Macurco Gas Detection Product limited warranty 

Macurco warrants the GBC gas detector will be free from defective materials and workmanship for a period of two (2) 

years from the date of manufacture (indicated on inside cover of the GBC), provided it is maintained and used in 

accordance with Macurco instructions and/or recommendations. If any component becomes defective during the 

warranty period, it will be replaced or repaired free of charge, if the unit is returned in accordance with the instructions 

below. This warranty does not apply to units that have been altered or had repair attempted, or that have been 

subjected to abuse, accidental or otherwise. The above warranty is in lieu of all other express warranties, obligations 

or liabilities. THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR PURPOSE ARE LIMITED 

TO A PERIOD OF TWO (2) YEARS FROM THE PURCHASE DATE. Macurco shall not be liable for any incidental or 

consequential damages for breach of this or any other warranty, express or implied, arising out of or related to the 

use of said gas detector. The manufacturer or its agent’s liability shall be limited to replacement or repair as set forth 

above. Buyer’s sole and exclusive remedies are the return of the goods and repayment of the price, or repair and 

replacement of non-conforming goods or parts. 

 

*Modbus is a trademark or registered trademark of Schneider Automation Inc. 

 

Macurco Gas Detection 

3601 N. St. Paul Avenue 

Sioux Falls, SD 57104 

 

Technical Support Contact Information 

Phone:

 1-844-325-3050 

Fax:

 1-605-951-9616 

Email:

 [email protected] 

Website:

 www.macurco.com/support/ 

General Contact Information  

Phone :

 1-877-367-7891 

Fax :

 1-605-951-9616 

Email:

 [email protected] 

Website:

 www.macurco.com  

 

 

REV – 1.1  

Issue Date: 3-3-2022 

Document No: 34-2900-0690-7      

© Aerionics 2022. All rights reserved.  

Macurco is a trademark of Aerionics, Inc. 

 

 

Summary of Contents for GBC-2-24

Page 1: ...IMPORTANT Keep these user instructions for reference Macurco GBC Gas Boiler Controller Installation Operation Manual...

Page 2: ...e wires to terminals 8 3 2 2 Terminal Connection 9 4 Operations 14 4 1 Power up 14 4 2 GBC Configuration 14 4 2 1 GBC Buzzer and Relay Settings 14 4 3 Programming on detectors to work with the GBC 17...

Page 3: ...e detector or up to four gas detectors the controller can control up to eight dry contact outputs These outputs are designed to shut down the boiler system upon the detection of carbon monoxide and or...

Page 4: ...p to 4 Expansion Relay Boards 24 VDC driver for horn strobe 250 mA Audible Buzzer 90 dBA at 1ft Output power supports combinations of 1 to 4 detector s 350 mA 2 4 Specifications Size 8 x 6 x 3 22 9 X...

Page 5: ...o GBC enclosure has 6 mounting holes and is shipped with mounting screws Install the mounting screws on the four corners of the enclosure The GBC should be mounted with sufficient space all round for...

Page 6: ...Macurco GBC Manual REV 1 2 34 2900 0690 7 6 P a g e Figure 3 2 Enclosure Dimensions...

Page 7: ...Macurco GBC Manual REV 1 2 34 2900 0690 7 7 P a g e Figure 3 3 Mounting dimensions...

Page 8: ...button of the connector 3 Fully insert the bare wire into the wire cavity of the connector Note When inserting the wire make sure that the wire insulation is not inhibiting the wire from contacting t...

Page 9: ...Macurco GBC Manual REV 1 2 34 2900 0690 7 9 P a g e 3 2 2 Terminal Connection Refer to Figure 3 4 below for location of different connectors in GBC Figure 3 4 GBC Board Diagram...

Page 10: ...et meters 18 500 152 16 800 244 14 1250 381 Table 3 1 Recommended Wire Gauge Note Only connect the GBC to Class 2 power supply Note It is recommended to use an independent transformer for powering the...

Page 11: ...Macurco GBC Manual REV 1 2 34 2900 0690 7 11 P a g e Figure 3 6 Single Sensor Channel Wiring...

Page 12: ...Macurco GBC Manual REV 1 2 34 2900 0690 7 12 P a g e Figure 3 7 Dual Sensor Channel Wiring...

Page 13: ...e connections Each terminal can accommodate a wire size from 12 to 24 AWG Each relay PCBS are labels NO1 COM1 and NC1 for Relay 1 and NO2 COM2 and NC2 for relay 2 See Figure 3 8 To use relay 1 connect...

Page 14: ...activated for 10 seconds and the fan relay for 60 seconds during the power up cycle The indicator light LED will flash green during the self test cycle If 4 20 mA setting is set to EnH CM xx will tran...

Page 15: ...f jumper is enabled and external horn strobe will be engaged during activation from the connected sensors o Jumper position 2 3 Split All populated relays 1 through 4 will activate simultaneously base...

Page 16: ...Macurco GBC Manual REV 1 2 34 2900 0690 7 16 P a g e Figure 4 3 Relay Designation...

Page 17: ...return to PUt in the Con menu Push Next until End is displayed then push Enter to get back to normal operation 4 3 2 Alarm Relay Configuration Arc To select the Alarm Relay Configuration in normal mo...

Page 18: ...nd push Enter again to return to Frd in the Con menu Push Next until End is displayed then push Enter to get back to normal operation 4 3 5 Fan Relay Latching Setting FrL To select the Fan Relay Latch...

Page 19: ...Figure 3 3 Mounting dimensions 7 Figure 3 4 GBC Board Diagram 9 Figure 3 5 GBC Board Diagram 10 Figure 3 6 Single Sensor Channel Wiring 11 Figure 3 7 Dual Sensor Channel Wiring 12 Figure 3 8 Relay PC...

Page 20: ...FOR PARTICULAR PURPOSE ARE LIMITED TO A PERIOD OF TWO 2 YEARS FROM THE PURCHASE DATE Macurco shall not be liable for any incidental or consequential damages for breach of this or any other warranty e...

Reviews: