28
Engl
is
h
YES
YES
NO
NO
•
The connected 230V equipments are not working:
Does the voltmeter
indicate voltage?
Is the thermal protection in
the OFF position?
Place it in the "ON" position
Check if the plugged
equipment is malfunctioning.
Possible causes to check in this order
Loose cable or connector
Brushes in poor condition
Damaged voltage
regulator.
Visually check the
equipment and control
panel wiring.
Replace brushes
MG3000 part 105 in drawing
MG5500 part 111 in drawing
MG6200 part 111 in drawing
Replace the voltage
regulator.
MG3000 part 103 in drawing
MG5500 part 118 in drawing
MG6200 part 118 in drawing