background image

1.

  Read these instructions.  

2.

  Keep these instructions.

3.

  Heed all warnings.

4.

  Follow all instructions.

5.

  Do not use this apparatus near water.

6.

  Clean only with a dry cloth.

7.

  Do not block any ventilation openings. Install in accordance with the 

manufacturer’s instructions.

8.

  Do not install near any heat sources such as radiators, heat registers, 

stoves, or other apparatus (including amplifiers) that produce heat.

9.

  Do not defeat the safety purpose of the polarized or grounding-type 

plug. A polarized plug has two blades with one wider than the other. 

A grounding-type plug has two blades and a third grounding prong. 

The wide blade or the third prong are provided for your safety. If the 

provided plug does not fit into your outlet, consult an electrician for 

replacement of the obsolete outlet.

10.

 Do not overload wall outlets and extension cords as this can result in a 

risk of fire or electric shock.

11.

 Protect the power cord from being walked on or pinched particularly at 

plugs, convenience receptacles, and the point where they exit from the 

apparatus.

12.

 Only use attachments/accessories specified by the manufacturer.

13.

 Use only with a cart, stand, tripod, bracket, or 

table specified by the manufacturer, or sold with 

the apparatus. When a cart is used, use caution 

when moving the cart/apparatus combination to 

avoid injury from tip-over.

14.

 Unplug this apparatus during lightning storms or 

when unused for long periods of time.

15.

 Refer all servicing to qualified service personnel. Servicing is required 

when the apparatus has been damaged in any way, such as power-

supply cord or plug is damaged, liquid has been spilled or objects have 

fallen into the apparatus, the apparatus has been exposed to rain or 

moisture, does not operate normally, or has been dropped.

16.

 This apparatus shall not be exposed to dripping or splashing, and no 

object filled with liquids, such as vases or beer glasses, shall be placed 

on the apparatus.

17.

 This apparatus has been designed with Class-I construction and must 

be connected to a mains socket outlet with a protective earthing con-

nection (the third grounding prong).

18.  

The MAINS plug or an appliance coupler is used as the disconnect 

device, so the disconnect device shall remain readily operable.

19.

 NOTE: This equipment has been tested and found to comply with 

the limits for a Class B digital device, pursuant to part 15 of the FCC 

Rules. These limits are designed to provide reasonable protection 

against harmful interference in a residential installation. This equip-

ment generates, uses, and can radiate radio frequency energy and, if 

not installed and used in accordance with the instructions, may cause 

harmful interference to radio communications. However, there is no 

guarantee that interference will not occur in a particular installation. If 

this equipment does cause harmful interference to radio or television 

reception, which can be determined by turning the equipment off and 

on, the user is encouraged to try to correct the interference by one or 

more of the following measures:

•  Reorient or relocate the receiving antenna.

•  Increase the separation between the equipment and the 

receiver.

•  Connect the equipment into an outlet on a circuit different from 

that to which the receiver is connected.

•  Consult the dealer or an experienced radio/TV technician for 

help.

  CAUTION: Changes or modifications to this device not expressly 

approved by LOUD Technologies Inc. could void the user's authority to 

operate the equipment under FCC rules.

20.

 This apparatus does not exceed the Class A/Class B (whichever is 

applicable) limits for radio noise emissions from digital apparatus as 

set out in the radio interference regulations of the Canadian Department 

of Communications.

ATTENTION

 — 

Le présent appareil numérique n’émet pas de bruits 

radioélectriques dépassant las limites applicables aux appareils 

numériques de class A/de class B (selon le cas) prescrites dans le 

réglement sur le brouillage radioélectrique édicté par les ministere des 

communications du Canada.

21.

 Exposure to extremely high noise levels may cause permanent hearing 

loss. Individuals vary considerably in susceptibility to noise-induced 

hearing loss, but nearly everyone will lose some hearing if exposed to 

sufficiently intense noise for a period of time. The U.S. Government’s 

Occupational Safety and Health Administration (OSHA) has specified 

the permissible noise level exposures shown in the following chart.

  According to OSHA, any exposure in excess of these permissible limits 

could result in some hearing loss. To ensure against potentially danger-

ous exposure to high sound pressure levels, it is recommended that all 

persons exposed to equipment capable of producing high sound pres-

sure levels use hearing protectors while the equipment is in operation. 

Ear plugs or protectors in the ear canals or over the ears must be worn 

when operating the equipment in order to prevent permanent hearing 

loss if exposure is in excess of the limits set forth here:

Important Safety Instructions

PORTABLE CART

WARNING

CAUTION    

AVIS

RISK OF ELECTRIC 

SHOCK. DO NOT OPEN

RISQUE DE CHOC ELECTRIQUE. NE PAS OUVRIR

CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER (OR BACK)

NO USER-SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED PERSONNEL

ATTENTION: POUR EVITER LES RISQUES DE CHOC ELECTRIQUE, NE PAS ENLEVER LE COUVERCLE. 

AUCUN ENTRETIEN DE PIECES INTERIEURES PAR L'USAGER. 

CONFIER L'ENTRETIEN AU PERSONNEL QUALIFIE.

AVIS: POUR EVITER LES RISQUES D'INCENDIE OU D'ELECTROCUTION, N'EXPOSEZ PAS CET ARTICLE 

A LA PLUIE OU A L'HUMIDITE

The lightning flash with arrowhead symbol within an equilateral triangle is 
intended to alert the user to the presence of uninsulated "dangerous 
voltage" within the product's enclosure, that may be of sufficient magnitude 
to constitute a risk of electric shock to persons.

Le symbole éclair avec point de flèche à l'intérieur d'un triangle équilatéral 
est utilisé pour alerter l'utilisateur de la présence à l'intérieur du coffret de 
"voltage dangereux" non isolé d'ampleur suffisante pour constituer un risque 
d'éléctrocution.

The exclamation point within an equilateral triangle is intended to alert the 
user of the presence of important operating and maintenance (servicing) 
instructions in the literature accompanying the appliance.

Le point d'exclamation à l'intérieur d'un triangle équilatéral est employé 
pour alerter les utilisateurs de la présence d'instructions importantes pour le 
fonctionnement et l'entretien (service) dans le livret d'instruction 
accompagnant l'appareil.

WARNING — To reduce the risk of fire or electric shock, do not 

expose this apparatus to rain or moisture.

Duration, 

per day in 

hours

Sound Level 

dBA, Slow 

Response

Typical Example 

8

90

Duo in small club

6

92

4

95

Subway Train

3

97

2

100

Very loud classical music

1.5

102

1

105

Steve screaming at Troy about 

deadlines

0.5 

110

0.25 or less 115

Loudest parts at a rock concert

HD151

HD15

21

Summary of Contents for HD1521

Page 1: ...HD1521 OWNER S MANUAL 2 Way High Definition Powered Loudspeaker...

Page 2: ...evice not expressly approved by LOUD Technologies Inc could void the user s authority to operate the equipment under FCC rules 20 This apparatus does not exceed the Class A Class B whichever is applic...

Page 3: ...with all applicable federal state and local regula tions We strongly recommend the following rigging system practices Documentation Thoroughly document the mounting rigging design with detailed drawi...

Page 4: ...Full Range Power Cords Power Cords Powered subwoofer plays the low frequencies Powered subwoofer plays the low frequencies Mixer HD1521 reproduces all frequencies above the subwoofer s crossover point...

Page 5: ...the Contour EQ circuit The LED next to the switch will light to indicate that the EQ is on Use this switch to engage or bypass the EQ or toggle it repeatedly while listening carefully to judge the EQ...

Page 6: ...dspeaker make sure that the voltage of your unit listed above the IEC AC receptacle is the same voltage as your local AC mains supply Use only the power cord supplied Also disconnecting the plug s gro...

Page 7: ...ome typical room problems that might arise Avoid placing loudspeakers in the corners of a room Doing so increases the low frequency output and can cause the sound to be muddy and indistinct Avoid plac...

Page 8: ...ng via its fly points NEVER attempt to suspend the HD1521 by its handles Rigging Design Practices Rigging a loudspeaker requires determining 1 The rigging methods and hardware that meet static shock d...

Page 9: ...ns carrying the heat away In order for this convection cooling to work efficiently it is important to provide adequate airspace behind the loudspeaker When positioning the HD1521 we recommend leaving...

Page 10: ...Tech Support department at 1 800 898 3211 Mon day Friday during normal business hours Pacific Time to explain the problem Tech Support will tell you where the nearest factory authorized service cente...

Page 11: ...akers See page 4 for a visual example of daisy chaining There is a limit to how many you can daisy chain together A general rule is to maintain a load impedance ten times or more than the source imped...

Page 12: ...iver sensitivity and amplifier power Measured with pink noise free field at 1 meter before limiting Power Amplifiers Low Frequency Power Amplifier Rated Power 700 watts rms 1400 watts peak Rated THD 0...

Page 13: ...25 in 463 5 mm Rear Width 11 82 in 300 2 mm Depth 18 81 in 477 8 mm Weight 80 lb 36 kg Mounting Methods Floor mount pole mount or fly via 12 integrated M10 mounting points using M10 x 1 5 x 37 mm for...

Page 14: ...1 100 10 1 1 3 Octave Response dB SPL 2 83 V 20 100 1000 20000 110 100 120 70 80 90 Horizontal Vertical Frequency Hz Directivity Index dB Directivity Factor Q 20 100 1000 20000 20 10 1 Frequency Hz Fr...

Page 15: ...he Warranty Period to the Company at www mackie com support or by calling LOUD technical support at 1 800 898 3211 toll free in the U S and Canada during normal business hours Pacific Time excluding w...

Page 16: ...Road NE Woodinville WA 98072 USA United States and Canada 800 898 3211 Europe Asia Central and South America 425 487 4333 Middle East and Africa 31 20 654 4000 Fax 425 487 4337 www mackie com E mail s...

Reviews: