When purchased from eGauge Systems, the Maestro E206XT is pre-configured for the T-Mobile
network, along with both Ethernet ports configured for LAN access. In the event the Maestro is re-
configured or factory reset and must have the eGauge configuration applied, follow these
instructions.
1. Perform a factory reset, if not already done.
2. Power up the E206XT using the included power supply.
3. Using an Ethernet cable, connect a computer to port LAN1 on the E206XT. Make sure all
forms of wireless communication are disabled on the computer.
4. Open a web browser and navigate to 192.168.1.1. Log in using "admin" for both
username and password.
Verify and update firmware
5. Navigate to Status -> Overview. Look at Firmware Version under the System
section. If at 2.0.1 RC7, skip to Install Configuration File. (Warning: firmware 2.1.1
RC6 is unstable and must not be used).
6. Download maestro-e206-v201RC7-15122015.bin which is found attached to this
article. Alternatively, download from
.
7. Navigate to System -> Backup/Flash firmware. In Flash new firmware image,
choose maestro-e206-v201RC7-15122015.bin and press Flash image. The
checksum should validate to fc06331a0057750b716044757ed470ab.
8. When finished the device will reboot. Restart at step 4 to ensure new firmware took effect.
Install configuration file
9. Download backup-Maestro-2017-02-24.tar.gz from this article.
10. Navigate to System -> Backup/Flash firmware.
11. In the Backup / Restore section, choose backup-Maestro-2017-02-24.tar.gz and
press Upload archive.
12. The unit will reboot after installing the configuration. You can ensure the settings took
affect by logging into the Maestro, clicking Next on the Quick Setup wizard, and ensuring
under the Cellular section that APN is set to fast.t-mobile.com
Reset and connect to Maestro unit