Environmental - Storage and Operating Conditions 

 
The Mackworth SA180 is intended for internal use within normal environmental conditions.  
 

It is not intended to be used in environments where there are rapid changes in the environmental temperature and 
humidity during intended use. 

 

 

Normal Operating Conditions 

+5°C to +40°C (41°F to 104°F) at a relative humidity between 15% to 90% RH, non-condensing but not requiring a water vapour 
pressure greater than 50hPa and atmospheric pressure between 700hPa to 1060hPa. 

 

Shipping and Storage Conditions 

-25°C to +5°C (-13ºF to 41ºF) with any humidity level. 
+5°C to +35°C (41°F to 95°F)  at a relative humidity up to 90%.  
+35°C to 70°C 

(95⁰F to 158⁰F) 

non-condensing at a water vapour pressure up to 50hPa. 

 
 

 

Maintenance 

 

No service is to be carried out on the Mackworth SA180 while transferring a person to reduce the risk of injury.  
Service must be completed by a Prism Medical UK authorised Service Engineer.  
Do not attempt to service the product yourself, or warranty is void.  

 
To ensure the safety and continued good function of your Stand Aid, routine service must be performed on your Mackworth 
SA180 Stand Aid. 
Service should be completed by a Prism Medical UK approved service engineer every 6 months to ensure the products required 
standard is maintained. The service history of the product should be documented each service in the Service Log at the back of 
this User Manual.  
 

When the Stand Aid is serviced, the 6 month service checklist must be completed for the Mackworth SA180 Stand Aid.  
Service Manual Document Number: 995065 
Spare Parts Manual Document Number: 992065 
The Service must be completed every 6 months after installation of the Stand Aid to comply with LOLER Regulations.  

 
The Mackworth SA180 Stand Aid has an expected Service Life of 10 Years. 

 

Contact your local authorised Prism Medical UK dealer if you: 

 

Need more information. 

 

Have any questions about the use or service of your Stand Aid.  

 

Notice any change in the performance. 

 

Want to report an unexpected occurrence. 

 

Want to arrange a service. 

 

Need to ascertain necessary information for replacement parts and components. 
 

Contact details of your local Prism Medical UK dealer are shown on the last page of this manual.

Summary of Contents for SA180

Page 1: ...Doc No 993065 Revision of document A Revision Date 25 05 21 SA180 Stand Aid Pre Sales Document...

Page 2: ...Slings 4 Detachable Parts 5 Attaching detaching the Battery 5 Technical Specification 6 Mackworth SA180 Dimensions 6 Specifications 7 Electrical Specifications 7 Environmental Storage and Operating C...

Page 3: ...gned to support and promote safe patient handling and transfer for both the patient and carer The Stand Aid is one of two components that makes this possible The other component the sling is a special...

Page 4: ...e been approved by Prism Medical UK for use in combination with the product We recommend the use of the Mackworth Healthcare or Care Ability manufactured sling range type B applied part to be utilised...

Page 5: ...ment and detachment of the Battery can be completed safely by following the following procedure Attach 1 Grab Hold of the Battery from the top position as shown in figure 5 and place your fingers onto...

Page 6: ...993065 Revision A P a g e 6 of 12 Technical Specification Mackworth SA180 Dimensions All dimensions below are shown in millimetres Figure 8 Figure 9...

Page 7: ...rical Specifications Battery type 2 x 12 volt Rechargeable sealed lead acid Battery capacity 24 V DC 1 x 2 9 Ah Charger rated input 230VAC 50 60Hz Charger rated output 27 4 29 0 VDC 0 8A Electric Shoc...

Page 8: ...ty is void To ensure the safety and continued good function of your Stand Aid routine service must be performed on your Mackworth SA180 Stand Aid Service should be completed by a Prism Medical UK appr...

Page 9: ...cleaning process Application is through a clean damp cloth applied to wipe the device down Use in the following dilutions to ensure an effective clean Actichlor dissolvable chlorine tablets provide a...

Page 10: ...993065 Revision A P a g e 10 of 12...

Page 11: ...993065 Revision A P a g e 11 of 12...

Page 12: ...UK for any errors or omissions Prism Medical operates a policy of continuous improvement Specifications and other data are subject to change without notice Manufacturer contact details Prism Medical U...

Reviews: