background image

pHTemp2000

Red 485
Dark Blue Pantone 289
Light Blue 58% of Pantone 289

pHTemp2000

pH and Temperature Data Logger with LCD 

Product User Guide

Summary of Contents for pHTemp2000

Page 1: ...pHTemp2000 Red 485 Dark Blue Pantone 289 Light Blue 58 of Pantone 289 pHTemp2000 pH and Temperature Data Logger with LCD Product User Guide...

Page 2: ...oftware Installation 5 Device Operation 5 6 Computer Interface 6 Front Panel Overview 7 Screen Descriptions 8 9 Device Maintenance 10 General Specifications 11 Table of Contents To view the full Madge...

Page 3: ...n recognized 5 Select the start method reading rate and any other parameters appropriate for the desired data logging application Once configured click the Start icon and deploy the data logger 6 To d...

Page 4: ...s Delay start Wait Icon device is busy Device reset has occurred External power present Product Overview The pHTemp2000 is a pH and temperature data logger with LCD display The convenient LCD provides...

Page 5: ...or an appropriate adapter Select a probe with an output impedance less than 300 megaohms at the desired tem perature 2 The temperature probe must be a 100 platinum RTD in the standard 2 3 or 4 wire co...

Page 6: ...rt method 6 Disconnect the data logger from the interface cable and place it in the environment to measure Note The device will stop recording data when the end of memory is reached or the device is s...

Page 7: ...d F2 to the pH probe Pressing these function keys will cause the channels to scroll between show or hide channels displaying show will appear on the main screen and channels displaying hide will not A...

Page 8: ...and Time Statistics Statistics Menu Screen Displays options available within the statistics menu pH Channel Statistics Displays pH statistics Type Statistics Displays statistics from pH statistics Te...

Page 9: ...ardware and Power Interruption Power Interruption isplayed as notification when power is interrupted during device operation F1 OK accepts notification and displays main screen F2 no function F3 no fu...

Page 10: ...ww madgetech com Battery Information Materials 3 32 HEX Driver Allen Key and a Replacement Battery U9VL J Remove the back cover from the device by unscrewing the four screws Remove the battery from it...

Page 11: ...145 40 C to 110 C 40 F to 230 F Temperature Resolution 0 001 0 01 C 0 018 F Calibrated Accuracy 0 015 0 04 C 0 072 F Memory 131 071 channel Reading Rate 1 reading every 2 seconds up to 1 reading every...

Page 12: ...MadgeTech Inc 6 Warner Road l Warner NH 03278 Phone 603 456 2011 l Fax 603 456 2012 madgetech com l info madgetech com DOC 1176036 00 REV 12 2019 02 01...

Reviews: