The boiler is not covered by the warranty if:
• is not operated with the prescribed
fuel,
• the Laddomat 21
-60, 21-100 or MAGAMAT 60 ° C mixing device will not be installed in the
system, which ensures a return water temperature to the boiler of at least 60 ° C during
operation,
• a functional thermostatic valve will not be installed on t
he aftercooling circuit of the boiler
connected to the cooling water source, (eg aftercooling valve BVTS 3/4)
• the boiler is not installed according to the technical requirements stated in this manual, such
as e.g. correct dimensions of the chimney, etc.
• is not adequately cleaned according to the instructions in this manual.
This appliance is not intended for use by persons (including children) with physical, sensory or
mental disabilities or lack of experience and knowledge of safe use, unless they have been
given supervision or instruction concerning use of the appliance by a person responsible for
their safety. Children should be supervised to ensure that they do not play with the appliance.
If the power cord is damaged, it must be replaced with the correct type of cord!
Be careful when working with the appliance! The lambda probe works at high temperatures
(300 °C) and there is a risk of burns if handled carelessly!
TECHNIC DESCRIPTION
The boiler is designed for wood combustion, on the principle of gasification with the use of an
exhaust fan, which creates a forced flow in the elbow and sucks flue gases from the boiler. The
boiler body is made as a weldment from 6 mm thick steel sheets. In the upper part of the boiler
there is a loading chamber, equipped with dry jacket technology, which reduces the formation
of condensate and thus prolongs the life of the boiler. In the lower part of the loading chamber
there is a refractory concrete nozzle with a longitudinal hole for the passage of wood gas into the
combustion chamber. Secondary air is supplied in the nozzle, which, when mixed with wood gas,
produces combustion in the combustion chamber. Combustion residues (ash) accumulate in the
combustion chamber. The ashtray is located under the combustion chamber. In the rear part of
the boiler body, the tubular exchanger is equipped with combined turbulators (flue gas brakes),
which are used to clean the exchanger and increase the efficiency of the boiler. Turbulators with
cleaning springs are controlled by a lever on the side of the boiler. In the upper part of the boiler
there is a boiler control, which controls the wood gasification process and provides all important
information about the operation of the boiler. The extraction of flue gases during application is
solved by an exhaust channel in the upper part of the combustion chamber and opens directly
into the chimney, which bypasses the exchanger. The boiler is designed for a long combustion
time depending on the output, and therefore it is necessary to connect it with the buffer tank.