Maco TRONIC 480525 Operating Instructions Manual Download Page 2

www.maco.eu

+

+

1x / ∼2 sec

+

+

+

1x

1x

3x

1 sec

1 sec

3x

1x

1x

Operating instructions

Test Device Tronic for EnOcean Wireless, Item no. 480525

Intended use:

The test device (A) is used for the 

functional testing (see Block I) 

of the MACO wireless sensors eTronic (EEP A5-14-01) and  
mTronic (EEP A5-14-0A). 
Together with the test transmitter (B), the test device can also be 
used to test the 

ranges (see Block II)

 of the EnOcean signal in a 

certain room / area. 

Any other use is not planned for and also not permitted!

Order No. 759384 / EN
Created: 05/2022 - changed: 04.07.2022 
All rights and amendments reserved.

Scope of delivery

Power supply

Test device (A)

Test transmitter  (B)

USB cable (C)

USB cable

Operation and display

Switch on

Self-test (diodes and battery status)

(~ 5 sec.)

(short keystroke)

Self-test 

finished

Manual power off or automatic shutdown

 

(~9 minutes of inactivity)

(long keystroke)

(4 red LEDs + acoustic signal)

Standby mode

I)  Check sensor signals (contact status) 

Switch off the test transmitter, only one sensor may 

be active!

II) Check signal range (with test transmitter)

Lock mode after alarm / sabotage must be reset on 
the mTronic (see package leaflet)!

1.  Switch on the test transmitter and 

place it in the window rebate or in 
the intended place of assembly.

Alarm / Sabotage

Operate window / 
door using handle

Test device display

1.  Lock status sensor or 

Alarm signal (mTronic only)

2.  Battery Status / 

Signal Quality

1x / 3 sec.

1x / 1 sec.

Change reception quality (to reduce the external influence of

 

sensors in the environment)

Additional information on the sensors: 

-   Wait for display of lock status sensor & battery status sensor, then 

query additional handle position / sensor function.

-   After a battery or mode change on the sensor, some complete 

movements (Closed / Open / Tilted) must be carried out until the 
test device displays the window status correctly again!

2.  Slowly back away from the test 

transmitter with the test device 
 
Signal strength is signalled via 
LEDs and acoustic signal.

3. Turn off the test transmitter.

4.  Exit test transmitter mode (short 

button press on the test device).

Dispose of in accordance with local regulations 
and laws!

Battery status is shown during the self-test when switched on.

3x AA 1,5 V Mignon
(not included)

or

1x 

  only signals with very good quality 

1x 

 

only signals with good quality or better

1x 

 

only signals with medium quality or better

1x 

 

all signals are accepted

Summary of Contents for TRONIC 480525

Page 1: ...e muss am mTronic zur ckgesetzt werden siehe Beipackzettel 1 Testsender einschalten und in Fensterfalz des Fensters legen bzw an den vorgesehenen Ort der Montage Alarm Sabotage Fenster T r mittels Gri...

Page 2: ...t be reset on the mTronic see package leaflet 1 Switch on the test transmitter and place it in the window rebate or in the intended place of assembly Alarm Sabotage Operate window door using handle Te...

Page 3: ...cendere il trasmettitore di prova e posizionarlo nella battuta della finestra o nel punto di installazione previsto Allarme Sabotaggio Azionare la maniglia della finestra porta Visualizzazione tester...

Page 4: ...1 Allumez l metteur de test et placez le dans la feuillure de la fen tre ou au point d installation pr vu Alarme Sabotage Actionnement de la poign e du Testeur de fen tres portes Testeur de dispositif...

Page 5: ...cienda el emisor de prueba y col quelo en el Aire de la ventana o en el lugar de instalaci n previsto Alarma Sabotaje Opere la ventana puerta con la manilla Informaci n en pantalla 1 Estado de bloqueo...

Page 6: ...testzender in en plaats deze in de raamsponning of op de beoogde installatieplaats Alarm Sabotage Raam deur door middel van greep bevestigen Weergave testapparaat 1 Vergrendel status sensor of alarmsi...

Page 7: ...hu sabot i je nutn na m Tronic resetovat viz p balov let k 1 Zapn te testovac vys la a um st te jej do falcu okna nebo na zam len m sto mont e Alarm Nepovolen manipulace Okno Dve e kliku oto it do st...

Page 8: ...instrukcja obs ugi 1 W cz nadajnik testowy i umie go we wn ce okiennej lub w przewidzianym miejscu monta u Alarm Sabota Okna Drzwi obs ugiwane za pomoc klamki Ekran testera 1 Stan czujnika ryglowania...

Reviews: