Entering Programming Mode
Use the built-in keypad to access Magellan’s installer programming mode. To access programming mode:
1. Press and hold the
[0]
key.
2. Enter your
[
INSTALLER
CODE
]
or
[
MAINTENANCE
CODE
]
.
3. Enter the 3-digit
[
SECTION
]
you wish to program.
4. Enter the required
[
DATA
]
.
5. Press the
[*]
key to clear data or to go back one step. Press the
[#]
key to save changes.
There are two methods that can be used to enter data when in programming mode: Single Digit Data Entry and Feature Select
Programming methods.
Single Digit Data Entry Method
After entering programming mode, some sections will require that you enter decimal
values from 000
to
255. Other sections will
require that you enter hexadecimal values from 0 to F. The required data will be clearly indicated in this manual. When entering the
final digit in a section, Magellan will automatically save and advance to the next section. Refer to Figure 1 on page 2 to see the keys
and their equivalent decimal and/or hexadecimal value.
Feature Select Programming Method
After entering certain sections, eight options will be displayed where each option from
[1]
to
[8]
represents a specific feature. Press
the key corresponding to the desired option and the option number will appear in the LCD screen. This means the option is ON.
Press the key again to remove the digit from the LCD screen (a
*
appears), thereby, turning OFF the option. Press the
[*]
key to set
all eight options to OFF. When the options are set, press the
[#]
key to save and advance to the next section.
Installer Quick Keys
To access the Installer Quick keys, press and hold the
[0]
key from the Main keypad, enter the
[
INSTALLER
CODE
]
and then press from the
Center keypad:
Key
[1]
=
Test Report:
Send the “Test Report” report code programmed in section [155] (page 10) to the monitoring station.
Key
[2]
=
Cancel Communication:
Cancels all communication with the WinLoad software or with the monitoring station until the next reportable event.
Key
[3]
=
Answer WinLoad Software:
Will force the console to answer an incoming call from the monitoring station that is using the WinLoad software.
Key
[4]
=
Call WinLoad Software:
Will dial the PC telephone number programmed in section [118] (page 8) in order to initiate communication with a
computer using the WinLoad software.
Key
[5]
=
Installer Test Mode:
The installer test mode will allow you to perform walk tests where the siren will squawk to indicate opened zones. Press the
[5]
key again to exit.
Zone Programming
Section
Description
Zone Definition
Zone Options
Section
Description
Zone Definition
Zone Options
[001]
Zone 1:__________
____/____/____ 1 2 3 4 5 6 7 8
[009]
Zone 9:__________
____/____/____ 1 2 3 4 5 6 7 8
[002]
Zone 2:__________
____/____/____ 1 2 3 4 5 6 7 8
[010]
Zone 10:_________
____/____/____ 1 2 3 4 5 6 7 8
[003]
Zone 3:__________
____/____/____ 1 2 3 4 5 6 7 8
[011]
Zone 11_________
____/____/____ 1 2 3 4 5 6 7 8
[004]
Zone 4:__________
____/____/____ 1 2 3 4 5 6 7 8
[012]
Zone 12:_________
____/____/____ 1 2 3 4 5 6 7 8
[005]
Zone 5:__________
____/____/____ 1 2 3 4 5 6 7 8
[013]
Zone 13:_________
____/____/____ 1 2 3 4 5 6 7 8
[006]
Zone 6:__________
____/____/____ 1 2 3 4 5 6 7 8
[014]
Zone 14:_________
____/____/____ 1 2 3 4 5 6 7 8
[007]
Zone 7:__________
____/____/____ 1 2 3 4 5 6 7 8
[015]
Zone 15:_________
____/____/____ 1 2 3 4 5 6 7 8
[008]
Zone 8:__________
____/____/____ 1 2 3 4 5 6 7 8
[016]
Zone 16:_________
____/____/____ 1 2 3 4 5 6 7 8
Zone Definitions (
)
000
= Zone Disabled (default)
001
= Entry Delay 1
002
= Entry Delay 2
003
= Follow Zone
004
= Follow / Stay Zone
005
= Instant Zone
006
= Instant / Stay Zone
007
= Instant Fire Zone
008
= Delayed Fire Zone
009
= 24Hr. Burglary Zone
010
= 24Hr. Hold-up Zone
011
= 24Hr. Buzzer Zone
012
= 24Hr. Gas Zone
013
= 24Hr. Heat Zone
014
= 24Hr. Water Zone
015
= 24Hr. Freeze Zone
J
[4]
J
[6]
Zone Options
[1] = Auto-zone Shutdown (default)
[2] = Bypassable Zone (default)
[3]
= Future Use
[6]
= Intellizone
[7]
= Delay alarm transmission
[8] = Force Zone (default)
† Intellizone is not for use in UL
installations.
‡ Force Arming is not permitted in UL
installations.
[4]
[5]
Zone Alarm Type
OFF OFF Audible alarm (default)
OFF ON Pulsed
alarm
ON OFF Silent alarm
ON ON Report only