pattern. Time-Delay is added continually: When it receives the second induction signals
within the first induction, it will restart to time from the moment.
Adjustable Time Delay: the length of time delay could be set according to the customers’
requirement, the minimum time of this item is 10sec±3sec, and the maximum is
3min±30sec.
INSTALLATION:
Switch off the power. Unscrew the plastic screw nut and remove the PC
lampshade.Pass the wire through the hole in the bottom and connect the power wire
into connection-wire column according to the connection-wire diagram. Install the
sensor lamp in the position where you need with inflated screws. Switch on the power
and test it.
CONNECTION-WIRE DIAGRAM:
(look at illustration)
Note: Connect the electronic wire from battery with LED panel first, then continue to
connect the lamp with AC power
TEST:
Turn the TIME knob anti-clockwise on the minimum. Turn the LUX knob clockwise
on the maximum (sun). Switch on the power; the lamp will have no signal at the
beginning. After Warm-up 30sec, the lamp can start work .If it receives the induction
signal, the lamp will turn on. While there is no another induction signal any more, the
lamp should stop working within 10sec±3sec. Turn LUX knob anti-clockwise on the
minimum (moon). If the ambient light is more than 3LUX, the lamp should not work. If
the ambient light is less than 3LUX (darkness), the sensor would work. Under no
induction signal condition, the lamp should stop working within 10sec±3sec. Note:
when testing in daylight, please turn LUX knob to (SUN) position, otherwise the sensor
lamp could not work!
NOTE:
Should be installed by electrician or experienced person; Avoid installing it on the
uneven object; There should be no hindrance and moving objects in front of the
detection windows to affect detection; Avoid installing it near air temperature alteration
zones such as air condition, central heating, etc; Considering your safety, please do not
open the cover when you find the hitch after installation. If there is difference between
instruction and the function the product has, please give priority to product and sorry not
to inform you additionally.
SOME PROBLEM AND SOLVED WAY:
The load do not work:
a. Please check if the connection-wiring of power and load is correct.
b. Please check if the load is good.
c. Please check if the working light sets correspond to ambient light.
The sensitivity is poor:
a. Please check if there has any hindrance in front of the detection window to affect to
receive the signal.
b. Please check if the ambient temperature is too high.
c. Please check if the induction signal source is in the detection fields.
d. Please check if the installation height corresponds to the height showed in the
instruction.
e. Please check if the moving orientation is correct.
The sensor can not shut off the load automatically:
a. Please check if there is continual signal in the detection field.
b. Please check if the time delay is the longest.
PL
Lampa LED z czujnikiem podczerwieni (zasilanie awaryjne)
Wielofunkcyjny wyłącznik podtynkowy z czujnikiem ruchu wyposażony w detektor
podczerwieni o wysokiej czułości. MCE131 to urządzenie umożliwiające o szerokiej
funkcjonalności pozwalające zaoszczędzić energię elektryczną. Produkt umożliwia
automatyczne załączenie obciążenia, po wykryciu ruchu w polu detekcji, dzięki
czujnikowi na podczerwień. Dzięki czujnikowi światłoczułemu urządzenie można
ustawić tak, aby działało tylko o określonej porze dnia.
INFORMACJE TECHNICZNE:
Napięcie zasilania: 110-240V/AC
Zasięg detekcji: 6m max (<24°C)
Czujnik oświetlenia: 3-2000LUX (regulowany)
Czas załączenia: min: 10s±3s,
max.:3min±30sec
Obciążenie znamionowe: 12W (24szt. LED)
Wbudowana bateria: 3.7V/1500mAH
Czas świecenia w trybie awaryjnym: 3H
CECHY:
- Funkcja zasilania awaryjnego dzi
ęki wbudowanej baterii – do 3 godzin ciągłej pracy.
- Czujnik oświetlenia w zależności od potrzeby może zostać regulowany: pozycja
SŁOŃCE (max) –praca w dzień i nocy, KSIĘŻYC –praca w nocy przy poziome natężenia
rzędu ok. 3LUX.
- Regulacja czasu załączenia: w zależności od potrzeby może zostać ustawiona w
zakresie od 10s±3s do 15 min±2min. Timer jest resetowany za każdym razem kiedy
urządzenie wykryje ruch.
- Regulowany czas wyłączenia w przedziale 10sek-3min.
MONTAŻ:
Odłącz zasilanie. Odkręć plastikową śrubę i zdejmij lampę (patrz ilustracje).
Przełóż przewód poprzez otwór w spodzie i podłącz przewody zasilania zgodnie ze
schematem podłączenia. Przymocuj lampę w wybranym miejscu za pomocą kołków
rozporowych. Włącz zasilanie i sprawdź działanie lampy.
SCHEMIAT PODŁĄCZENIA.
(patrz ilustracje).
Uwaga:
Podłącz przewód baterii z
panelem LED przed podłączeniem zasilania sieciowego.
Pole detekcji: 360º
Temperatura pracy: -20~+40°C
Wilgotność pracy: <93%RH
Zalecana wysokość montażu:
max: 2.2m~4m
Prędkość wykrywanego ruchu:
0.6~1.5m/s
Pobór energii w trybie awaryjnym:
1.2W (6szt. LED)