Maestrogen Ultra Slim LED Illuminator Instruction Manual Download Page 4

 

www.maestrogen.com

 

SPECIFICATIONS

 

 

Dimensions

 

(mm):

 

210D

 

x

 

210W

 

x

 

30H

 

 

Viewing

 

surface

 

(mm):

 

120

 

x

 

70

 

 

Wavelength

 

(nm):

 

470

 

 

Amber

 

filter:

 

amber

 

filter

 

shield

 

with

 

metal

 

frame

 

 

LED

 

arrangements:

 

matrix

 

for

 

two

side

 

illumination

 

 

LED

 

lifetime:

 

50,000

 

hours

 

 

Power:

 

24V

 

DC

 

1

 

A

 

power

 

adaptor

 

 

Compatible

 

with

 

mini

 

gel

 

size

 

(mm):

 

110

 

x

 

60

 

&

 

55

 

x

 

60

 

 

Weight

 

(Kg):

 

2.3

 

 

INSTALLATION

 

Carefully

 

unpack

 

the

 

illuminator

 

and

 

the

 

shield

 

as

 

follow:

   

1.

   

First

 

remove

 

the

 

bubble

 

material

 

at

 

the

 

top.

 

2.

   

Remove

 

the

 

illuminator

 

from

 

the

 

two

 

bubble

 

material

 

shells

 

and

 

place

 

it

 

on

 

a

 

stable,

 

horizontal

 

surface.

   

3.

   

Remove

 

the

 

plastic

 

protection

 

film

 

from

 

the

 

transparent

 

glass

 

viewing

 

surface

 

and

 

the

 

amber

 

filter.

 

 

Stand

 

alone

 

installation

   

1.

   

The

 

instrument

 

must

 

be

 

placed

 

on

 

a

 

bench

 

leaving

 

at

 

least

 

10

 

cm

 

of

 

space

 

all

 

around

 

in

 

order

 

to

 

avoid

 

any

 

obstacle

 

that

 

may

 

reduce

 

the

 

ventilation.

   

2.

   

Connect

 

the

 

instrument

 

to

 

the

 

power

 

using

 

the

 

annexed

 

cable.

 

The

 

power

 

font

 

must

 

be

 

able

 

to

 

deliver

 

at

 

least

 

250

 

VA

 

with

 

a

 

voltage

 

between

 

100

 

and

 

240

 

Vac.

 

The

 

plug

 

must

 

have

 

a

 

ground

 

connection.

 

The

 

adaptor

 

supplies

 

24

 

V

 

DC

 

voltage.

 

   

Installation

 

with

 

the

 

Standard

 

Documentation

 

System:

   

This

 

instrument

 

has

 

been

 

designed

 

to

 

work

 

with

 

the

 

Standard

 

Documentation

 

System.

     

In

 

this

 

case

 

follow

 

the

 

instructions

 

included

 

in

 

the

 

Standard

 

Documentation

 

manual

 

or

 

any

 

other

 

instrument

 

that

 

will

 

be

 

released

 

in

 

the

 

future.

 

 

GENERAL

 

PRECAUTIONS

 

∙   

Plug

 

the

 

illuminator

 

on

 

an

 

electric

 

line

 

with

 

ground

 

connection.

   

∙   

The

 

illuminator

 

is

 

equipped

 

with

 

thermal

 

protection

 

to

 

prevent

 

overheating.

 

∙   

Do

 

not

 

pour

 

liquids

 

directly

 

on

 

the

 

illuminator.

 

Reviews: