E11
TECHNICAL DETAILS - OIL CONTROL VALVE
This manual contains important warnings and information.
Read and keep for reference.
Warning Symbol
This symbol alerts you to the possibility of serious injury or death if you do not follow the
instructions.
Caution Symbol
This symbol alerts you to the possibility of damage to or destruction of
equipment if you do not follow the instructions.
SAFETY PRECAUTIONS
EQUIPMENT MISUSE HAZARD
1. This equipment is for professional use only.
2. Read all instruction manuals, tags, and labels before operating the equipment.
3. Use the equipment only for its intended purpose. If you are not sure, call your distributor.
4. Do not alter or modify this equipment.
5. Check equipment daily. Repair or replace worn or damaged parts immediately.
6. Do not exceed the maximum working pressure of the lowest rated system component. This
equipment has a 1500psi (10Mpa, 100bar) maximum working pressure.
7. Use fluids and solvents which are compatible with the equipment wetted parts. Refer to the
Technical Data section of all equipment manuals. Read the fluid and solvent manufacturer’s
warnings.
8. Route hose away from traffic areas, sharp edges, moving parts, and hot surfaces.
9. Do not lift pressurized equipment.
10. Comply with all application local, state, and national fire, electrical, and safety regulations.
INJECTION HAZARD
Spray from the valve, leaks or ruptured components can inject fluid into your body and cause
extremely serious injury, including the need for amputation. Fluid splashed in the eyes or on
the skin can also cause serious injury.
1. Fluid injected into the skin might look like just a cut, but it is a serious injury. Get immediate
medical attention.
2. Do not point the valve at anyone or at any part of the body.
3. Do not put your hand or fingers over the grease fitting coupler.
4. Do not stop or deflect leaks with your hand, body, glove or rag.
5. Tighten all fluid connections before operating the equipment.
6. Check the hose, tubes, and couplings daily. Replace worn or damaged parts immediately.
Do not repair high pressure couplings; you must replace the entire hose.
Item No.
Inlet
Configure
Flow rate
Operating pressure range
Max operation temperature
Accuracy
Battery
18123522
1/2" NPT
Flexible nozzle, auto tip
1-35L/min
0.5-100bar
60°C
±0.5%
ER14250 3.6V