Fuel Tank
Fill the tank daily or as required with diesel fuel. Location of the filler cap is on the top
of the tank at the rear of the upper grated platform. Ensure adequate fuel level is
maintained.
Hydraulic Oil Tank
Check this daily for oil level. A sight glass is provided and located on the side of the
hydraulic tank. Clean hydraulic oil should be added via the hand pump and wand
assembly on the side of the hydraulic tank. Never overfill the system.
Never run the
machine with low oil because this may damage the pumps
.
Urea (DEF) Tank
Top up the DEF tank with every fuel fill; only use AddBlue/DEF meeting ISO-22241
specification. Store DEF out of direct sunlight where temperatures
Do NOT
exceed 35
deg. C. DEF is very corrosive, contact with the solution can cause irritation. When
handling wear gloves, change gloves and clothes if spillage occurs.
Note:
Upon engine shut down DEF pump will evacuate fluid out of system to prevent
freezing and solution spoiling.
Do NOT
disconnect power before the completion of this
process which can take up to 2 minutes (see Night Switch Operation).
Engine Crankcase
Check the level of the engine oil daily and add the proper oil as necessary (see the
manufacturer
’s recommendations).
Never operate the engine with low oil.
Change
the oil filter at every oil change.
Radiator
Check the coolant level daily. Be sure to use the appropriate coolant mixture in cold
weather. Consult the engine manufacturer
’s recommendations. Change the coolant
and flush the system as per lubrication & maintenance chart. Keep the radiator and oil
cooler fins clean so that the cooling system may operate efficiently. Refer to the
engine manufacturer
’s manual for specific information on engine coolant and service.
Batteries
Check the water level of both batteries weekly. If it is necessary to fill the battery, use
distilled water only.
DO NOT USE TAP WATER
as it may contain minerals which will
contaminate the electrolyte
.
Batteries are located on the floor in the cab riser.
Summary of Contents for 3000
Page 1: ...3000 4000 LOG LOADER OPERATION MAINTENANCE MANUAL ...
Page 7: ...4 GENERAL LAYOUT ...
Page 26: ...23 INTERFACE WARNING LIGHTS Main Display ...
Page 38: ...35 ...
Page 39: ...36 3000 Log Loader Service Lubrication Chart ...
Page 40: ...37 4000 Log Loader Service Lubrication Chart ...
Page 43: ...40 ...
Page 44: ...Madill Equipment 9896 Galaran Road P O Box 2128 Sidney BC Canada V8L 3S6 ...