3. Constant Voltage Specifications 

Model 

Voltage Stability 

Load Stability 

Ripple and Noise 

TPR-3C Series 

0.01&±2mV 

0.01&±2mV 

1mVrms 

(effective 

value)

 

 
 

4. Constant Current Specifications

 

Model

 

Voltage Stability

 

Ripple and Noise

 

TPR-3C Series 

0.2&±3mA 

3mArms 

 

Operation Instructions 

 

1.

 

Notice 

(1)

 

AC Input 

AC Input should be 110V±1% and 60Hz 

(2)

 

Heat Radiator 

The heat sink radiator is located at the back of the power supply.  Enough space 
should be left for heat dispensing. Do not use the power supply where the ambient 
temperature exceeds 40ºC 

 

2.

 

Operations 

 

Plug the AC power input 

 

Turn on the power switch “ON”  

 

Adjust the VOLTAGE(master and slave) to the desired value 

 

Connect the external load to the “+” and “-” terminals. 

 

When the power supply is used with an unstable load, either the output terminal 
“+” or “-” should be reliably connected to the GND terminal(depending the output 
is used in positive or negative mode) to decrease the ripple on the output voltage. 

 

Setting of Constant Current 
First make sure the maximum load current; then use a short-circuit wire to 
directly short the output terminal (+) to (-), and adjust the current control knob 
clockwise to the desired value; finally take off the short-circuit wire; adjust the 
Voltage knob to the desired value. 

 

 

Independent mode 

Set both of the mode switches at the up position. 
If used in constant voltage mode, turn both of the current knobs clockwise to the 
maximum. Adjust the voltage knobs to the desired values. 
If used in constant current mode, turn the voltage knobs clockwise to the maximum. 
Adjust the current knobs to the desired values. 
 

Serial mode 

Set the left mode switch to down and right mode switch to up positions. Turn the 
current knobs clockwise to the maximum, adjust the master channel (right) voltage 