Max.15min±2min
Rated Load:max 800W 400W
FUNCTION:
Can identify day and night: The consumer can adjust working state in different ambient
light. It can work in the daytime and at night when it is adjusted on the “sun” position
(max). It can work in the ambient light less than 3LUX when it is adjusted on the “3”
position (min). As for the adjustment pattern, please refer to the testing pattern.
Time-Delay is added continually: When it receives the second induction signals within
the first induction, it will restart to time from the moment.
INSTALLATION ADVICE:
As the detector responds to changes in temperature, avoid the following situations:
Avoid pointing the detector towards objects with highly reflective surfaces, such as
mirrors etc. Avoid mounting the detector near heat sources, such as heating vents, air
conditioning units, light etc. Avoid pointing the detector towards objects that may move
in the wind, such as curtains, tall plants etc.
CONNECTION:
Warning. Danger of death through electric shock! Must be installed by professional
electrician. Disconnect power source. Cover or shied any adjacent live components.
Ensure device cannot be switched on. Check power supply is disconnected.
Swing the plastic cover a little and adjust time and LUX knob. Loose the screws in the
connection terminal, and then connect the power to connection terminal of sensor
according to connection-wire diagram. Fold the metal spring of the sensor upwards, until
they are in “I” position with sensor, and then put the sensor into the hole or installation
box which is on the ceiling and has the similar size with the sensor. Releasing the spring,
the sensor will be set in this installation position. After finishing installing, turn on the
power and then test it.
CONNECTION-WIRE DIAGRAM:
(See the right figure)
TEST:
Turn the TIME knob anti-clockwise on the minimum (10s). Turn the LUX knob clockwise
on the maximum (sun). Switch on the power; the sensor and its connected lamp will
have no signal at the beginning. After Warm-up 30sec, the sensor can start work .If the
sensor receives the induction signal, the lamp will turn on. While there is no another
induction signal any more, the load should stop working within 10sec±3sec and the
lamp would turn off. Turn LUX knob anti-clockwise on the minimum (3). If the ambient
light is more than 3LUX, the sensor would not work and the lamp stop working too. If the
ambient light is less than 3LUX (darkness), the sensor would work. Under no induction
signal condition, the sensor should stop working within 10sec±3sec.
Note: when testing in daylight, please turn LUX knob to (SUN) position, otherwise the
sensor lamp could not work!
SOME PROBLEM AND SOLVED WAY:
The load does not work:
a. Please check if the connection of power source and load is correct.
b. Please check if the load is good.
c. Please check if the settings of working light correspond to ambient light.
The sensitivity is poor:
a. Please check if there is any hindrance in front of the detector to affect it to receive
the signals.
b. Please check if the ambient temperature is too high.
c. Please check if the induction signal source is in the detection field.
d. Please check if the installation height corresponds to the height required in the
instruction.
e. Please check if the moving orientation is correct.
The sensor can not shut off the load automatically:
a. Please check if there is continual signal in the detection field.
b. Please check if the time delay is set to the maximum position
c. Please check if the power corresponds to the instruction.
Installation Height: 2.2-4m
Detection Moving Speed: 0.6-1.5m/s
MCE130
PL
Czujnik ruchu PIR do zabudowy
Wielofunkcyjny wyłącznik podtynkowy z czujnikiem ruchu wyposażony w detektor
podczerwieni o wysokiej czułości. MCE130 to urządzenie umożliwiające o szerokiej
funkcjonalności pozwalające zaoszczędzić energię elektryczną. Produkt umożliwia
automatyczne załączenie obciążenia, po wykryciu ruchu w polu detekcji, dzięki
czujnikowi na podczerwień. Dzięki czujnikowi światłoczułemu urządzenie można
ustawić tak, aby działało tylko o określonej porze dnia.
INFORMACJE TECHNICZNE:
Napięcie zasilania: 220-240V/50Hz
Zasięg detekcji: 6m max (<24°C)
Czujnik oświetlenia: 3-2000LUX (regulacja)
Czas załączenia:
min: 10s±3s, max.:15min±2min
Obciążenie max.: 800W (lampy żarowe)
400W (lampy energooszczędne)
CECHY:
- Czujnik oświetlenia w zależności od potrzeby może zostać regulowany: pozycja
SŁOŃCE (max)–praca w dzień i nocy, KSIĘŻYC –praca w nocy przy poziome natężenia
Pole detekcji: 360º
Temperatura pracy: -20~+40°C
Wilgotność pracy: <93%RH
Zalecana wysokość montażu:
max: 2.2m~4m
Pobór mocy: 0.5W
Prędkość wykrywanego ruchu:
0.6~1.5m/s