Entering Programming Mode

Use the built-in keypad to access Magellan’s installer programming mode. To access programming mode:

1. Press and hold the 

[0]

 key.

2. Enter your 

[

INSTALLER

 

CODE

]

 or 

[

MAINTENANCE

 

CODE

]

.

3. Enter the 3-digit 

[

SECTION

]

 you wish to program.

4. Enter the required 

[

DATA

]

.

5. Press the 

[*]

 key to clear data or to go back one step. Press the 

[#]

 key to save changes.

There are two methods that can be used to enter data when in programming mode: Single Digit Data Entry and Feature Select 
Programming methods.

Single Digit Data Entry Method

After entering programming mode, some sections will require that you enter decimal

 

values from 000

 

to

 

255. Other sections will 

require that you enter hexadecimal values from 0 to F. The required data will be clearly indicated in this manual. When entering the 
final digit in a section, Magellan will automatically save and advance to the next section. Refer to Figure 1 on page 2 to see the keys 
and their equivalent decimal and/or hexadecimal value.

Feature Select Programming Method

After entering certain sections, eight options will be displayed where each option from 

[1] 

to

 [8]

 represents a specific feature. Press 

the key corresponding to the desired option and the option number will appear in the LCD screen. This means the option is ON. 
Press the key again to remove the digit from the LCD screen (a 

*

 appears), thereby, turning OFF the option. Press the 

[*]

 key to set 

all eight options to OFF. When the options are set, press the 

[#]

 key to save and advance to the next section.

Installer Quick Keys

To access the Installer Quick keys, press and hold the 

[0]

 key from the Main keypad, enter the 

[

INSTALLER

 

CODE

]

 and then press from the 

Center keypad:

Key 

[1]

 =

Test Report:

 Send the “Test Report” report code programmed in section [155] (page 10) to the monitoring station. 

Key 

[2]

 =

Cancel Communication:

 Cancels all communication with the WinLoad software or with the monitoring station until the next reportable event.

Key 

[3]

 =

Answer WinLoad Software:

 Will force the console to answer an incoming call from the monitoring station that is using the WinLoad software. 

Key 

[4]

 =

Call WinLoad Software:

 Will dial the PC telephone number programmed in section [118] (page 8) in order to initiate communication with a 

computer using the WinLoad software.

Key 

[5]

 =

Installer Test Mode:

 The installer test mode will allow you to perform walk tests where the siren will squawk to indicate opened zones. Press the 

[5]

 key again to exit.

Zone Programming

Section

Description

Zone Definition

Zone Options

Section

Description

Zone Definition

Zone Options

[001]

Zone 1:__________

____/____/____ 1 2 3 4 5 6 7 8

[009]

Zone 9:__________

____/____/____ 1 2 3 4 5 6 7 8

[002]

Zone 2:__________

____/____/____ 1 2 3 4 5 6 7 8

[010]

Zone 10:_________

____/____/____ 1 2 3 4 5 6 7 8

[003]

Zone 3:__________

____/____/____ 1 2 3 4 5 6 7 8

[011]

Zone 11_________

____/____/____ 1 2 3 4 5 6 7 8

[004]

Zone 4:__________

____/____/____ 1 2 3 4 5 6 7 8

[012]

Zone 12:_________

____/____/____ 1 2 3 4 5 6 7 8

[005]

Zone 5:__________

____/____/____ 1 2 3 4 5 6 7 8

[013]

Zone 13:_________

____/____/____ 1 2 3 4 5 6 7 8

[006]

Zone 6:__________

____/____/____ 1 2 3 4 5 6 7 8

[014]

Zone 14:_________

____/____/____ 1 2 3 4 5 6 7 8

[007]

Zone 7:__________

____/____/____ 1 2 3 4 5 6 7 8

[015]

Zone 15:_________

____/____/____ 1 2 3 4 5 6 7 8

[008]

Zone 8:__________

____/____/____ 1 2 3 4 5 6 7 8

[016]

Zone 16:_________

____/____/____ 1 2 3 4 5 6 7 8

Zone Definitions (

)

000

 = Zone Disabled (default)

001

 = Entry Delay 1

002

 = Entry Delay 2

003

 = Follow Zone

004

 = Follow / Stay Zone

005

 = Instant Zone

006

 = Instant / Stay Zone

007

 = Instant Fire Zone

008

 = Delayed Fire Zone

009

 = 24Hr. Burglary Zone

010

 = 24Hr. Hold-up Zone

011

 = 24Hr. Buzzer Zone

012

 = 24Hr. Gas Zone

013

 = 24Hr. Heat Zone

014

 = 24Hr. Water Zone

015

 = 24Hr. Freeze Zone

J

[4] 

J

[6]

Zone Options

[1] = Auto-zone Shutdown (default)
[2] = Bypassable Zone (default)
[3]

 = Future Use

[6]

 = Intellizone

[7]

 = Delay alarm transmission

[8] = Force Zone (default)

† Intellizone is not for use in UL 
installations.
‡ Force Arming is not permitted in UL 
installations.

[4]

[5]

Zone Alarm Type

OFF OFF Audible alarm (default)

OFF ON Pulsed 

alarm

ON OFF Silent alarm
ON ON Report only

Summary of Contents for MG-6030

Page 1: ...Programmable Outputs PGMs 5 System Options 5 Communicator Settings 8 Report Codes 9 Remote Control Button Programming 10 System Settings 11 Wireless Programmable Output PGM Settings 12 Appendix 1 PGM...

Page 2: ...it can be any value from 0 to 9 See section 182 on page 11 to change the default code Master Code Default 1234 123456 With the System Master code a user can use any arming method and can program user...

Page 3: ...nLoad Software Will force the console to answer an incoming call from the monitoring station that is using the WinLoad software Key 4 Call WinLoad Software Will dial the PC telephone number programmed...

Page 4: ...ell cut off time 004 mins 064 ____ ____ ____ x 15 minutes No movement time Disabled 065 ____ ____ ____ seconds minimum 10 seconds Intellizone delay 045 secs 066 ____ ____ ____ seconds Recent closing d...

Page 5: ...Silent or audible alarm Silent Audible 6 Panic 3 Silent or audible alarm Silent Audible 7 PGM1 used as MG 6060 only Direct output X10 output 7 8 PGM2 used as MG 6060 only Direct output X10 output 8 09...

Page 6: ...n trouble if detected on bypassed zone No Yes 095 Zone Options Bold Default setting Option OFF ON 1 Zone 15 is hardwire zone 1 Disabled Enabled 2 Zone 16 is hardwire zone 2 Disabled Enabled 3 EOL End...

Page 7: ...se Alarm Alarm Restore Report Codes 5 Call monitoring station telephone number 1 Disabled Enabled 6 Call monitoring station telephone number 2 Disabled Enabled 7 Call Pager telephone number Disabled E...

Page 8: ...eport format for monitoring station telephone number 2 107 ____ ____ ____ ____ Account number 108 ____ ____ ____ ____ Panel identifier for use with WinLoad software 109 ____ ____ ____ ____ Panel passw...

Page 9: ...____ ____ User Code 12 123 ____ ____ User Code 13 129 ____ ____ User Code 13 ____ ____ User Code 14 ____ ____ User Code 14 ____ ____ User Code 15 ____ ____ User Code 15 ____ ____ User Code 16 ____ __...

Page 10: ...Zone 6 ____ ____ Fail to comm ____ ____ Future use ____ ____ Installer logout ____ ____ Zone 7 ____ ____ TX low battery ____ ____ TX low battery ____ ____ Delinquency ____ ____ Zone 8 ____ ____ TX su...

Page 11: ...165 5 ______ ______ ______ ______ 173 13 ______ ______ ______ ______ 166 6 ______ ______ ______ ______ 174 14 ______ ______ ______ ______ 167 7 ______ ______ ______ ______ 175 15 ______ ______ ______...

Page 12: ...ent programmed 216 PGM4 Activation Event ____ ____ ____ ____ No event programmed 217 PGM4 Deactivation Event ____ ____ ____ ____ No event programmed Section 218 Wireless PGM Supervision Options Bold D...

Page 13: ...e center keypad 14 Utility Key 2 pressed keys 2 and 10 from the center keypad 15 Utility Key 3 pressed keys 3 and 11 from the center keypad 16 Utility Key 4 pressed keys 4 and 12 from the center keypa...

Page 14: ...gency 01 Panic medical this medical panic alarm is not UL approved 02 Panic fire 03 Recent closing 04 Global shutdown 05 Duress alarm User 16 99 Any special alarm event 25 Zone shutdown 01 to 16 Zone...

Page 15: ...d 43 PGM supervision lost 44 PGM supervision restored 45 PGM tampered 46 PGM tamper restored 01 to 04 PGM number 99 Any PGM number 47 Future use Future use 48 Fire delay started 01 to 16 Zone number 9...

Page 16: ...res into the AC terminals Back view of the Magellan console 12Vdc to 18Vdc 1A Insert the transformer s wires into the AC terminals DC Power Supply Backview of the Magellan console Insert the backup ba...

Page 17: ...and ahead of all other equipment attached to the same telephone line Proper installation is depicted in the diagram below If you have any questions concerning these instructions you should consult you...

Page 18: ...the Radio Antenna MG 6060 only Figure 9 Connecting the Radio Antenna Back view of the Magellan console If the radio reception is not very good connect the supplied radio antenna to the ANT terminal of...

Page 19: ...RJ 11 cable into the X10 plug of the console 2 Connect the other end of the inverted 4 pin RJ 11 cable into the X10 transmitter 3 Plug the X10 transmitter into a standard wall outlet 1 2 3 Do not con...

Page 20: ...n will begin downloading the data from the memory key Copy Data to Memory Key from Source Console To copy the contents of a console into the memory key 1 Remove power from the Magellan console AC and...

Page 21: ...e used to raise the Magellan console to a slight angle for easy viewing while the rubber stops prevent the console from sliding when Magellan is being used Tabletop mounting may not be an approved ins...

Page 22: ...352 Telco 2 fault 5F 125 Duress Egress granted 12 System Troubles 300 and 310 353 Long range radio 60 Burglar Alarms 130 300 System trouble 39 354 Fail to communicate 61 130 Burglary 13 301 AC loss 3A...

Page 23: ...521 Bell 1 disabled AA 626 Time Date inaccurate D1 412 Success download access 84 522 Bell 2 disabled AB 627 Program mode entry D2 413 Unsuccessful access 85 523 Alarm relay disabled AC 628 Program mo...

Page 24: ...Open by user OR Disarm from Alarm Cancel alarm with User Code 1 4A6 Open by user OR Disarm from Alarm Cancel alarm with Keyswitch 1 4A6 Keyswitch Open OS Opening Keyswitch Auto Arming Cancellation 1 4...

Page 25: ...attery Trouble Module Auxiliary supply trouble 1 3AA System trouble YP Power Supply Trouble Bus fault restore 3 333 Expansion module failure restore ER Expansion Restoral Module tamper restore 3 145 E...

Page 26: ...e product Seller s warranty as hereinabove set forth shall not be enlarged diminished or affected by and no obligation or liability shall arise from Seller offering to render or rendering technical ad...

Page 27: ......

Page 28: ...ring volume ring tone 9 demo mode on time on zone open remote button on exit delay when armed on entry delay on alarm house code Must enter the installer maintenance or user code to access Master Cod...

Reviews: