1.5

 

Contraindications/Limitations 

There are no known “contraindications” associated with the usage of the Raiser Transfer Aid, provided they are used as per 

manufacturer’s recommendations and guidelines. However, it is recommended that a client specific assessment is completed by 

a trained and knowledgeable health care professional to determine the method of transfer. 

 

Prism Medical UK does not recommend a required number of care givers for the use of our products. This information and 

recommendation can only be provided after a thorough personalised, case specific assessment, as there are many factors that 

can influence these decisions. 

1.6

 

Intended Use 

For internal use only. 

 

The Mackworth Raiser is a sit to stand platform, which is designed to provide an active, safe and comfortable transfer of the 

user. It is ideal for short distance transfers, such as to/from bed to chair. 

 

Its versatility allows use with wheelchairs, toilet and shower chairs. Soft and wide padding in the leg support improves stability, 

and the sturdy handle offers many grip options for both the user and the carer.  

 

The rear wheels with independent locking manual brakes, makes it easy for a carer to manoeuvre, and provides maximum 

stability and safety for the user. 

 

The Mackworth Raiser has a safe working load of 160 kg

this load must not be exceeded. 

The device is used under instruction, and the operation of the aid is undertaken by a trained carer. 

A risk assessment must be performed before using any other manufactured Transfer Aid, to ensure safe use can be 

established. 

 

The belt(s) is a specially designed fabric accessory that attaches to the Transfer Aid by means of the hooks on the rear face of the 

handle, this holds and aids an individual while the transfer takes place. The sling is supplied separately from the Transfer Aid at 

the initial time of purchase.  

If additional accessories have been supplied with the Transfer aid, refer to the instructions included with those items. 

 

The Transfer Aid: 

 

Helps to assist a user with sit to stand transfers 

 

Maximum user weight: 160 kg  

 

Padded leg support for added comfort 

 

Multiple grip options for both user and carer 

 

Raiser Strap & Safety Belt available to enable a carer to assist a user to their feet 

 

Independent locking rear brakes 

 

 

The Raiser is intended to be installed on a flat and levelled surface prior to use.  

 

 

The Transfer Aid must be installed only by persons authorised by Prism Medical UK or who have the rights to install and 

commission the Transfer Aid safe for use. 

 

 

Under no circumstance should the Raiser be put in control of a person who has not been properly trained in the use 

and care of this equipment. Failure to adhere to this warning may result in serious injury to the operator, and / or the 

individual being transferred. 

 

 

In facilities where more than one operator will be responsible for using the Transfer Aid, it is imperative that all such 

members be trained on the Raiser prior to use. A training program should be established by the facility to acquaint new 

operators with this equipment. 

 

 

The Raiser Transfer Aid, and associated belts are not toys.

 

Do not use it for unsafe practices. Do not allow children to 

play with the Aid or any of its components. The Raiser should not be used for any practice except its intended use. 

Summary of Contents for Raiser

Page 1: ...Doc No 999061 Revision of document A Revision Date 19 04 21 Raiser Transfer Aid User Manual...

Page 2: ...ciples 11 5 1 Standing a user who requires no assistance 11 5 2 Standing a user who requires assistance with optional Ladder belt 11 5 3 Standing a user who requires assistance with the optional safet...

Page 3: ...ts use a serious incident has occurred please report it to the manufacturer and to your national authority Store this manual with the documents included with the Transfer Aid Contents of this manual a...

Page 4: ...ons before use Caution see instructions for use Manufacturer Safe Working Load represents the maximum load rated for safe operation Packaging indicator This way up Date of manufacture Serial number Pa...

Page 5: ...re safe use can be established The belt s is a specially designed fabric accessory that attaches to the Transfer Aid by means of the hooks on the rear face of the handle this holds and aids an individ...

Page 6: ...ce be tampered with Between Transfer Aid and Belt the lowest maximum load shall always be used You may need to seek specialist advice on how to assist some people with specific moving and handling nee...

Page 7: ...show the contents of the Transfer Aid If you have not received all the components contact Prism Medical UK dealer immediately contact details are provided on the last page of this manual Item Descript...

Page 8: ...within the area of the Transfer Aid The environment in which the Transfer Aid is situated in whilst carrying out a transfer is required to be on a flat surface with no steep inclines 3 2 Unboxing Tra...

Page 9: ...pad height on the raiser in the following way 1 On the rear face of the product release the Knee shin pad from its current location by pulling on the black locking plungers and the same time see Figur...

Page 10: ...h at the same time see figure 13 4 To adjust the individual pads inwards and outwards using your hand slide each pad by pushing inwards or outwards to suit the need for the patient see figure 14 15 4...

Page 11: ...ions to the user telling them to stand whilst they are counterbalancing the raiser 5 Once the user is stood the caregiver may release the brakes with one foot Pull the Mackworth Raiser backwards and t...

Page 12: ...spine and the solid section is place under the user s coccyx 2 Fasten in place using the Velcro straps and adjustable buckle fastening support belt ensure support belt is at maximum length 3 The user...

Page 13: ...EN ISO 10535 before its use The belts with a safe working load of 160kg that can be used with the Mackworth Raiser are shown below in Table 3 complete with product codes For all components the lowest...

Page 14: ...999061 Revision A P a g e 14 of 28 6 0 TECHNICAL SPECIFICATION 6 1 Raiser Dimensions Single Knee Pad Figure 28 Figure 29 Figure 30...

Page 15: ...999061 Revision A P a g e 15 of 28 6 2 Raiser Dimensions Double Knee Pad Figure 31 Figure 32 Figure 33...

Page 16: ...le Double Knee Pad 9 kg Handle 5 5 kg Base 11 5 kg Table 5 Operational Forces Operating Force with 160 kg 100N Operating Force with 0 kg 8N Operation of the Brake 75N Sliding the Knee Pad Up 60N Slidi...

Page 17: ...its life cycle and can no longer perform to its intended use safely the Aid must be decommissioned by an approved Service Engineer The following specifies the importance of correct disposal procedure...

Page 18: ...ler immediately so the Transfer Aid can be checked to ensure proper continued operation Table 8 10 0 GENERAL INSPECTION MAINTANANCE AND CLEANING 10 1 Service No service is to be carried out on the Rai...

Page 19: ...contact your local authorised dealer immediately Examine the sling hooks on the handle bar for excessive wear and sharp edges Handle Assembly Ensure that the Installation of the handle to base is corr...

Page 20: ...dirty device This is also ideal for use after an outbreak of the Norovirus winter vomiting and can be used as a precaution against C Diff It is effective against viruses bacteria spores yeasts and mou...

Page 21: ...heet For a full review of the data please follow the link below http www nhsggc org uk media 236215 msds actichlor plus pdf 11 0 WARRANTY This guarantee does not affect or in any way limit your Statut...

Page 22: ...999061 Revision A P a g e 22 of 28 12 0 SERVICE RECORD HISTORY Complete this section after each service repair inspection and or maintenance...

Page 23: ...999061 Revision A P a g e 23 of 28...

Page 24: ...999061 Revision A P a g e 24 of 28...

Page 25: ...999061 Revision A P a g e 25 of 28...

Page 26: ...999061 Revision A P a g e 26 of 28 User notes...

Page 27: ...999061 Revision A P a g e 27 of 28 User notes...

Page 28: ...or omissions Prism Medical UK operates a policy of continuous improvement Specifications and other data are subject to change without notice Dealer service contact details Manufacturer contact detail...

Reviews: