Mackie FR Series M-1400i Specifications Download Page 5

O F   8   P A G E S  

M•1400/M•1400i

High-Current Power Amplifier

O F   8   P A G E S  

M•1400/M•1400i

High-Current Power Amplifier

O F   8   P A G E S  

M•1400/M•1400i

High-Current Power Amplifier

M•1400/M•1400i

High-Current Power Amplifer

O F   8   P A G E S  

5

M•1400/M•1400i Front Panel

M•1400i Rear Panel

M•1400 Rear Panel

OL

–3

–6

–9

–20

–3

–6

–9

–20

SIG

OL

SIG

CH

1

30

28

26

20

22

18

24

16

14

8

0 0

1.23v (+4dBu)

SENSITIVITY

GAIN/dB

CH

2

PROTECT

COLD

HOT

SHORT

TEMP STATUS

INTERNAL  STATUS

CH

1

CH

2

CH 

1& 2

ON

OFF

POWER

3v

2v

1v

30

28

26

20

22

18

24

16

14

8

0 0

1.23v (+4dBu)

SENSITIVITY

GAIN/dB

3v

2v

1v

 PROFESSIONAL POWER AMPLIFIER

FULL SYMMETRY DUAL DIFFERENTIAL  HIGH CURRENT DESIGN

CHANNEL

2

1

CHANNEL

CH

2

SPEAKER OUTPUTS

+

+

63Hz

125Hz

CONSTANT DIRECTIVITY

HORN EQ /AIR EQ

CONSTANT DIRECTIVITY

HORN EQ /AIR EQ

INPUT

THRU

THRU

INPUT

AMP MODE

FREQUENCY

4.5  k Hz

ON

6k Hz

2k Hz

MONO

(CHS SUMMED)

BRIDGE

LIMITER 

(CH1 & CH2)

OFF

FULL 

RANGE

SUB 

WOOFER

LOW CUT

FILTER

LOW CUT

FILTER

OUTPUT APPLICATION

BALANCED

OR

UNBALANCED

BALANCED

OR

UNBALANCED

ON

/ BRIDGE / MONO

170 Hz

OFF

4.5k Hz

6k Hz

2k Hz

+

170 Hz

100 Hz

OFF

STAGE

MONITOR

100 Hz

STAGE

MONITOR

OFF

TYPICAL

ON

OFF

TYPICAL

TYPICAL

35 Hz

STEREO

TYPICAL

STEREO

TYPICAL

AIR EQ

AIR EQ

CH

1

120 VAC 60 Hz 

1000 WATTS

(MONO BRIDGE)

1000 WATTS

8 OHM LOAD

MONO

BRIDGE

(STEREO)

500 W/500 W

4 OHM LOAD

OUTPUTS

SUITABLE

FOR CLASS

2 WIRING

OUTPUTS

SUITABLE

FOR CLASS

2 WIRING

CONCEIVED, DESIGNED, AND MANUFACTURED BY MACKIE DESIGNS INC • WOODINVILLE • WA

98072 • USA • MADE IN USA • FABRIQUE AU USA • PATENTS PENDING • COPYRIGHT ©1997

 THE FOLLOWING ARE TRADEMARKS AND REGISTERED TRADEMARKS OF MACKIE DESIGN INC.: "MACKIE", "FR SERIES", AND THE "RUNNING MAN" FIGURE

MANUFACTURING DATE

RISK OF ELECTRIC SHOCK

DO NOT OPEN

WARNING:

 TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT 

EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE. DO NOT REMOVE COVER. 

NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED PERSONNEL.

AVIS:

 RISQUE DE CHOC ELECTRIQUE — NE PAS OUVRIR

CAUTION

SERIAL NUMBER

TYPICAL

35 Hz

CHANNEL

2

1

CHANNEL

CH

1

CH

2

SPEAKER OUTPUTS

+

+

63Hz

125Hz

CONSTANT DIRECTIVITY

HORN EQ /AIR EQ

CONSTANT DIRECTIVITY

HORN EQ /AIR EQ

INPUT

THRU

THRU

INPUT

AMP MODE

FREQUENCY

4.5  k Hz

ON

6k Hz

2k Hz

MONO

BRIDGE

LIMITER 

(CH1 & CH2)

OFF

FULL 

RANGE

SUB 

WOOFER

LOW CUT

FILTER

LOW CUT

FILTER

OUTPUT APPLICATION

SERIAL NUMBER

MANUFACTURING DATE

RISK OF ELECTRIC SHOCK

DO NOT OPEN

WARNING: 

TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT 

EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE. DO NOT REMOVE COVER. 

NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED PERSONNEL.

CAUTION

AVIS:

 RISCQUE DE CHOC ÉLECTRIQUE — NE PAS OUVRIR

BALANCED

OR

UNBALANCED

BALANCED

OR

UNBALANCED

AIR EQ

MONO

BRIDGE

ON

/ BRIDGE / MONO

170 Hz

OFF

4.5k Hz

6k Hz

2k Hz

AIR EQ

120 VAC 50/60 Hz 

1500 WATTS

+

170 Hz

100 Hz

OFF

STAGE

MONITOR

100 Hz

STAGE

MONITOR

OFF

TYPICAL

ON

OFF

TYPICAL

TYPICAL

35 Hz

TYPICAL

35 Hz

STEREO

TYPICAL

STEREO

TYPICAL

AIR EQ

AIR EQ

CONCEIVED, DESIGNED, AND MANUFACTURED BY MACKIE DESIGNS INC • WOODINVILLE • WA

98072 • USA • MADE IN USA • FABRIQUE AU USA • PATENTS PENDING • COPYRIGHT ©1997

 THE FOLLOWING ARE TRADEMARKS AND REGISTERED TRADEMARKS OF MACKIE DESIGN INC.: "MACKIE", "FR SERIES", AND THE "RUNNING MAN" FIGURE

(MONO BRIDGE)

1000 WATTS

8 OHM LOAD

(STEREO)

500 W / 500 W

4 OHM LOAD

OUTPUTS

SUITABLE

FOR CLASS

2 WIRING

OUTPUTS

SUITABLE

FOR CLASS

2 WIRING

Summary of Contents for FR Series M-1400i

Page 1: ... a number of unique features including FR Fast Recovery design high continuous current output built in subwoofer crossovers and a T Design constant gradient cooling tunnel for improved cooling efficiency and output device reliability The M 1400 M 1400i is rated at a continuous out put of 250 watts per channel into 8Ω 425 watts per channel into 4Ω and 630 watts into 2Ω In bridge mode the M 1400 M 1...

Page 2: ...d bridging Input Sensitivity 1 23 4 dBu for rated power into 4 ohms Voltage Gain 30 25 dB 32 5V V Maximum Input Level 9 75 volts 22 dBu Rise Time 4 4µs Slew Rate Voltage Slew Rate 50V µs 100V µs bridged Current Slew Rate 32A µs at 2Ω CMRR 40 dB 20Hz to 20kHz Transient Recovery 1µs for 20 dB overdrive at 1kHz High Frequency Overload and Latching No latch up to any frequency or level Variable Low Cu...

Page 3: ...Width 19 00 483 mm Depth 15 25 387 mm Overall Depth 16 38 416 mm Weight 36 lbs 16 3 kg OL 3 6 9 20 3 6 9 20 SIG OL SIG CH 1 30 28 26 20 22 18 24 16 14 8 0 0 1 23v 4dBu SENSITIVITY GAIN dB CH 2 PROTECT COLD HOT SHORT TEMP STATUS INTERNAL STATUS CH 1 CH 2 CH 1 2 ON OFF POWER 3v 2v 1v 30 28 26 20 22 18 24 16 14 8 0 0 1 23v 4dBu SENSITIVITY GAIN dB 3v 2v 1v PROFESSIONAL POWER AMPLIFIER FULL SYMMETRY D...

Page 4: ...CT LED POWER AMPLIFIER FUSE 80VDC FUSE 80VDC DC OFFSET DETECT SHORT DETECT METER DRIVE POWER AMPLIFIER FUSE 80VDC FUSE 80VDC DC OFFSET DETECT TO CH 1 MUTE OL 3 6 9 20 SIG CH 1 SIG CH 2 SHORT LED SHORT DETECT METER DRIVE TO CH 2 MUTE TO CH 1 MUTE TO CH 2 MUTE OL 3 6 9 20 SIG CH 2 SIG SIG TO CH 1 METER DRIVE SIG TO CH 2 METER DRIVE PD s LEASH HOT LED COLD LED TEMP SENSOR ON HEATSINK FROM CH 1 SHORT ...

Page 5: ...FIGURE MANUFACTURING DATE RISK OF ELECTRIC SHOCK DO NOT OPEN WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE DO NOT REMOVE COVER NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED PERSONNEL AVIS RISQUE DE CHOC ELECTRIQUE NE PAS OUVRIR CAUTION SERIAL NUMBER TYPICAL 35 Hz CHANNEL 2 1 CHANNEL CH 1 CH 2 SPEAKER OUTPUTS 63Hz 125Hz CONSTAN...

Page 6: ... signal present 20 dB 9 dB 6 dB 3 dB and overload Each chan nel shall have internal status LEDs appearing on the front panel to indicate activation of protect mode and short cir cuit protection Two temperature status LEDs shall appear on the front panel one to indicate normal operation COLD and one to indicate thermal protection HOT 7 PROTECTION FEATURES The amplifier shall pro vide delayed activa...

Page 7: ...n the rear panel covering a range of 10Hz OFF to 170Hz 12 CONSTANT DIRECTIVITY HORN EQ Each chan nel shall have a two way switch appearing on the rear panel for selecting a constant directivity horn equaliza tion circuit When selected this circuit shall provide a 6 dB per octave high frequency boost The EQ shall have a variable frequency control appearing on the rear panel covering a range of 2kHz...

Page 8: ...witch selects the cutoff fre quency of the filter at either 63Hz or 125Hz 8 Electronic files for this product available at www mackie com This Specification Sheet M1400_SS PDF Owner Operator s Manual M1400_OM PDF LOUD Technologies continually engages in research related to product improvement New material production methods and design refinements are introduced into existing products without notic...

Reviews: