat5/5e/6 (ScTP) should be used for best video quality and to minimize EMI interference 
from external sources as well as interference from electrical noise on ground. Unshielded twisted 
pair may produce undesirable results. 

Each display device requires a Magenta Cats’ I receiver 

unit (sold separately) .

 

 

WARNING 

This equipment is not intended for, nor does it support, distribution 

through an Ethernet network. Do not connect these devices to any sort 

of networking or telecommunications equipment! 

 

2.2 Equipment You May Also Need 

 

• DVI M-M cables 
• HDMI to DVI cable adapter 
• Screened CAT5 cable (ScTP) 

 

2.3 Compatible Cabling 

 

Magenta Research products are compatible with screened (ScTP) Cat5/5e/6 data cabling.  

 

Note: The shielding on the cable MUST be connected at both ends using compatible 
screened RJ45 plugs. Failure to connect the cable shield at either end may affect video 
performance and allow signal interference. Contact cable manufacturer for appropriate 
connectors and instructions. 

 

CAT5/5e/6 cabling for the Magenta 4Play Series  must be pinned to the TIA-EIA T568B wiring 
specification (see appendix A)  We also highly recommend that all CAT5/5e/6 cables be pre-
terminated and tested. Cables terminated on-site or in an existing infrastructure should be tested 
before use to ensure compliance with the TIA-EIA T568B specification. Using incorrectly 
terminated CAT5/5e/6 cables can damage the Magenta 4Play Series. 
 
At the time of printing this manual, Magenta Research recommends Belden 1533 ScTP cable with 
Tyco (AMP) 5-569550 RJ-45 connectors. Please follow cable termination guidelines to ensure the 
shield is correctly connected on both ends of the cable. 

Specifications  