Version 1.6
32 | Daylight Savings Time Feature
MG6250 • Section Programming Guide
System Timers
Daylight Savings Time Feature
Country Codes
Table 9 lists countries and their respective codes. This information is required when programming section
[2045]
for the Daylight Savings Time feature. To enable
this feature, refer to section
[2002]
, option 5, on page 30.
Section
Description
Data (value from 000 to 255)
Default Setting
[2020]
Entry delay 1
____/____/____ seconds
045 sec.
[2021]
Entry delay 2
____/____/____ seconds
045 sec.
[2022]
Intellizone delay
____/____/____ seconds (minimum 10 seconds)
045 sec.
[2023]
Recent closing delay
____/____/____ seconds
Disabled
[2024]
Auto-zone shutdown counter
____/____/____ times
005 times
[2025]
Remote lock delay
____/____/____ seconds
020 sec.
[2026]
Delinquency delay
____/____/____ days
Disabled
[2027]
Power failure report delay
____/____/____ minutes
015 min.
[2028]
Pre-alarm delay (StayD)
____/____/____ seconds
015 sec.
[2029]
Re-arm delay (StayD)
____/____/____ seconds
005 sec.
[2030]
Entry delay audio selection
____/____/____ (000 to 006
*
)
005
[2031]
Exit delay audio selection
____/____/____ (000 to 006
*
)
002
[2032]
Number of rings
____/____/____ rings
008 rings
[2033]
Answering machine override delay
____/____/____ seconds
030 sec.
[2034]
TLM fail timer
____/____/____ seconds
032 sec.
[2035]
Delay alarm transmission
____/____/____ seconds
Disabled
[2036]
Delay between dialling attempts
____/____/____ seconds (maximum 130 seconds)
020 sec.
[2037]
Lowest rate (primary communication)
____/____ (
01=landline
; 02 = GSM)
Disabled
[2038]
Auto-test report
____/____/____ days
Disabled
[2039]
Auto-test report time
____/____:____/____
Disabled
[2040]
GSM network failure delay
____/____/____ seconds
032 sec.
[2041]
GPRS bandwidth saver delay
____/____/____ minutes
Disabled
[2042]
EN50131 fail to communicate timer
____/____/____ seconds
0
[2043]
Keypad lockout
____/____/____ attempts
0 attempts
[2044]
Keypad lockout duration
____/____/____ minutes
Report only
[2048]
Trouble shutdown
____/____/____ times
0
[2049]
Panic shutdown
____/____/____ times
0
* 000 = No tone; 001 = Beeping; 002 = Countdown; 003 = Tonality 1; 004 = Tonality 2; 005 = Tonality 3; 006 = Tonality 4
Table 9: Country codes for the MG6250
Input Value
Country
Input Value
Country
00
Mexico; St. Johns; Bahamas; Turks and Caicos
10
Chatham
01
Cuba
11
Tonga
02
Brazil
12
Iraq; Syria
03
Chile
13
Israel
04
Falkland Islands
14
Lebanon; Kyrgyzstan
05
Paraguay
15
Palestine
06
European Union; United Kingdom; Greenland
16
Egypt
07
Russia and surrounding countries
17
Namibia
08
South Australia; Victoria; Australian Capital Territory; New
South Wales
18
Canada; United States
09
Tasmania; Lord Howe Island
19
New Zealand
Section
Description
Data
[2045]
Country code
___/___
value from 00 to 99
Summary of Contents for MG6250
Page 45: ...MG6250 Section Programming Guide Version 1 6 Entering Information 45 Figure 4 Greek ...
Page 46: ...Version 1 6 46 Entering Information MG6250 Section Programming Guide Figure 5 Turkish ...
Page 47: ...MG6250 Section Programming Guide Version 1 6 Entering Information 47 Figure 6 Hebrew ...