5.5 Parameter setting 

Under OFF mode, hold 

  for 3 seconds to enter parameter settings. 

Parameter 

Description 

Default setting 

Setting range 

Priming time 

1 minutes 

0~10min, by 1 minute increments 

Minimum RPM 

1200rpm 

1200~2000rpm, by 100rpm increments 

Di2 

2900 rpm 

1200~2900rpm, by 100rpm increments 

Di3 

2400 rpm 

1200~2900rpm, by 100rpm increments 

Di4 

1200 rpm 

1200~2900rpm, by 100rpm increments 

Priming RPM 

2900 rpm 

1200~2900rpm, by 100rpm increments 

 
 
 

6.  PROTECTION & ERROR CODES 

Item 

Code 

Description 

Analysis 

E001 

Abnormal input voltage 

Not faulty 

E002 

Output over current 

Not faulty 

E101 

Heat sink over heat 

Contact your supplier 

E102 

Heat sink sensor error 

Contact your supplier 

E103 

Master driver board error 

Contact your supplier 

E201 

Circuit board error 

Contact your supplier 

E202 

Master board EEPROM reading failure 

Contact your supplier 

E203 

RTC time reading error 

Contact your supplier 

E204 

Keyboard EEPROM reading failure 

Contact your supplier 

10 

E205 

Communication error 

Contact your supplier 

11 

AL01 

Auto speed reduction against high temperature 

Contact your supplier 

 
Note

:   

1. AL01 is not an error indication: when it appears the inverter will automatically switch to a 
lower  speed  to  self  protect  against  high  internal  temperature.  When  the  temperature  drops 
back  to  normal  operating  range  (65

)  the  inverter  will  resume  at  the  preset  speed.  If  this 

happens often please check correct ventilation requirements and move out of direct sunlight. 
 
2. If code E002/E101/E103 occurs, and the cause for the code appearing is cleared. I.e E101 
heat sink is within normal operating range again the device will resume working automatically, 
however  when  it  appears  a  fourth  time,  the  device  will  stop  working  and  display  the  code 
continuously, to resume operation, disconnect power to the device by unplugging and power 
restart again. 
 
 

If code continues to be displayed please contact the Madimack support line on 

1300 899 737 or email [email protected] 

 

Summary of Contents for INVPLUS1100

Page 1: ...INVERTER INSTALLATION USER GUIDE INVPLUS1100 INVPLUS2200 Thank you for purchasing our variable speed pump controller Please read the manual carefully before installation operation and keep it for future reference after installation ...

Page 2: ......

Page 3: ...G TO POOL PUMP 3 5 SETTINGS OPERATION 4 6 PROTECTION ERROR CODES 7 7 COMMISSIONING AND CHECKS 8 8 EXCLUSIONS 8 9 WARRANTY 8 10 RECYCLING 8 SAFETY SYMBOLS Read and keep the manual in a safe place Warning Caution Risk of electrical shock Do not touch the heat sink e Waste Dispose at recycling centre ...

Page 4: ... typical single speed swimming pool pump motor Fig 1 1 1 It is NOT compatible with a Single phase motors with centrifugal switch b Pool pump motors with start relays or switch c Series or DC motors d Pool pump motors with faults in their rotors or capacitors e Shaded pole asynchronous motors 1 2 An RCD with a rated residual current not exceeding 30mA must be used with this product Running Capacito...

Page 5: ...f the inverter Fig 2 Model INVPLUS1100 INVPLUS2200 Dimensions Input power 1 phase AC 1 phase AC Input voltage 220 240V 220 240V Input frequency 50Hz 50Hz Output power Max 1 1kW Max 2 2 kW Output Voltage 1ph 0 240V 1ph 0 240V Pump type Single phase Single phase Max current Max 6A Max 12A Speed range 1200 2900 rpm 1200 2900 rpm Cooling Ventilation Ventilation Fan Net Dimension L H W 187 110 155mm 18...

Page 6: ...crews 4 1 Turn off all electrical supply to the pool pump unplug the pool pump it from the main switch or at the chlorinator which provides electrical power to the pump 4 2 Plug the pool pump into the device s Power socket see fig 3 below PUMP CONNECTION ONLY 4 3 Plug the device into the main switch chlorinator timer connection where the pump was originally plugged into 4 4 Switch power back on 4 ...

Page 7: ...ock the screen Press to start Upon starting pump will run at maximum speed of 2900 rpm for one minute self priming This can be increased to 10 minutes see Parameter settings Section 5 5 After self priming press to choose a running speed use or arrows to adjust by 50rpm increments to a specific running speed Once the pump has finished priming the inverter will automatically switch the pump to the p...

Page 8: ...ds to save settings automatically A flashing indicates the device is waiting for start time Step5 press to check all 4 timers to ensure there are no invalid setting Note If inactivate for 1 minute the screen will lock automatically Hold for 3 seconds to unlock the device The device has power off memory operation will resume upon power restoration Under OFF mode hold for 3 seconds to retrieve facto...

Page 9: ... 3 4 to COM Do not touch the heat sink while the device is in operation or until at least 30 mins after it has been switched off Keep it out of reach of children Because of high voltage conversion components contained in the device do not try to disassemble or replace any components in case of malfunction or breakdown Before serving on the unit wait till the power light turned off or at least 3 mi...

Page 10: ...ng error Contact your supplier 9 E204 Keyboard EEPROM reading failure Contact your supplier 10 E205 Communication error Contact your supplier 11 AL01 Auto speed reduction against high temperature Contact your supplier Note 1 AL01 is not an error indication when it appears the inverter will automatically switch to a lower speed to self protect against high internal temperature When the temperature ...

Page 11: ...e product its performance or the contents of the User Guide without notice in case of technical upgrade Madimack are not responsible for the failure of any pump connected to the device The variable speed controller should not be installed in exposed locations or corrosive environments 9 WARRANTY The Madimack variable speed pump controller is warrantied for manufacturing defect for up to 12 months ...