MadgeTech PR2000 Product User Manual Download Page 10

PR2000

10

Recalibration

The PR2000 standard calibration is dependant upon the range. 

 

Additional:

Custom calibration and verification point options available, please call for pricing.

 
Call for custom calibration options to accommodate specific application needs.
Prices and specifications subject to change. See MadgeTech’s terms and conditions at 

www.madgetech.com

To send devices to MadgeTech for calibration, service or repair, please use the MadgeTech RMA Process by visiting  

www.madgetech.com

, then under the services tab, select RMA Process.

            BATTERY WARNING

This data logger contains a lithium battery. Do not cut the battery open, 
incinerate, or recharge. Do not heat lithium batteries above the specified operating 

temperature.* Dispose of the battery in accordance with local regulations.

*See the individual specification sheets at www.madgetech.com.

Battery Information

Device Maintenance

Materials:

 

3/32” HEX Driver (Allen Key) and a Replacement Battery (U9VL-J)

- Remove the back cover from the device by unscrewing the four screws.
- Remove the battery from its compartment and unsnap it from the connector.
- Snap the new battery into the terminals and verify it is secure.

 - Replace the cover taking care not to pinch the wires. Screw the enclosure back together. 

 

Note: Be sure not to over tighten the screws or strip the threads.

For any other maintenance or calibration issues, we recommend the unit be returned to the 
factory for service. Before returning the device, you must obtain an RMA from the factory.  

Battery Replacement

This product does not have any user-serviceable parts except the battery which should be 
replaced periodically. The battery life is affected by battery type, ambient temperature, 
sample rate, sensor selection, off-loads and LCD usage. The device has a battery status indi-
cator on the LCD. If the battery indication is low, or if the device seems to be inoperable, it 
is recommended that the battery be replaced.

Summary of Contents for PR2000

Page 1: ...PR2000 Red 485 Dark Blue Pantone 289 Light Blue 58 of Pantone 289 PR2000 Pressure Data Logger with LCD Product User Guide...

Page 2: ...eTech product line visit our website at www madgetech com Quick Start Steps 3 Product Overview 4 Software Installation 5 Device Operation 5 Computer Interface 6 Front Panel Overview 7 Screen Descripti...

Page 3: ...old separately 4 Launch the MadgeTech 4 Software The pHTemp2000 will appear in the Connected Devices window indicating the device has been recognized 5 Select the start method reading rate and any oth...

Page 4: ...e statistics A trending graph is also displayed of the last 100 readings Please refer to the PR2000 Product Manual for full product details by going to www madgetech com product documentation LED Indi...

Page 5: ...ogger For most applications select Custom Start from the menu bar and choose the desired start method reading rate and other parameters appropriate for the data logging application and click Start Qui...

Page 6: ...nto the female receptacle of the data logger Fully insert the female USB connector into the USB Please see the Data Logger Software manual for further information WARNING Install driver before connect...

Page 7: ...s screens then press F2 to view memory status information Button pressing chain Main Screen F1 F2 Checking power status A battery status and external power status if available icon appear on all scree...

Page 8: ...ns Run Parameters Statistics Menu Screen Displays options available within the statistics menu Type Statistics Displays statistics from the pressure channel Memory Status Channel Statistics Displays s...

Page 9: ...ns Hardware and Power Interruption Power Interruption Displayed as notification when power is interrupted during device operation F1 OK accepts notification and displays main screen F2 no function F3...

Page 10: ...rmation Device Maintenance Materials 3 32 HEX Driver Allen Key and a Replacement Battery U9VL J Remove the back cover from the device by unscrewing the four screws Remove the battery from its compartm...

Page 11: ...110 Baud Rate 115 200 Typical Battery Life 1 year battery life at 1 minute reading rate with display off 30 days typical with continuous display use Operating Environment 20 C to 60 C 4 F to 140 F 0 R...

Page 12: ...MadgeTech Inc 6 Warner Road l Warner NH 03278 Phone 603 456 2011 l Fax 603 456 2012 www madgetech com l info madgetech com DOC 1148036 00 REV 12 2017 03 27...

Reviews: