-21-
7
Troubleshooting
The determination of the causes of
existing defects and their elimination
always require increased attention
and caution. Pull out the mains plug
before hand!
A decrease in vacuuming capacity may result from a
number of different causes:
Container or filter bag 8 (Fig. 4 - page 3) must
be emptied, cleaned off or replaced.
Fold filter 5 (Fig. 2 - page 3) is heavily soiled. Clean
as described under section 5.2. After long use and
frequent cleaning, the permeability of the filter may
be reduced in a way that it must be replaced.
Motor protection filter 6 heavily soiled.
Connecting hose blocked.
If the decreased vacuuming capacity is not caused
by any of the reasons listed, do not make any further
attempts to pinpoint or repair it. Electrical safety can
be negatively affected if the device is tampered with
improperly.
Take the device to a MAFELL customer service
shop.
8
Optional accessories
Transport case «MAX». Size IV
Ref. No. 095 044
Filter bag set, 5 pieces (for 50 l container)
Ref. No. 093 677
Filter bag set, 5 pieces (for 25 l container)
Ref. No. 093 678
1 pair of fold filter cartridges (cellulose)
Ref.-No. 093 673
1 pair of fold filter cartridges (polyester)
Ref.-No. 093 674
4 m connecting hose, LW21 machine connection Ø
35 mm (1 3/8 in.) anti-static
Ref. No. 093 679
4 m connecting hose, LW27 machine connection Ø
35 mm (1 3/8 in.) anti-static
Ref. No. 093 684
5 m connecting hose, LW35 machine connection Ø
35 mm (1 3/8 in.) anti-static
Ref. No. 093 681
2.5 m connecting hose, LW49 machine connection Ø
58 (2 1/4 in.) mm static
Ref. No. 093 682
4 m connecting hose, LW27 machine connection Ø
35 (1 3/8 in.) mm static
Ref. No. 093 680
Hand extraction set
Ref. No. 093 694
9
Exploded drawing and spare parts list
The corresponding information in respect of spare parts can be found on our homepage: www.mafell.com
Summary of Contents for S 25 M
Page 4: ......