MAINTENANCE

This meter has been designed for minimum maintenance. If 

you have a problem with this unit please contact you local 

Macnaught service centre or distributor.

TEST LCD 

Press both the ‘Total’ and ‘Reset’ buttons together for 

2 seconds. The system will then show the following 

information.

The LCD system check shows the following in sequence
1. Product name - ‘DI FLOW’
2. Softwear version - r1.0
3. Current unit of measure ‘Unit’ ‘Litres’
4. Current calibration factor (imp/L: ‘CAL’ ‘40.00’
5. Remaining voltage ‘bat Vol’’2.79’ 
    (if more than 2.8V will read ‘FULL’)
6. Battery capacity remaining e.g. ‘bat Per’’52.95’
    (only shown when voltage is less than 2.8 volts)

BATTERY REPLACEMENT

If remaining battery power is less than 0.9 Volt the battery 

icon will display (bottom right) and battery replacement is 

required.
1. Remove the 4 screws on the back of the meter.
2. Replace the 2 batteries (use 2 x AAA 1.5V Alkaline)
3. Refit the display (make sure not to damage the wires)
4. Carefully fit and tighten the 4 x screws 

Summary of Contents for ADTUM

Page 1: ...INSTRUCTION MANUAL ADTUM DIGITAL UREA DEF METER ADTUM im issue1 2015 ...

Page 2: ...s lighted cigarettes or gas or electric heaters Ensure that you follow all the correct earthing and grounding procedures before use Inspect seals and connections for leaks weekly when using flammable liquids Do not use Teflon tape on any connections when using flammable liquid Do not use this meter with gasoline or any fluid other than the compatible fluid specified in this manual Do not use the m...

Page 3: ...the totals the 5th volume is shown by pressing Total CALIBRATION INSTANTANEOUS FLOW RATE To show the instantaneous flow rate press and hold down the Reset button SELECT UNIT OF MEASURE Starting from the batch total screen 1 Press and hold down the Total button until Units appears Units will start flashing 2 Press Reset button the pre set units will be displayed 3 Press Total to scroll through to t...

Page 4: ...duct name DI FLOW 2 Softwear version r1 0 3 Current unit of measure Unit Litres 4 Current calibration factor imp L CAL 40 00 5 Remaining voltage bat Vol 2 79 if more than 2 8V will read FULL 6 Battery capacity remaining e g bat Per 52 95 only shown when voltage is less than 2 8 volts BATTERY REPLACEMENT If remaining battery power is less than 0 9 Volt the battery icon will display bottom right and...

Page 5: ...eplace batteries 2 Bad battery connection 2 Check battery orientation Inaccurate reading 1 Flow rate too high 1 Adjust flow rate to meter specifications 2 Incorrect calibration 2 Re calibrate meter 3 Air in the system 3 Re seal all connections 4 Dirty magnets 4 Clean magnets TROUBLE SHOOTING GUIDE Meter Type Turbine Flow rate 10 150ltr min Maximum pressure 3 5bar 50psi Accuracy 0 5 Power supply 2 ...

Page 6: ...6 macnaught instruction manual DIGITAL UREA DEF METER ADTUM INSTRUCTION MANUAL METER DIMENSIONS ...

Page 7: ...7 macnaught com au DIGITAL UREA DEF METER ADTUM INSTRUCTION MANUAL NOTES ...

Page 8: ...9 Henderson Street Turrella NSW 2205 Ph 1800 185 102 Fax 1800 186 402 E mail info macnaught com au For Warranty Terms and Conditions see www macnaught com au For a list of Australian Service Centres see www macnaught com au ...

Reviews: