Service Instructions

To 

remove 

existing 

Register

assembly

Ensure  that  the  fluid  supply  to
the  meter  is  disconnected,  and
the  line  pressure  is  released

before  disassembly.

1] Remove the four screws  as

shown in Figure 1 below.

2] Remove the Register front cover

as shown in Figure 2 below.

3] Remove the 4 screws as shown

in Figure 3 below and remove
the register base.

Rotate  the  Cover  plate

1]Remove 6 Socket Head Cap screws

as shown in Figure 4.

2] Remove the Cover plate and

inspect the oring for damage,
replace if necessary.

3] Rotate the cover plate clockwise

one screw hole (60 degrees) as
shown if Figure 4.

4) Tighten the 6 Socket Head Cap

screws.

Dismantle  MH450  Register

Refer to the exploded parts diagram

Figure 7 for items numbers.

1] Remove the 4 clamp ring screws

(Item 1)

2] Remove the Clamp ring (Item 2)

3] Remove the Glass face and seal

assembly (Items 3 and 4)

4) Undo the two register Facia

screws (Item 5) and remove the
facia plate (Item 6)

Figure 1

Figure 2

Figure 3

Figure 4

Figure 5

Installing  the  MH450  Register

Refer to the exploded parts diagram

Figure 8 for items numbers.

1] Install the Gasket (Item 15)
2] Place register body (Item 11) into

position then fit the 4 register
mounting screws and tighten as

shown in Figure 6. 

Note:

 The

register body includes the
tumbler mechanism.

4) Replace the remaining items (6,

5, 4, 3, 2, 1) as per “Dismantle
MECH450 Register” instructions
above.

5) When fitting the clamp ring

(Item 2) tighten the 4 screws
evenly to avoid damage to the
glass.